134 related articles for article (PubMed ID: 19163977)
1. Denoising of diaphragmatic electromyogram signals for respiratory control and diagnostic purposes.
Alty SR; Man WD; Moxham J; Lee KC
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5560-3. PubMed ID: 19163977
[TBL] [Abstract][Full Text] [Related]
2. A wavelet-based adaptive filter for removing ECG interference in EMGdi signals.
Zhan C; Yeung LF; Yang Z
J Electromyogr Kinesiol; 2010 Jun; 20(3):542-9. PubMed ID: 19692270
[TBL] [Abstract][Full Text] [Related]
3. Contribution to structural intensity tool: application to the cancellation of ECG interference in diaphragmatic EMG.
Aithocine E; Guméry PY; Meignen S; Heyer L; Lavault Y; Gottfried SB
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5-8. PubMed ID: 17945968
[TBL] [Abstract][Full Text] [Related]
4. Real time ECG artifact removal for myoelectric prosthesis control.
Zhou P; Lock B; Kuiken TA
Physiol Meas; 2007 Apr; 28(4):397-413. PubMed ID: 17395995
[TBL] [Abstract][Full Text] [Related]
5. Reducing electrocardiographic artifacts from electromyogram signals with independent component analysis.
Costa Junior JD; Ferreira DD; Nadal J; Miranda de Sa AL
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():4598-601. PubMed ID: 21096226
[TBL] [Abstract][Full Text] [Related]
6. A simple method to remove ECG artifacts from trunk muscle EMG signals.
Hof AL
J Electromyogr Kinesiol; 2009 Dec; 19(6):e554-5. PubMed ID: 19121951
[No Abstract] [Full Text] [Related]
7. Improvement in Neural Respiratory Drive Estimation From Diaphragm Electromyographic Signals Using Fixed Sample Entropy.
Estrada L; Torres A; Sarlabous L; Jané R
IEEE J Biomed Health Inform; 2016 Mar; 20(2):476-85. PubMed ID: 25667362
[TBL] [Abstract][Full Text] [Related]
8. Development of three methods for extracting respiration from the surface ECG: a review.
Helfenbein E; Firoozabadi R; Chien S; Carlson E; Babaeizadeh S
J Electrocardiol; 2014; 47(6):819-25. PubMed ID: 25194875
[TBL] [Abstract][Full Text] [Related]
9. ECG denoising based on the empirical mode decomposition.
Weng B; Blanco-Velasco M; Barner KE
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1-4. PubMed ID: 17945967
[TBL] [Abstract][Full Text] [Related]
10. [Application of independent component analysis to ECG cancellation in surface electromyography measurement].
Cao Y; Chen C; Hu Y
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Aug; 22(4):686-9. PubMed ID: 16156250
[TBL] [Abstract][Full Text] [Related]
11. Nonstationary harmonic modeling for ECG removal in surface EMG signals.
Zivanovic M; González-Izal M
IEEE Trans Biomed Eng; 2012 Jun; 59(6):1633-40. PubMed ID: 22453600
[TBL] [Abstract][Full Text] [Related]
12. EMG-based detection of inspiration in the rat diaphragm muscle.
Dow DE; Mantilla CB; Zhan WZ; Sieck GC
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1204-7. PubMed ID: 17946030
[TBL] [Abstract][Full Text] [Related]
13. Application of Empirical Mode Decomposition Combined With Notch Filtering for Interpretation of Surface Electromyograms During Functional Electrical Stimulation.
Pilkar R; Yarossi M; Ramanujam A; Rajagopalan V; Bayram MB; Mitchell M; Canton S; Forrest G
IEEE Trans Neural Syst Rehabil Eng; 2017 Aug; 25(8):1268-1277. PubMed ID: 27834646
[TBL] [Abstract][Full Text] [Related]
14. The interpretation of abdominal wall muscle recruitment strategies change when the electrocardiogram (ECG) is removed from the electromyogram (EMG).
Butler HL; Newell R; Hubley-Kozey CL; Kozey JW
J Electromyogr Kinesiol; 2009 Apr; 19(2):e102-13. PubMed ID: 18055221
[TBL] [Abstract][Full Text] [Related]
15. Correlation and compatibility between surface respiratory electromyography and transesophageal diaphragmatic electromyography measurements during treadmill exercise in stable patients with COPD.
Wu W; Guan L; Li X; Lin L; Guo B; Yang Y; Liang Z; Wang F; Zhou L; Chen R
Int J Chron Obstruct Pulmon Dis; 2017; 12():3273-3280. PubMed ID: 29158671
[TBL] [Abstract][Full Text] [Related]
16. ECG denoising using modulus maxima of wavelet transform.
Ayat M; Shamsollahi MB; Mozaffari B; Kharabian S
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():416-9. PubMed ID: 19963460
[TBL] [Abstract][Full Text] [Related]
17. Morphological ECG subtraction method for removing ECG artifacts from diaphragm EMG.
Guo L; Li ZW; Zhang H; Li SM; Zhang JH
Technol Health Care; 2023; 31(S1):333-345. PubMed ID: 37066934
[TBL] [Abstract][Full Text] [Related]
18. Description and validation of an ECG removal procedure for EMGdi power spectrum analysis.
Levine S; Gillen J; Weiser P; Gillen M; Kwatny E
J Appl Physiol (1985); 1986 Mar; 60(3):1073-81. PubMed ID: 3957823
[TBL] [Abstract][Full Text] [Related]
19. Removing ECG contamination from EMG recordings: a comparison of ICA-based and other filtering procedures.
Willigenburg NW; Daffertshofer A; Kingma I; van Dieën JH
J Electromyogr Kinesiol; 2012 Jun; 22(3):485-93. PubMed ID: 22296869
[TBL] [Abstract][Full Text] [Related]
20. ECG Artifact Removal from Surface EMG Signal Using an Automated Method Based on Wavelet-ICA.
Abbaspour S; Lindén M; Gholamhosseini H
Stud Health Technol Inform; 2015; 211():91-7. PubMed ID: 25980853
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]