These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 19162705)
21. Preliminary assessment of abdominal organ perfusion utilizing a fiber optic photoplethysmographic sensor. Hickey M; Samuels N; Randive N; Langford R; Kyriacou PA Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1020-3. PubMed ID: 21096995 [TBL] [Abstract][Full Text] [Related]
22. Photoplethysmography behind the Ear Outperforms Electrocardiogram for Cardiovascular Monitoring in Dynamic Environments. Bradke BS; Miller TA; Everman B Sensors (Basel); 2021 Jul; 21(13):. PubMed ID: 34283086 [TBL] [Abstract][Full Text] [Related]
23. Motion artifact reduction in photoplethysmography using independent component analysis. Kim BS; Yoo SK IEEE Trans Biomed Eng; 2006 Mar; 53(3):566-8. PubMed ID: 16532785 [TBL] [Abstract][Full Text] [Related]
24. Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion. Shafique M; Phillips JP; Kyriacou PA Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1024-7. PubMed ID: 21096996 [TBL] [Abstract][Full Text] [Related]
25. Motion Artifact Removal of Photoplethysmogram (PPG) Signal. Majeed IA; Jos S; Arora R; Choi K; Bae S Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():5576-5580. PubMed ID: 31947119 [TBL] [Abstract][Full Text] [Related]
26. Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths. Lee J; Kim M; Park HK; Kim IY Sensors (Basel); 2020 Mar; 20(5):. PubMed ID: 32182772 [TBL] [Abstract][Full Text] [Related]
27. A Wearable Pulse Oximeter With Wireless Communication and Motion Artifact Tailoring for Continuous Use. Chacon PJ; Limeng Pu ; da Costa TH; Young-Ho Shin ; Ghomian T; Shamkhalichenar H; Hsiao-Chun Wu ; Irving BA; Jin-Woo Choi IEEE Trans Biomed Eng; 2019 Jun; 66(6):1505-1513. PubMed ID: 30307850 [TBL] [Abstract][Full Text] [Related]
28. BioTranslator: Inferring R-Peaks from Ambulatory Wrist-Worn PPG Signal. Everson L; Biswas D; Verhoef BE; Kim CH; Van Hoof C; Konijnenburg M; Van Helleputte N Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():4241-4245. PubMed ID: 31946805 [TBL] [Abstract][Full Text] [Related]
29. A comparative evaluation of adaptive noise cancellation algorithms for minimizing motion artifacts in a forehead-mounted wearable pulse oximeter. Comtois G; Mendelson Y; Ramuka P Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1528-31. PubMed ID: 18002258 [TBL] [Abstract][Full Text] [Related]
30. A Textile Sleeve for Monitoring Oxygen Saturation Using Multichannel Optical Fibre Photoplethysmography. Ballaji HK; Correia R; Korposh S; Hayes-Gill BR; Hernandez FU; Salisbury B; Morgan SP Sensors (Basel); 2020 Nov; 20(22):. PubMed ID: 33212998 [TBL] [Abstract][Full Text] [Related]
31. Limitations of oximetry to measure heart rate variability measures. Lu G; Yang F Cardiovasc Eng; 2009 Sep; 9(3):119-25. PubMed ID: 19728090 [TBL] [Abstract][Full Text] [Related]
32. Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: results of a human hypoxia study. Venema B; Blanik N; Blazek V; Gehring H; Opp A; Leonhardt S IEEE Trans Biomed Eng; 2012 Jul; 59(7):2003-10. PubMed ID: 22547451 [TBL] [Abstract][Full Text] [Related]
33. Artifact reduction based on Empirical Mode Decomposition (EMD) in photoplethysmography for pulse rate detection. Wang Q; Yang P; Zhang Y Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():959-62. PubMed ID: 21096980 [TBL] [Abstract][Full Text] [Related]
34. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph. Warren KM; Harvey JR; Chon KH; Mendelson Y Sensors (Basel); 2016 Mar; 16(3):. PubMed ID: 26959034 [TBL] [Abstract][Full Text] [Related]
35. Development of an implantable pulse oximeter. Reichelt S; Fiala J; Werber A; Förster K; Heilmann C; Klemm R; Zappe H IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):581-8. PubMed ID: 18269993 [TBL] [Abstract][Full Text] [Related]
36. Robustness, specificity, and reliability of an in-ear pulse oximetric sensor in surgical patients. Venema B; Gehring H; Michelsen I; Blanik N; Blazek V; Leonhardt S IEEE J Biomed Health Inform; 2014 Jul; 18(4):1178-85. PubMed ID: 25014931 [TBL] [Abstract][Full Text] [Related]
37. Development of an optoelectronic sensor for the investigation of photoplethysmographic signals from the anterior fontanel of the newborn. May JM; Kyriacou PA; Petros AJ Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():18-21. PubMed ID: 22254240 [TBL] [Abstract][Full Text] [Related]
38. Improving pulse oximetry accuracy by removing motion artifacts from photoplethysmograms using relative sensor motion: a preliminary study. Wijshoff RWCGR; Mischi M; Woerlee PH; Aarts RM Adv Exp Med Biol; 2013; 789():411-417. PubMed ID: 23852523 [TBL] [Abstract][Full Text] [Related]
39. Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection-reduction approach. Part I: Motion and noise artifact detection. Chong JW; Dao DK; Salehizadeh SM; McManus DD; Darling CE; Chon KH; Mendelson Y Ann Biomed Eng; 2014 Nov; 42(11):2238-50. PubMed ID: 25092422 [TBL] [Abstract][Full Text] [Related]
40. A Photoplethysmographic Signal Isolated From an Additive Motion Artifact by Frequency Translation. Sinchai S; Kainan P; Wardkein P; Koseeyaporn J IEEE Trans Biomed Circuits Syst; 2018 Aug; 12(4):904-917. PubMed ID: 29994775 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]