819 related articles for article (PubMed ID: 19156808)
1. A ratiometric fluorescent probe for hypochlorite based on a deoximation reaction.
Lin W; Long L; Chen B; Tan W
Chemistry; 2009; 15(10):2305-9. PubMed ID: 19156808
[TBL] [Abstract][Full Text] [Related]
2. A highly selective and sensitive fluorescence probe for the hypochlorite anion.
Chen X; Wang X; Wang S; Shi W; Wang K; Ma H
Chemistry; 2008; 14(15):4719-24. PubMed ID: 18386284
[TBL] [Abstract][Full Text] [Related]
3. Development of an ICT-based ratiometric fluorescent hypochlorite probe suitable for living cell imaging.
Yuan L; Lin W; Song J; Yang Y
Chem Commun (Camb); 2011 Dec; 47(47):12691-3. PubMed ID: 22037995
[TBL] [Abstract][Full Text] [Related]
4. Construction of a ratiometric fluorescent probe with an extremely large emission shift for imaging hypochlorite in living cells.
Song X; Dong B; Kong X; Wang C; Zhang N; Lin W
Spectrochim Acta A Mol Biomol Spectrosc; 2018 Jan; 188():394-399. PubMed ID: 28755637
[TBL] [Abstract][Full Text] [Related]
5. Construction of fluorescent probes via protection/deprotection of functional groups: a ratiometric fluorescent probe for Cu2+.
Lin W; Yuan L; Tan W; Feng J; Long L
Chemistry; 2009; 15(4):1030-5. PubMed ID: 19053103
[TBL] [Abstract][Full Text] [Related]
6. A highly selective fluorescent probe for hypochlorite and its endogenous imaging in living cells.
Reja SI; Bhalla V; Sharma A; Kaur G; Kumar M
Chem Commun (Camb); 2014 Oct; 50(80):11911-4. PubMed ID: 25155881
[TBL] [Abstract][Full Text] [Related]
7. Atom arrangement strategy for designing a turn-on 1H magnetic resonance probe: a dual activatable probe for multimodal detection of hypochlorite.
Doura T; Nonaka H; Sando S
Chem Commun (Camb); 2012 Feb; 48(10):1565-7. PubMed ID: 21584328
[TBL] [Abstract][Full Text] [Related]
8. A highly specific BODIPY-based fluorescent probe for the detection of hypochlorous acid.
Sun ZN; Liu FQ; Chen Y; Tam PK; Yang D
Org Lett; 2008 Jun; 10(11):2171-4. PubMed ID: 18447382
[TBL] [Abstract][Full Text] [Related]
9. Rapid and visual detection for hypochlorite of an AIE enhanced fluorescence probe.
Cheng HR; Ji Y; Liu F; Lu XJ
Luminescence; 2019 Dec; 34(8):903-910. PubMed ID: 31364263
[TBL] [Abstract][Full Text] [Related]
10. A strategy for highly selective detection and imaging of hypochlorite using selenoxide elimination.
Li G; Zhu D; Liu Q; Xue L; Jiang H
Org Lett; 2013 Apr; 15(8):2002-5. PubMed ID: 23570441
[TBL] [Abstract][Full Text] [Related]
11. A ratiometric fluorescent viscosity sensor.
Haidekker MA; Brady TP; Lichlyter D; Theodorakis EA
J Am Chem Soc; 2006 Jan; 128(2):398-9. PubMed ID: 16402812
[TBL] [Abstract][Full Text] [Related]
12. Development of a highly specific rhodamine-based fluorescence probe for hypochlorous acid and its application to real-time imaging of phagocytosis.
Kenmoku S; Urano Y; Kojima H; Nagano T
J Am Chem Soc; 2007 Jun; 129(23):7313-8. PubMed ID: 17506554
[TBL] [Abstract][Full Text] [Related]
13. A novel ratiometric fluorescent Fe3+ sensor based on a phenanthroimidazole chromophore.
Lin W; Long L; Yuan L; Cao Z; Feng J
Anal Chim Acta; 2009 Feb; 634(2):262-6. PubMed ID: 19185130
[TBL] [Abstract][Full Text] [Related]
14. FRET spectral unmixing: a ratiometric fluorescent nanoprobe for hypochlorite.
Chen G; Song F; Wang J; Yang Z; Sun S; Fan J; Qiang X; Wang X; Dou B; Peng X
Chem Commun (Camb); 2012 Mar; 48(24):2949-51. PubMed ID: 22237551
[TBL] [Abstract][Full Text] [Related]
15. Fluorescence Quenching-Based Mechanism for Determination of Hypochlorite by Coumarin-Derived Sensors.
Starzak K; Matwijczuk A; Creaven B; Matwijczuk A; Wybraniec S; Karcz D
Int J Mol Sci; 2019 Jan; 20(2):. PubMed ID: 30642004
[TBL] [Abstract][Full Text] [Related]
16. A "turn-on" fluorescent probe for hypochlorous acid: convenient synthesis, good sensing performance, and a new design strategy by the removal of C=N isomerization.
Cheng X; Jia H; Long T; Feng J; Qin J; Li Z
Chem Commun (Camb); 2011 Nov; 47(43):11978-80. PubMed ID: 21959955
[TBL] [Abstract][Full Text] [Related]
17. Hypochlorous acid turn-on fluorescent probe based on oxidation of diphenyl selenide.
Liu SR; Wu SP
Org Lett; 2013 Feb; 15(4):878-81. PubMed ID: 23373559
[TBL] [Abstract][Full Text] [Related]
18. A high-resolution mitochondria-targeting ratiometric fluorescent probe for detection of the endogenous hypochlorous acid.
Zhou L; Lu DQ; Wang Q; Hu S; Wang H; Sun H; Zhang X
Spectrochim Acta A Mol Biomol Spectrosc; 2016 Sep; 166():129-134. PubMed ID: 27236136
[TBL] [Abstract][Full Text] [Related]
19. A ratiometric fluorescent probe for sensing HOCl based on a coumarin-rhodamine dyad.
Zhang YR; Chen XP; Jing-Shao ; Zhang JY; Yuan Q; Miao JY; Zhao BX
Chem Commun (Camb); 2014 Nov; 50(91):14241-4. PubMed ID: 25283359
[TBL] [Abstract][Full Text] [Related]
20. A ratiometric fluorescent probe for in situ quantification of basal mitochondrial hypochlorite in cancer cells.
Hou JT; Li K; Yang J; Yu KK; Liao YX; Ran YZ; Liu YH; Zhou XD; Yu XQ
Chem Commun (Camb); 2015 Apr; 51(31):6781-4. PubMed ID: 25785927
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]