311 related articles for article (PubMed ID: 19154076)
1. Design and evaluation of a new general-purpose device for calibrating instrumented spatial linkages.
Nordquist JA; Hull ML
J Biomech Eng; 2009 Mar; 131(3):034505. PubMed ID: 19154076
[TBL] [Abstract][Full Text] [Related]
2. Design and demonstration of a new instrumented spatial linkage for use in a dynamic environment: application to measurement of ankle rotations during snowboarding.
Nordquist J; Hull ML
J Biomech Eng; 2007 Apr; 129(2):231-9. PubMed ID: 17408328
[TBL] [Abstract][Full Text] [Related]
3. Design, calibration and validation of a novel 3D printed instrumented spatial linkage that measures changes in the rotational axes of the tibiofemoral joint.
Bonny DP; Hull ML; Howell SM
J Biomech Eng; 2014 Jan; 136(1):011003. PubMed ID: 24064860
[TBL] [Abstract][Full Text] [Related]
4. Optimized design of an instrumented spatial linkage that minimizes errors in locating the rotational axes of the tibiofemoral joint: a computational analysis.
Bonny DP; Hull ML; Howell SM
J Biomech Eng; 2013 Mar; 135(3):31003. PubMed ID: 24231814
[TBL] [Abstract][Full Text] [Related]
5. 6R instrumented spatial linkages for anatomical joint motion measurement--Part 2: Calibration.
Kirstukas SJ; Lewis JL; Erdman AG
J Biomech Eng; 1992 Feb; 114(1):101-10. PubMed ID: 1491572
[TBL] [Abstract][Full Text] [Related]
6. Calibration and validation of 6 DOFs instrumented spatial linkage for biomechanical applications. A practical approach.
Sholukha V; Salvia P; Hilal I; Feipel V; Rooze M; Jan SV
Med Eng Phys; 2004 Apr; 26(3):251-60. PubMed ID: 14984847
[TBL] [Abstract][Full Text] [Related]
7. An instrumented spatial linkage for measuring knee joint kinematics.
Rosvold JM; Atarod M; Frank CB; Shrive NG
Knee; 2016 Jan; 23(1):43-8. PubMed ID: 26471425
[TBL] [Abstract][Full Text] [Related]
8. Calibration of measured center of pressure of a new stairway design for kinetic analysis of stair climbing.
Yu B; Growney ES; Schultz FM; An KN
J Biomech; 1996 Dec; 29(12):1625-8. PubMed ID: 8945662
[TBL] [Abstract][Full Text] [Related]
9. Method of rotation angle measurement in machine vision based on calibration pattern with spot array.
Li W; Jin J; Li X; Li B
Appl Opt; 2010 Feb; 49(6):1001-6. PubMed ID: 20174168
[TBL] [Abstract][Full Text] [Related]
10. 6R instrumented spatial linkages for anatomical joint motion measurement--Part 1: Design.
Kirstukas SJ; Lewis JL; Erdman AG
J Biomech Eng; 1992 Feb; 114(1):92-100. PubMed ID: 1491592
[TBL] [Abstract][Full Text] [Related]
11. An ultrasonic device for source to skin surface distance measurement in patient setup.
Feng Y; Allison R; Hu XH; Mota H; Jenkins T; Wolfe ML; Sibata C
Int J Radiat Oncol Biol Phys; 2005 Apr; 61(5):1587-9. PubMed ID: 15817366
[TBL] [Abstract][Full Text] [Related]
12. Validation of a calibration technique for 6-DOF instrumented spatial linkages.
Gatti G; Danieli G
J Biomech; 2007; 40(7):1455-66. PubMed ID: 16935290
[TBL] [Abstract][Full Text] [Related]
13. A comparison of calibration methods for stereo fluoroscopic imaging systems.
Kaptein BL; Shelburne KB; Torry MR; Giphart JE
J Biomech; 2011 Sep; 44(13):2511-5. PubMed ID: 21783196
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of an optical active-marker system to track the relative motion of rigid bodies.
Maletsky LP; Sun J; Morton NA
J Biomech; 2007; 40(3):682-5. PubMed ID: 16580000
[TBL] [Abstract][Full Text] [Related]
15. The static accuracy and calibration of inertial measurement units for 3D orientation.
Brodie MA; Walmsley A; Page W
Comput Methods Biomech Biomed Engin; 2008 Dec; 11(6):641-8. PubMed ID: 18688763
[TBL] [Abstract][Full Text] [Related]
16. A needle tracking device for ultrasound guided percutaneous procedures.
Chan C; Lam F; Rohling R
Ultrasound Med Biol; 2005 Nov; 31(11):1469-83. PubMed ID: 16286026
[TBL] [Abstract][Full Text] [Related]
17. Effect of calibration method on Tekscan sensor accuracy.
Brimacombe JM; Wilson DR; Hodgson AJ; Ho KC; Anglin C
J Biomech Eng; 2009 Mar; 131(3):034503. PubMed ID: 19154074
[TBL] [Abstract][Full Text] [Related]
18. Design and calibration of load sensing orthopaedic implants.
Bergmann G; Graichen F; Rohlmann A; Westerhoff P; Heinlein B; Bender A; Ehrig R
J Biomech Eng; 2008 Apr; 130(2):021009. PubMed ID: 18412496
[TBL] [Abstract][Full Text] [Related]
19. Improving net joint torque calculations through a two-step optimization method for estimating body segment parameters.
Riemer R; Hsiao-Wecksler ET
J Biomech Eng; 2009 Jan; 131(1):011007. PubMed ID: 19045923
[TBL] [Abstract][Full Text] [Related]
20. Design and preliminary evaluation of a portable device for the measurement of bioimpedance spectroscopy.
Yang Y; Wang J; Yu G; Niu F; He P
Physiol Meas; 2006 Dec; 27(12):1293-310. PubMed ID: 17135701
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]