187 related articles for article (PubMed ID: 19164411)
1. Immediate loading of orthodontic mini-implants: a histomorphometric evaluation of tissue reaction.
Luzi C; Verna C; Melsen B
Eur J Orthod; 2009 Feb; 31(1):21-9. PubMed ID: 19164411
[TBL] [Abstract][Full Text] [Related]
2. Orthodontic loading of titanium miniplates in dogs: microradiographic and histological evaluation.
Cornelis MA; Vandergugten S; Mahy P; De Clerck HJ; Lengelé B; D'Hoore W; Nyssen-Behets C
Clin Oral Implants Res; 2008 Oct; 19(10):1054-62. PubMed ID: 18828822
[TBL] [Abstract][Full Text] [Related]
3. The effect of force, timing, and location on bone-to-implant contact of miniscrew implants.
Woods PW; Buschang PH; Owens SE; Rossouw PE; Opperman LA
Eur J Orthod; 2009 Jun; 31(3):232-40. PubMed ID: 19073958
[TBL] [Abstract][Full Text] [Related]
4. Orthodontic load on short maxillary implants with reduced sink depth: an experimental study.
Wehrbein H; Göllner P; Diedrich P
Clin Oral Implants Res; 2008 Oct; 19(10):1063-8. PubMed ID: 18828823
[TBL] [Abstract][Full Text] [Related]
5. Bone-to-implant contact of orthodontic implants in humans--a histomorphometric investigation.
Jung BA; Yildizhan F; Wehrbein H
Eur J Orthod; 2008 Dec; 30(6):552-7. PubMed ID: 19054812
[TBL] [Abstract][Full Text] [Related]
6. A comparison of stability between delayed versus immediately loaded orthodontic palatal implants.
Jackson A; Lemke R; Hatch J; Salome N; Gakunga P; Cochran D
J Esthet Restor Dent; 2008; 20(3):174-84. PubMed ID: 18533979
[TBL] [Abstract][Full Text] [Related]
7. Factors associated with the stability of mini-implants for orthodontic anchorage: a study of 414 samples in Taiwan.
Wu TY; Kuang SH; Wu CH
J Oral Maxillofac Surg; 2009 Aug; 67(8):1595-9. PubMed ID: 19615569
[TBL] [Abstract][Full Text] [Related]
8. Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage.
Freire JN; Silva NR; Gil JN; Magini RS; Coelho PG
Am J Orthod Dentofacial Orthop; 2007 Jun; 131(6):704.e1-9. PubMed ID: 17561041
[TBL] [Abstract][Full Text] [Related]
9. Sequential bone healing of immediately loaded mini-implants: histomorphometric and fluorescence analysis.
Serra G; Morais LS; Elias CN; Meyers MA; Andrade L; Müller CA; Müller M
Am J Orthod Dentofacial Orthop; 2010 Jan; 137(1):80-90. PubMed ID: 20122435
[TBL] [Abstract][Full Text] [Related]
10. Clinical and histologic analysis of the stability of microimplants with immediate orthodontic loading in dogs.
Chen Y; Kang ST; Bae SM; Kyung HM
Am J Orthod Dentofacial Orthop; 2009 Aug; 136(2):260-7. PubMed ID: 19651357
[TBL] [Abstract][Full Text] [Related]
11. Potential of self-drilling orthodontic microimplants under immediate loading.
Chen Y; Lee JW; Cho WH; Kyung HM
Am J Orthod Dentofacial Orthop; 2010 Apr; 137(4):496-502. PubMed ID: 20362909
[TBL] [Abstract][Full Text] [Related]
12. The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study.
Cho YM; Cha JY; Hwang CJ
Eur J Orthod; 2010 Dec; 32(6):614-9. PubMed ID: 20466772
[TBL] [Abstract][Full Text] [Related]
13. Osseointegration of miniscrews: a histomorphometric evaluation.
Vande Vannet B; Sabzevar MM; Wehrbein H; Asscherickx K
Eur J Orthod; 2007 Oct; 29(5):437-42. PubMed ID: 17974533
[TBL] [Abstract][Full Text] [Related]
14. Sequential bone healing of immediately loaded mini-implants.
Serra G; Morais LS; Elias CN; Meyers MA; Andrade L; Muller C; Muller M
Am J Orthod Dentofacial Orthop; 2008 Jul; 134(1):44-52. PubMed ID: 18617102
[TBL] [Abstract][Full Text] [Related]
15. Peri-implant bone organization under immediate loading conditions: collagen fiber orientation and mineral density analyses in the minipig model.
Traini T; Neugebauer J; Thams U; Zöller JE; Caputi S; Piattelli A
Clin Implant Dent Relat Res; 2009 Mar; 11(1):41-51. PubMed ID: 18657155
[TBL] [Abstract][Full Text] [Related]
16. Orthodontic mini-implant stability in different healing times before loading: a microscopic computerized tomographic and biomechanical analysis.
Zhao L; Xu Z; Yang Z; Wei X; Tang T; Zhao Z
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Aug; 108(2):196-202. PubMed ID: 19615659
[TBL] [Abstract][Full Text] [Related]
17. Threaded versus porous-surfaced implants as anchorage units for orthodontic treatment: three-dimensional finite element analysis of peri-implant bone tissue stresses.
Pilliar RM; Sagals G; Meguid SA; Oyonarte R; Deporter DA
Int J Oral Maxillofac Implants; 2006; 21(6):879-89. PubMed ID: 17190297
[TBL] [Abstract][Full Text] [Related]
18. The effect of miniscrew taper morphology on insertion and removal torque in dogs.
Cha JY; Takano-Yamamoto T; Hwang CJ
Int J Oral Maxillofac Implants; 2010; 25(4):777-83. PubMed ID: 20657874
[TBL] [Abstract][Full Text] [Related]
19. Primary loading of palatal implants for orthodontic anchorage--a pilot animal study.
Borbély P; Dunay MP; Jung BA; Wehrbein H; Wagner W; Kunkel M
J Craniomaxillofac Surg; 2008 Jan; 36(1):21-7. PubMed ID: 17988886
[TBL] [Abstract][Full Text] [Related]
20. The impact of healing time before loading on orthodontic mini-implant stability: a histomorphometric study in minipigs.
Oltramari-Navarro PV; Navarro RL; Henriques JF; Cestari TM; Francischone CE; Taga R; McNamara JA
Arch Oral Biol; 2013 Jul; 58(7):806-12. PubMed ID: 23337099
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]