155 related articles for article (PubMed ID: 19161167)

  • 1. Effect of inflow of fresh blood on vascular-space-occupancy (VASO) contrast.
    Donahue MJ; Hua J; Pekar JJ; van Zijl PC
    Magn Reson Med; 2009 Feb; 61(2):473-80. PubMed ID: 19161167
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Theoretical and experimental investigation of the VASO contrast mechanism.
    Donahue MJ; Lu H; Jones CK; Edden RA; Pekar JJ; van Zijl PC
    Magn Reson Med; 2006 Dec; 56(6):1261-73. PubMed ID: 17075857
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetization transfer enhanced vascular-space-occupancy (MT-VASO) functional MRI.
    Hua J; Donahue MJ; Zhao JM; Grgac K; Huang AJ; Zhou J; van Zijl PC
    Magn Reson Med; 2009 Apr; 61(4):944-51. PubMed ID: 19215043
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Inflow-based vascular-space-occupancy (iVASO) MRI.
    Hua J; Qin Q; Donahue MJ; Zhou J; Pekar JJ; van Zijl PC
    Magn Reson Med; 2011 Jul; 66(1):40-56. PubMed ID: 21695719
    [TBL] [Abstract][Full Text] [Related]  

  • 5. On the measurement of absolute cerebral blood volume (CBV) using vascular-space-occupancy (VASO) MRI.
    Uh J; Lewis-Amezcua K; Varghese R; Lu H
    Magn Reson Med; 2009 Mar; 61(3):659-67. PubMed ID: 19097238
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spatial dependence of CBV-fMRI: a comparison between VASO and contrast agent based methods.
    Jin T; Kim SG
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():25-8. PubMed ID: 17946773
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Vascular space occupancy weighted imaging with control of residual blood signal and higher contrast-to-noise ratio.
    Wu WC; Buxton RB; Wong EC
    IEEE Trans Med Imaging; 2007 Oct; 26(10):1319-27. PubMed ID: 17948723
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improved cortical-layer specificity of vascular space occupancy fMRI with slab inversion relative to spin-echo BOLD at 9.4 T.
    Jin T; Kim SG
    Neuroimage; 2008 Mar; 40(1):59-67. PubMed ID: 18249010
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A review of the development of Vascular-Space-Occupancy (VASO) fMRI.
    Lu H; van Zijl PC
    Neuroimage; 2012 Aug; 62(2):736-42. PubMed ID: 22245650
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detecting resting-state brain activity by spontaneous cerebral blood volume fluctuations using whole brain vascular space occupancy imaging.
    Miao X; Gu H; Yan L; Lu H; Wang DJ; Zhou XJ; Zhuo Y; Yang Y
    Neuroimage; 2014 Jan; 84():575-84. PubMed ID: 24055705
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implementation of vascular-space-occupancy MRI at 7T.
    Hua J; Jones CK; Qin Q; van Zijl PC
    Magn Reson Med; 2013 Apr; 69(4):1003-13. PubMed ID: 22585570
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noninvasive functional imaging of cerebral blood volume with vascular-space-occupancy (VASO) MRI.
    Lu H; Hua J; van Zijl PC
    NMR Biomed; 2013 Aug; 26(8):932-48. PubMed ID: 23355392
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.
    Cheng Y; van Zijl PCM; Pekar JJ; Hua J
    Neuroimage; 2014 Dec; 103():533-541. PubMed ID: 25152092
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Application of whole-brain CBV-weighted fMRI to a cognitive stimulation paradigm: robust activation detection in a stroop task experiment using 3D GRASE VASO.
    Poser BA; Norris DG
    Hum Brain Mapp; 2011 Jun; 32(6):974-81. PubMed ID: 20578174
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimating cerebral blood volume with expanded vascular space occupancy slice coverage.
    Glielmi CB; Schuchard RA; Hu XP
    Magn Reson Med; 2009 May; 61(5):1193-200. PubMed ID: 19253363
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparing hand movement rate dependence of cerebral blood volume and BOLD responses at 7T.
    Oliveira ÍAF; van der Zwaag W; Raimondo L; Dumoulin SO; Siero JCW
    Neuroimage; 2021 Feb; 226():117623. PubMed ID: 33301935
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Integrated VASO and perfusion contrast: A new tool for laminar functional MRI.
    Chai Y; Li L; Huber L; Poser BA; Bandettini PA
    Neuroimage; 2020 Feb; 207():116358. PubMed ID: 31740341
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Functional cerebral blood volume mapping with simultaneous multi-slice acquisition.
    Huber L; Ivanov D; Guidi M; Turner R; Uludağ K; Möller HE; Poser BA
    Neuroimage; 2016 Jan; 125():1159-1168. PubMed ID: 26522423
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multiple acquisitions with global inversion cycling (MAGIC): a multislice technique for vascular-space-occupancy dependent fMRI.
    Lu H; van Zijl PC; Hendrikse J; Golay X
    Magn Reson Med; 2004 Jan; 51(1):9-15. PubMed ID: 14705039
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Slab-selective, BOLD-corrected VASO at 7 Tesla provides measures of cerebral blood volume reactivity with high signal-to-noise ratio.
    Huber L; Ivanov D; Krieger SN; Streicher MN; Mildner T; Poser BA; Möller HE; Turner R
    Magn Reson Med; 2014 Jul; 72(1):137-48. PubMed ID: 23963641
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]