These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Molecular evidence for the ubiquitous presence of Legionella species in Dutch tap water installations. Diederen BM; de Jong CM; Aarts I; Peeters MF; van der Zee A J Water Health; 2007 Sep; 5(3):375-83. PubMed ID: 17878552 [TBL] [Abstract][Full Text] [Related]
23. Quantitative detection of Legionella pneumophila in water samples by immunomagnetic purification and real-time PCR amplification of the dotA gene. Yáñez MA; Carrasco-Serrano C; Barberá VM; Catalán V Appl Environ Microbiol; 2005 Jul; 71(7):3433-41. PubMed ID: 16000746 [TBL] [Abstract][Full Text] [Related]
25. Antibiotic susceptibilities of Legionella pneumophila strain Paris in THP-1 cells as determined by real-time PCR assay. Roch N; Maurin M J Antimicrob Chemother; 2005 Jun; 55(6):866-71. PubMed ID: 15883178 [TBL] [Abstract][Full Text] [Related]
26. LAMP-based method for a rapid identification of Legionella spp. and Legionella pneumophila. Lu X; Mo ZY; Zhao HB; Yan H; Shi L Appl Microbiol Biotechnol; 2011 Oct; 92(1):179-87. PubMed ID: 21847513 [TBL] [Abstract][Full Text] [Related]
27. Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems. Yaradou DF; Hallier-Soulier S; Moreau S; Poty F; Hillion Y; Reyrolle M; André J; Festoc G; Delabre K; Vandenesch F; Etienne J; Jarraud S Appl Environ Microbiol; 2007 Mar; 73(5):1452-6. PubMed ID: 17194840 [TBL] [Abstract][Full Text] [Related]
28. Inhibition of Legionella pneumophila PCR in respiratory samples: a quantitative approach. Kern M; Böhm S; Deml L; Wolf H; Reischl U; Niller HH J Microbiol Methods; 2009 Nov; 79(2):189-93. PubMed ID: 19747952 [TBL] [Abstract][Full Text] [Related]
29. Detection of airborne Legionella while showering using liquid impingement and fluorescent in situ hybridization (FISH). Deloge-Abarkan M; Ha TL; Robine E; Zmirou-Navier D; Mathieu L J Environ Monit; 2007 Jan; 9(1):91-7. PubMed ID: 17213948 [TBL] [Abstract][Full Text] [Related]
30. Targeting single-nucleotide polymorphisms in the 16S rRNA gene to detect and differentiate Legionella pneumophila and non-Legionella pneumophila species. Zhan XY; Hu CH; Zhu QY Arch Microbiol; 2016 Aug; 198(6):591-4. PubMed ID: 27112927 [TBL] [Abstract][Full Text] [Related]
31. Quantitative real-time Legionella PCR for environmental water samples: data interpretation. Joly P; Falconnet PA; André J; Weill N; Reyrolle M; Vandenesch F; Maurin M; Etienne J; Jarraud S Appl Environ Microbiol; 2006 Apr; 72(4):2801-8. PubMed ID: 16597985 [TBL] [Abstract][Full Text] [Related]
32. Sensitive detection of lip genes by electrochemical DNA sensor and its application in polymerase chain reaction amplicons from Phanerochaete chrysosporium. Tang L; Zeng G; Shen G; Li Y; Liu C; Li Z; Luo J; Fan C; Yang C Biosens Bioelectron; 2009 Jan; 24(5):1474-9. PubMed ID: 19010661 [TBL] [Abstract][Full Text] [Related]
33. Towards Q-PCR of pathogenic bacteria with improved electrochemical double-tagged genosensing detection. Lermo A; Zacco E; Barak J; Delwiche M; Campoy S; Barbé J; Alegret S; Pividori MI Biosens Bioelectron; 2008 Jul; 23(12):1805-11. PubMed ID: 18407486 [TBL] [Abstract][Full Text] [Related]
34. Efficacy of the detection of Legionella in hot and cold water samples by culture and PCR. II. Examination of native samples from various sources. Stojek NM; Wójcik-Fatla A; Dutkiewicz J Ann Agric Environ Med; 2012; 19(2):295-8. PubMed ID: 22742805 [TBL] [Abstract][Full Text] [Related]
35. Evaluation of a Legionella urinary antigen enzyme immunoassay for rapid detection of Legionella pneumophila in water samples. Blanco S; Prat C; Sánchez MD; Ferrer D; Pellicer T; Haba L; Latorre I; Vilaplana C; Ausina V; Domínguez J Int J Hyg Environ Health; 2008 Mar; 211(1-2):168-71. PubMed ID: 17392021 [TBL] [Abstract][Full Text] [Related]
36. Qualitative detection of Legionella species in bronchoalveolar lavages and induced sputa by automated DNA extraction and real-time polymerase chain reaction. Raggam RB; Leitner E; Mühlbauer G; Berg J; Stöcher M; Grisold AJ; Marth E; Kessler HH Med Microbiol Immunol; 2002 Oct; 191(2):119-25. PubMed ID: 12410352 [TBL] [Abstract][Full Text] [Related]
37. Detection of Legionella pneumophila in bioaerosols by polymerase chain reaction. Pascual L; Pérez-Luz S; Amo A; Moreno C; Apraiz D; Catalán V Can J Microbiol; 2001 Apr; 47(4):341-7. PubMed ID: 11358174 [TBL] [Abstract][Full Text] [Related]
38. Flow analysis coupled with PQC/DNA biosensor for assay of E. coli based on detecting DNA products from PCR amplification. Sun H; Zhang Y; Fung Y Biosens Bioelectron; 2006 Oct; 22(4):506-12. PubMed ID: 16971109 [TBL] [Abstract][Full Text] [Related]
39. Detection of legionellae in hospital water samples by quantitative real-time LightCycler PCR. Wellinghausen N; Frost C; Marre R Appl Environ Microbiol; 2001 Sep; 67(9):3985-93. PubMed ID: 11525995 [TBL] [Abstract][Full Text] [Related]
40. Preparation of screen-printed electrochemical immunosensors for estradiol, and their application in biological fluids. Pemberton RM; Hart JP Methods Mol Biol; 2009; 504():85-98. PubMed ID: 19159092 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]