These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 19151521)

  • 1. [Simultaneous collection of SWI and MRA images by 3T-MRI].
    Matsui H; Horinouchi T; Ohnishi T; Kumatani Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2008 Dec; 64(12):1522-31. PubMed ID: 19151521
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous imaging of radiation-induced cerebral microbleeds, arteries and veins, using a multiple gradient echo sequence at 7 Tesla.
    Bian W; Banerjee S; Kelly DA; Hess CP; Larson PE; Chang SM; Nelson SJ; Lupo JM
    J Magn Reson Imaging; 2015 Aug; 42(2):269-79. PubMed ID: 25471321
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An interleaved sequence for simultaneous magnetic resonance angiography (MRA), susceptibility weighted imaging (SWI) and quantitative susceptibility mapping (QSM).
    Chen Y; Liu S; Buch S; Hu J; Kang Y; Haacke EM
    Magn Reson Imaging; 2018 Apr; 47():1-6. PubMed ID: 29154893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Susceptibility-weighted imaging and magnetic resonance angiography during migraine attack: a case report.
    Shimoda Y; Kudo K; Kuroda S; Zaitsu Y; Fujima N; Terae S; Sasaki M; Houkin K
    Magn Reson Med Sci; 2011; 10(1):49-52. PubMed ID: 21441728
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A fully flow-compensated multiecho susceptibility-weighted imaging sequence: The effects of acceleration and background field on flow compensation.
    Wu D; Liu S; Buch S; Ye Y; Dai Y; Haacke EM
    Magn Reson Med; 2016 Aug; 76(2):478-89. PubMed ID: 26332053
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dual-echo arteriovenography imaging with 7T MRI.
    Bae KT; Park SH; Moon CH; Kim JH; Kaya D; Zhao T
    J Magn Reson Imaging; 2010 Jan; 31(1):255-61. PubMed ID: 20027596
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noncontrast-enhanced magnetic resonance angiography and venography imaging with enhanced angiography.
    Ye Y; Hu J; Wu D; Haacke EM
    J Magn Reson Imaging; 2013 Dec; 38(6):1539-48. PubMed ID: 23559486
    [TBL] [Abstract][Full Text] [Related]  

  • 8. ToF-SWI: simultaneous time of flight and fully flow compensated susceptibility weighted imaging.
    Deistung A; Dittrich E; Sedlacik J; Rauscher A; Reichenbach JR
    J Magn Reson Imaging; 2009 Jun; 29(6):1478-84. PubMed ID: 19472425
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Short T2 tissue imaging with the Pointwise Encoding Time reduction with Radial Acquisition (PETRA) sequence: the additional value of fat saturation and subtraction in the meniscus.
    Lee YH; Suh JS; Grodzki D
    Magn Reson Imaging; 2015 May; 33(4):385-9. PubMed ID: 25614216
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of susceptibility-weighted and perfusion-weighted magnetic resonance imaging in the detection of penumbra in acute ischemic stroke.
    Luo S; Yang L; Wang L
    J Neuroradiol; 2015 Oct; 42(5):255-60. PubMed ID: 25451668
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrashort echo (UTE) versus pointwise encoding time reduction with radial acquisition (PETRA) sequences at 3 Tesla for knee meniscus: A comparative study.
    Lee YH; Suh JS; Grodzki D
    Magn Reson Imaging; 2016 Feb; 34(2):75-80. PubMed ID: 26435460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cerebral artery segmentation based on magnetization-prepared two rapid acquisition gradient echo multi-contrast images in 7 Tesla magnetic resonance imaging.
    Choi US; Kawaguchi H; Kida I
    Neuroimage; 2020 Nov; 222():117259. PubMed ID: 32798680
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous Variable-Slab Dual-Echo TOF MR Angiography and Susceptibility-Weighted Imaging.
    Do WJ; Choi SH; Park SH
    IEEE Trans Med Imaging; 2018 Jul; 37(7):1632-1640. PubMed ID: 29969414
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nonenhanced magnetic resonance angiography of the lower extremity vessels at 7 tesla: initial experience.
    Fischer A; Maderwald S; Orzada S; Johst S; Schäfer LC; Ladd ME; Nassenstein K; Umutlu L; Lauenstein TC
    Invest Radiol; 2013 Jul; 48(7):525-34. PubMed ID: 23493120
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous time-of-flight MR angiography and quantitative susceptibility mapping with key time-of-flight features.
    De A; Grenier J; Wilman AH
    NMR Biomed; 2024 Apr; 37(4):e5079. PubMed ID: 38054247
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High spatial resolution and high contrast visualization of brain arteries and veins: impact of blood pool contrast agent and water-selective excitation imaging at 3T.
    Spuentrup E; Jacobs JE; Kleimann JF; Wiethoff AJ; Poggenborg J; Brinker G; Loehr M; Möller-Hartmann W; Botnar RM; Ernestus RI; Lackner KJ
    Rofo; 2010 Dec; 182(12):1097-104. PubMed ID: 20803412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Susceptibility weighted imaging and quantitative susceptibility mapping of the cerebral vasculature using ferumoxytol.
    Liu S; Brisset JC; Hu J; Haacke EM; Ge Y
    J Magn Reson Imaging; 2018 Mar; 47(3):621-633. PubMed ID: 28731570
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved visualization of intracranial vessels by gradient moment nulling in hybrid of opposite-contrast magnetic resonance angiography (HOP MRA).
    Azuma T; Kodama T; Yano T; Suzuki M; Kimura T; Tamaribuchi Y
    Magn Reson Med Sci; 2010; 9(3):159-65. PubMed ID: 20885090
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hybrid of opposite-contrast MR angiography (HOP-MRA) combining time-of-flight and flow-sensitive black-blood contrasts.
    Kimura T; Ikedo M; Takemoto S
    Magn Reson Med; 2009 Aug; 62(2):450-8. PubMed ID: 19526496
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Susceptibility-weighted angiography (SWAN) of cerebral veins and arteries compared to TOF-MRA.
    Boeckh-Behrens T; Lutz J; Lummel N; Burke M; Wesemann T; Schöpf V; Brückmann H; Linn J
    Eur J Radiol; 2012 Jun; 81(6):1238-45. PubMed ID: 21466929
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.