These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 19163101)

  • 1. Conducting polymer based active catheter for minimally invasive interventions inside arteries.
    Shoa T; Madden JD; Fekri N; Munce NR; Yang VX
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2063-6. PubMed ID: 19163101
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Active catheter driven by a thermo-hydraulic actuation.
    Horovitz Y; Kosa G
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():7772-5. PubMed ID: 26738094
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface modification of neural recording electrodes with conducting polymer/biomolecule blends.
    Cui X; Lee VA; Raphael Y; Wiler JA; Hetke JF; Anderson DJ; Martin DC
    J Biomed Mater Res; 2001 Aug; 56(2):261-72. PubMed ID: 11340598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Physical surface and electromechanical properties of doped polypyrrole biomaterials.
    Gelmi A; Higgins MJ; Wallace GG
    Biomaterials; 2010 Mar; 31(8):1974-83. PubMed ID: 20056273
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Study on active catheter for minimally invasive surgery based on large deflection theory].
    Wang S; Liu H; Fu Y; Li X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):393-7. PubMed ID: 18610629
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microbore catheters: keys to successful design and manufacture, Part I.
    Kramer HW
    Med Device Technol; 2001 Oct; 12(8):14-6. PubMed ID: 12938543
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Steerable catheters for minimally invasive surgery: a review and future directions.
    Hu X; Chen A; Luo Y; Zhang C; Zhang E
    Comput Assist Surg (Abingdon); 2018 Dec; 23(1):21-41. PubMed ID: 30497292
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design of a multifunctional compliant instrument for minimally invasive surgery.
    Frecker MI; Powell KM; Haluck R
    J Biomech Eng; 2005 Nov; 127(6):990-3. PubMed ID: 16438237
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Research on the axis shape of an active catheter.
    Fu Y; Li X; Wang S; Liu H; Liang Z
    Int J Med Robot; 2008 Mar; 4(1):69-76. PubMed ID: 18240336
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a compliant device for minimally invasive surgery.
    Meier P; Oberthür S; Lang M
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():331-4. PubMed ID: 17945579
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Carboxy-endcapped conductive polypyrrole: biomimetic conducting polymer for cell scaffolds and electrodes.
    Lee JW; Serna F; Schmidt CE
    Langmuir; 2006 Nov; 22(24):9816-9. PubMed ID: 17106966
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Study on an actuation system for matrix control of the active catheter in a minimally-invasive intervention surgery].
    Fu YL; Ma HH; Li XL
    Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Nov; 30(6):416-8, 430. PubMed ID: 17300007
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Concept of an artificial muscle design on polypyrrole nanofiber scaffolds.
    Harjo M; Järvekülg M; Tamm T; Otero TF; Kiefer R
    PLoS One; 2020; 15(5):e0232851. PubMed ID: 32392238
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Conducting polymers grown in hydrogel scaffolds coated on neural prosthetic devices.
    Kim DH; Abidian M; Martin DC
    J Biomed Mater Res A; 2004 Dec; 71(4):577-85. PubMed ID: 15514937
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A catheter side wall tactile sensor: design, modeling and experiments.
    Wang H; Liu PX; Guo S; Ye X
    Minim Invasive Ther Allied Technol; 2010; 19(1):52-60. PubMed ID: 20095899
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Investigation of polypyrrole/glucose oxidase electrodes by ellipsometric, microgravimetric and electrochemical measurements.
    Rishpon J; Gottesfeld S
    Biosens Bioelectron; 1991; 6(2):143-9. PubMed ID: 2059400
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impedance spectra of polypyrrole coated platinum electrodes.
    Onnela N; Savolainen V; Hiltunen M; Kellomäki M; Hyttinen J
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():539-42. PubMed ID: 24109743
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrochemically controlled release of dexamethasone from conducting polymer polypyrrole coated electrode.
    Wadhwa R; Lagenaur CF; Cui XT
    J Control Release; 2006 Feb; 110(3):531-41. PubMed ID: 16360955
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polypyrrole as Electrically Conductive Biomaterials: Synthesis, Biofunctionalization, Potential Applications and Challenges.
    Mao J; Zhang Z
    Adv Exp Med Biol; 2018; 1078():347-370. PubMed ID: 30357632
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fabrication of conducting polymer micro/nanostructures coated with Au nanoparticles for electrochemical sensors.
    An T; Choi W; Lee E; Cho SJ; Lim G
    J Nanosci Nanotechnol; 2012 Jun; 12(6):4975-8. PubMed ID: 22905561
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.