585 related articles for article (PubMed ID: 19157888)
21. 3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).
Drobne D
Methods Mol Biol; 2013; 950():275-92. PubMed ID: 23086881
[TBL] [Abstract][Full Text] [Related]
22. Surface damage induced by FIB milling and imaging of biological samples is controllable.
Drobne D; Milani M; Leser V; Tatti F
Microsc Res Tech; 2007 Oct; 70(10):895-903. PubMed ID: 17661360
[TBL] [Abstract][Full Text] [Related]
23. Damage in III-V compounds during focused ion beam milling.
Rubanov S; Munroe PR
Microsc Microanal; 2005 Oct; 11(5):446-55. PubMed ID: 17481325
[TBL] [Abstract][Full Text] [Related]
24. Comparison of different preparation methods of biological samples for FIB milling and SEM investigation.
Leser V; Drobne D; Pipan Z; Milani M; Tatti F
J Microsc; 2009 Feb; 233(2):309-19. PubMed ID: 19220697
[TBL] [Abstract][Full Text] [Related]
25. Site-specific specimen preparation by focused ion beam milling for transmission electron microscopy of metal matrix composites.
Gasser P; Klotz UE; Khalid FA; Beffort O
Microsc Microanal; 2004 Apr; 10(2):311-6. PubMed ID: 15306057
[TBL] [Abstract][Full Text] [Related]
26. Analysis of early hard tissue formation in dentine by energy dispersive X-ray microanalysis and energy-filtering transmission electron microscopy.
Wiesmann HP; Plate U; Höhling HJ; Barckhaus RH; Zierold K
Scanning Microsc; 1993 Jun; 7(2):711-8. PubMed ID: 8108683
[TBL] [Abstract][Full Text] [Related]
27. Investigation of dentinal tubule occlusion using FIB-SEM milling and EDX.
Earl JS; Ward MB; Langford RM
J Clin Dent; 2010; 21(2):37-41. PubMed ID: 20669814
[TBL] [Abstract][Full Text] [Related]
28. Off-axis electron holography of unbiased and reverse-biased focused ion beam milled Si p-n junctions.
Twitchett AC; Dunin-Borkowski RE; Hallifax RJ; Broom RF; Midgley PA
Microsc Microanal; 2005 Feb; 11(1):66-78. PubMed ID: 15683573
[TBL] [Abstract][Full Text] [Related]
29. Off-axis electron holography of electrostatic potentials in unbiased and reverse biased focused ion beam milled semiconductor devices.
Twitchett AC; Dunin-Borkowski RE; Hallifax RJ; Broom RF; Midgley PA
J Microsc; 2004 Jun; 214(Pt 3):287-96. PubMed ID: 15157196
[TBL] [Abstract][Full Text] [Related]
30. TEM sample preparation by FIB for carbon nanotube interconnects.
Ke X; Bals S; Romo Negreira A; Hantschel T; Bender H; Van Tendeloo G
Ultramicroscopy; 2009 Oct; 109(11):1353-9. PubMed ID: 19665846
[TBL] [Abstract][Full Text] [Related]
31. The application of FIB milling for specimen preparation from crystalline germanium.
Rubanov S; Munroe PR
Micron; 2004; 35(7):549-56. PubMed ID: 15219901
[TBL] [Abstract][Full Text] [Related]
32. Matrix-mediated biomineralization in marine mollusks: a combined transmission electron microscopy and focused ion beam approach.
Saunders M; Kong C; Shaw JA; Clode PL
Microsc Microanal; 2011 Apr; 17(2):220-5. PubMed ID: 21371372
[TBL] [Abstract][Full Text] [Related]
33. Cross-sectional sample preparation by focused ion beam: a review of ion-sample interaction.
Ishitani T; Yaguchi T
Microsc Res Tech; 1996 Nov; 35(4):320-33. PubMed ID: 8987026
[TBL] [Abstract][Full Text] [Related]
34. In situ hydride formation in titanium during focused ion milling.
Ding R; Jones IP
J Electron Microsc (Tokyo); 2011; 60(1):1-9. PubMed ID: 20871111
[TBL] [Abstract][Full Text] [Related]
35. Improved focused ion beam target preparation of (S)TEM specimen--a method for obtaining ultrathin lamellae.
Lechner L; Biskupek J; Kaiser U
Microsc Microanal; 2012 Apr; 18(2):379-84. PubMed ID: 22436335
[TBL] [Abstract][Full Text] [Related]
36. Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling.
Sasaki H; Matsuda T; Kato T; Muroga T; Iijima Y; Saitoh T; Iwase F; Yamada Y; Izumi T; Shiohara Y; Hirayama T
J Electron Microsc (Tokyo); 2004; 53(5):497-500. PubMed ID: 15582954
[TBL] [Abstract][Full Text] [Related]
37. 2D-mapping of dopant distribution in deep sub micron CMOS devices by electron holography using adapted FIB-preparation.
Lenk A; Lichte H; Muehle U
J Electron Microsc (Tokyo); 2005 Aug; 54(4):351-9. PubMed ID: 16123059
[TBL] [Abstract][Full Text] [Related]
38. Artifacts introduced by ion milling in Al-Li-Cu alloys.
Singh AK; Imam MA; Sadananda K
J Electron Microsc Tech; 1988 Apr; 8(4):355-61. PubMed ID: 3199219
[TBL] [Abstract][Full Text] [Related]
39. Optimized FIB silicon samples suitable for lattice parameters measurements by convergent beam electron diffraction.
Alexandre L; Rousseau K; Alfonso C; Saikaly W; Fares L; Grosjean C; Charaï A
Micron; 2008; 39(3):294-301. PubMed ID: 17346978
[TBL] [Abstract][Full Text] [Related]
40. Prismatic dentine in the Australian lungfish, Neoceratodus forsteri (Osteichthyes: Dipnoi).
Kemp A; Barry JC
Tissue Cell; 2006 Apr; 38(2):127-40. PubMed ID: 16473380
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]