BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 19165881)

  • 1. Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.
    Deng W; Yang C; Alagappan V; Wald LL; Boada FE; Stenger VA
    Magn Reson Med; 2009 Feb; 61(2):255-9. PubMed ID: 19165881
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.
    Yang C; Deng W; Stenger VA
    Magn Reson Med; 2011 Feb; 65(2):370-6. PubMed ID: 21264930
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust time-shifted spoke pulse design in the presence of large B0 variations with simultaneous reduction of through-plane dephasing, B1+ effects, and the specific absorption rate using parallel transmission.
    Guérin B; Stockmann JP; Baboli M; Torrado-Carvajal A; Stenger AV; Wald LL
    Magn Reson Med; 2016 Aug; 76(2):540-54. PubMed ID: 26444717
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Slice-selective RF pulses for in vivo B1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16-element coil.
    Setsompop K; Alagappan V; Gagoski B; Witzel T; Polimeni J; Potthast A; Hebrank F; Fontius U; Schmitt F; Wald LL; Adalsteinsson E
    Magn Reson Med; 2008 Dec; 60(6):1422-32. PubMed ID: 19025908
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Advanced three-dimensional tailored RF pulse for signal recovery in T2*-weighted functional magnetic resonance imaging.
    Yip CY; Fessler JA; Noll DC
    Magn Reson Med; 2006 Nov; 56(5):1050-9. PubMed ID: 17041911
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spectral decomposition of susceptibility artifacts for spectral-spatial radiofrequency pulse design.
    Yang C; Poser BA; Deng W; Stenger VA
    Magn Reson Med; 2012 Dec; 68(6):1905-10. PubMed ID: 22334396
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous multislice imaging with slice-multiplexed RF pulses.
    Lee KJ; Wild JM; Griffiths PD; Paley MN
    Magn Reson Med; 2005 Oct; 54(4):755-60. PubMed ID: 16155891
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automated slice-specific simultaneous z-shim method for reducing B1 inhomogeneity and susceptibility-induced signal loss with parallel transmission at 3T.
    Schneider R; Boada F; Haueisen J; Pfeuffer J
    Magn Reson Med; 2015 Oct; 74(4):934-44. PubMed ID: 25291423
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time feedback optimization of z-shim gradient for automatic compensation of susceptibility-induced signal loss in EPI.
    Tang YW; Huang TY
    Neuroimage; 2011 Apr; 55(4):1587-92. PubMed ID: 21256230
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Four-dimensional spectral-spatial RF pulses for simultaneous correction of B1+ inhomogeneity and susceptibility artifacts in T2*-weighted MRI.
    Yang C; Deng W; Alagappan V; Wald LL; Stenger VA
    Magn Reson Med; 2010 Jul; 64(1):1-8. PubMed ID: 20577982
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Parallel excitation in the human brain at 9.4 T counteracting k-space errors with RF pulse design.
    Wu X; Vaughan JT; Uğurbil K; Van de Moortele PF
    Magn Reson Med; 2010 Feb; 63(2):524-9. PubMed ID: 20017161
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single-shot 3D GRASE with cylindrical k-space trajectories.
    Ramanna S; Feinberg DA
    Magn Reson Med; 2008 Oct; 60(4):976-80. PubMed ID: 18816819
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction.
    den Harder JC; van Yperen GH; Blume UA; Bos C
    Magn Reson Med; 2015 Jan; 73(1):318-24. PubMed ID: 24488701
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improved susceptibility weighted imaging method using multi-echo acquisition.
    Oh SS; Oh SH; Nam Y; Han D; Stafford RB; Hwang J; Kim DH; Park H; Lee J
    Magn Reson Med; 2014 Aug; 72(2):452-8. PubMed ID: 24105838
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous multislice excitation by parallel transmission.
    Poser BA; Anderson RJ; Guérin B; Setsompop K; Deng W; Mareyam A; Serano P; Wald LL; Stenger VA
    Magn Reson Med; 2014 Apr; 71(4):1416-27. PubMed ID: 23716365
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Direct signal control of the steady-state response of 3D-FSE sequences.
    Malik SJ; Beqiri A; Padormo F; Hajnal JV
    Magn Reson Med; 2015 Mar; 73(3):951-63. PubMed ID: 24639096
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.
    Saekho S; Boada FE; Noll DC; Stenger VA
    Magn Reson Med; 2005 Feb; 53(2):479-84. PubMed ID: 15678525
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mitigate B1+ inhomogeneity using spatially selective radiofrequency excitation with generalized spatial encoding magnetic fields.
    Hsu YC; Chern IL; Zhao W; Gagoski B; Witzel T; Lin FH
    Magn Reson Med; 2014 Apr; 71(4):1458-69. PubMed ID: 23794127
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Strategies for improved 3D small-tip fast recovery imaging.
    Sun H; Fessler JA; Noll DC; Nielsen JF
    Magn Reson Med; 2014 Aug; 72(2):389-98. PubMed ID: 24127132
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correcting slice selectivity in hard pulse sequences.
    Grodzki DM; Jakob PM; Heismann B
    J Magn Reson; 2012 Jan; 214(1):61-7. PubMed ID: 22047992
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.