1. Effect of calibration method on Tekscan sensor accuracy. Brimacombe JM; Wilson DR; Hodgson AJ; Ho KC; Anglin C J Biomech Eng; 2009 Mar; 131(3):034503. PubMed ID: 19154074 [TBL] [Abstract][Full Text] [Related]
2. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine. Wilson DC; Niosi CA; Zhu QA; Oxland TR; Wilson DR J Biomech; 2006; 39(2):348-53. PubMed ID: 16321637 [TBL] [Abstract][Full Text] [Related]
3. Accuracy of circular contact area measurements with thin-film pressure sensors. Drewniak EI; Crisco JJ; Spenciner DB; Fleming BC J Biomech; 2007; 40(11):2569-72. PubMed ID: 17270193 [TBL] [Abstract][Full Text] [Related]
4. Comparison of capacitive versus resistive joint contact stress sensors. Martinelli L; Hurschler C; Rosenbaum D Clin Orthop Relat Res; 2006 Jun; 447():214-20. PubMed ID: 16672899 [TBL] [Abstract][Full Text] [Related]
5. Characterization and application of thin film pressure sensors. Valdevit A; Ortega-Garcia J; Kambic H; Kuroda R; Elster T; Parker RD Biomed Mater Eng; 1999; 9(2):81-8. PubMed ID: 10524291 [TBL] [Abstract][Full Text] [Related]
7. [Measuring plantar pressure in conventional shoes with the TEKSCAN sensory system]. Koch M Biomed Tech (Berl); 1993 Oct; 38(10):243-8. PubMed ID: 8268402 [TBL] [Abstract][Full Text] [Related]
8. Optical calibration for both out-of-plane and in-plane displacement sensitivity of acoustic emission sensors. Theobald PD Ultrasonics; 2009 Dec; 49(8):623-7. PubMed ID: 19409592 [TBL] [Abstract][Full Text] [Related]
9. A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force. Hall RS; Desmoulin GT; Milner TE J Biomech; 2008 Dec; 41(16):3492-5. PubMed ID: 19019374 [TBL] [Abstract][Full Text] [Related]
10. Validation of F-Scan pressure sensor system: a technical note. Luo ZP; Berglund LJ; An KN J Rehabil Res Dev; 1998 Jun; 35(2):186-91. PubMed ID: 9651890 [TBL] [Abstract][Full Text] [Related]
11. Measuring contact area, force, and pressure for bioengineering applications: using Fuji Film and TekScan systems. Bachus KN; DeMarco AL; Judd KT; Horwitz DS; Brodke DS Med Eng Phys; 2006 Jun; 28(5):483-8. PubMed ID: 16181797 [TBL] [Abstract][Full Text] [Related]
12. Total hip joint prosthesis for in vivo measurement of forces and moments. Damm P; Graichen F; Rohlmann A; Bender A; Bergmann G Med Eng Phys; 2010 Jan; 32(1):95-100. PubMed ID: 19889565 [TBL] [Abstract][Full Text] [Related]
13. Calibration of measured center of pressure of a new stairway design for kinetic analysis of stair climbing. Yu B; Growney ES; Schultz FM; An KN J Biomech; 1996 Dec; 29(12):1625-8. PubMed ID: 8945662 [TBL] [Abstract][Full Text] [Related]
15. Biosensor system for continuous glucose monitoring in fish. Yonemori Y; Takahashi E; Ren H; Hayashi T; Endo H Anal Chim Acta; 2009 Feb; 633(1):90-6. PubMed ID: 19110121 [TBL] [Abstract][Full Text] [Related]
16. The identification of vertical velocity profiles using an inertial sensor to investigate pre-impact detection of falls. Bourke AK; O'Donovan KJ; Olaighin G Med Eng Phys; 2008 Sep; 30(7):937-46. PubMed ID: 18243034 [TBL] [Abstract][Full Text] [Related]
17. A technique to measure eyelid pressure using piezoresistive sensors. Shaw AJ; Davis BA; Collins MJ; Carney LG IEEE Trans Biomed Eng; 2009 Oct; 56(10):2512-7. PubMed ID: 19457740 [TBL] [Abstract][Full Text] [Related]
18. Calibration of an ingestible temperature sensor. Hunt AP; Stewart IB Physiol Meas; 2008 Nov; 29(11):N71-8. PubMed ID: 18843163 [TBL] [Abstract][Full Text] [Related]
19. Mass transfer and gas-phase calibration of implanted oxygen sensors. Makale MT; Jablecki MC; Gough DA Anal Chem; 2004 Mar; 76(6):1773-7. PubMed ID: 15018582 [TBL] [Abstract][Full Text] [Related]
20. Characterization of a heat flux sensor using short pulse laser calibration. Löhle S; Battaglia JL; Batsale JC; Enouf O; Dubard J; Filtz JR Rev Sci Instrum; 2007 May; 78(5):053501. PubMed ID: 17552814 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]