BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 19170905)

  • 41. An observational registry on efficacy and safety of the right ventricular outflow tract as a site for ICD leads: results of the EFFORT (EFFicacy Of Right ventricular outflow Tract as site for ICD leads) registry.
    Mascioli G; Gelmini G; Reggiani A; Giudici V; Spotti A; Mocini A; Marconi R; Ruffa F; Zanotto G
    J Interv Card Electrophysiol; 2010 Sep; 28(3):215-20. PubMed ID: 20577792
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Survival analysis in patients with preserved left ventricular function and standard indications for permanent cardiac pacing randomized to right ventricular apical or septal outflow tract pacing.
    Dabrowska-Kugacka A; Lewicka-Nowak E; Tybura S; Wilczek R; Staniewicz J; Zagozdzon P; Faran A; Kozłowski D; Raczak G; Swiatecka G
    Circ J; 2009 Oct; 73(10):1812-9. PubMed ID: 19690393
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The right ventricular septum presents the optimum site for maximal electrical separation during left ventricular pacing.
    Miranda RI; Nault M; Simpson CS; Michael KA; Abdollah H; Baranchuk A; Redfearn DP
    J Cardiovasc Electrophysiol; 2012 Apr; 23(4):370-4. PubMed ID: 22049976
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Effect of right ventricular pacing site on QRS width.
    Nakamura H; Mine T; Kanemori T; Ohyanagi M; Masuyama T
    Asian Cardiovasc Thorac Ann; 2011 Oct; 19(5):339-45. PubMed ID: 22100929
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Serial changes in right ventricular apical pacing lead impedance predict changes in left ventricular ejection fraction and functional class in heart failure patients.
    Stambler BS; Ellenbogen KA; Liu Z; Levine P; Porter TR; Zhang X;
    Pacing Clin Electrophysiol; 2005 Jan; 28 Suppl 1():S50-3. PubMed ID: 15683525
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Atrial lead placement at the lower atrial septum: a potential strategy to reduce unnecessary right ventricular pacing.
    Acosta H; Viafara LM; Izquierdo D; Pothula VR; Bear J; Pothula S; Antonio-Drabeck C; Lee K
    Europace; 2012 Sep; 14(9):1311-6. PubMed ID: 22454410
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing.
    Mair H; Sachweh J; Meuris B; Nollert G; Schmoeckel M; Schuetz A; Reichart B; Daebritz S
    Eur J Cardiothorac Surg; 2005 Feb; 27(2):235-42. PubMed ID: 15691676
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Selective site pacing from the right ventricular mid-septum. Follow-up of lead performance and procedure technique.
    Yusu S; Mera H; Hoshida K; Miyakoshi M; Miwa Y; Tsukada T; Yoshino H; Ikeda T
    Int Heart J; 2012; 53(2):113-6. PubMed ID: 22688315
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Implantation and follow-up of ICD leads implanted in the right ventricular outflow tract.
    Lubinski A; Lewicka-Nowak E; Królak T; Kempa M; Bielawska B; Wilczek R; Swiatecka G
    Pacing Clin Electrophysiol; 2000 Nov; 23(11 Pt 2):1996-8. PubMed ID: 11139976
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Pacing from the right ventricular septum: is there a danger to the coronary arteries?
    Teh AW; Medi C; Rosso R; Lee G; Gurvitch R; Mond HG
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):894-7. PubMed ID: 19572865
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Effect of right ventricular lead location on response to cardiac resynchronization therapy in patients with end-stage heart failure.
    Haghjoo M; Bonakdar HR; Jorat MV; Fazelifar AF; Alizadeh A; Ojaghi-Haghjghi Z; Esmaielzadeh M; Sadr-Ameli MA
    Europace; 2009 Mar; 11(3):356-63. PubMed ID: 19136489
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Comparison of different pacing sites of the right ventricle on left ventricular mechanical synchrony and systolic performance using tissue Doppler imaging].
    Shi HY; Wang F; Meng WD; Zhang F; Sun YP; Sun BG
    Zhonghua Xin Xue Guan Bing Za Zhi; 2005 Nov; 33(11):1002-5. PubMed ID: 16563247
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Report on initiating clinical research for electrical and mechanical synchronism of selective region pacing in the right ventricular].
    Cai L; Huang DJ; Yan CB; Rao L; Liu JX; Liu HX
    Zhonghua Xin Xue Guan Bing Za Zhi; 2007 Feb; 35(2):147-50. PubMed ID: 17445410
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Alternate site pacing in patients at risk for heart failure.
    Manolis AS; Sakellariou D; Andrikopoulos GK
    Angiology; 2008; 59(2 Suppl):97S-102S. PubMed ID: 18632765
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Right ventricular pacemaker lead position is associated with differences in long-term outcomes and complications.
    Witt CM; Lenz CJ; Shih HH; Ebrille E; Rosenbaum AN; van Zyl M; Aung H; Manocha KK; Deshmukh AJ; Hodge DO; Mulpuru SK; Cha YM; Espinosa RE; Asirvatham SJ; Mcleod CJ
    J Cardiovasc Electrophysiol; 2017 Aug; 28(8):924-930. PubMed ID: 28543771
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Advances in cardiac pacing: beyond the transvenous right ventricular apical lead.
    Kapa S; Bruce CJ; Friedman PA; Asirvatham SJ
    Cardiovasc Ther; 2010 Dec; 28(6):369-79. PubMed ID: 20553288
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Long-term stability of endocardial left ventricular pacing leads placed via the coronary sinus.
    Lin G; Anavekar NS; Webster TL; Rea RF; Hayes DL; Brady PA
    Pacing Clin Electrophysiol; 2009 Sep; 32(9):1117-22. PubMed ID: 19719486
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Pacing site in pacemaker dependency: is right ventricular septal lead position the answer?
    Kaye G
    Expert Rev Cardiovasc Ther; 2014 Dec; 12(12):1407-17. PubMed ID: 25418757
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Long-term follow-up impact of dual-chamber pacing on patients with hypertrophic obstructive cardiomyopathy.
    Yue-Cheng H; Zuo-Cheng L; Xi-Ming L; Yuan DZ; Dong-Xia J; Ying-Yi Z; Hui-Ming Y; Hong-Liang C
    Pacing Clin Electrophysiol; 2013 Jan; 36(1):86-93. PubMed ID: 23078085
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Alternative right ventricular pacing sites.
    Łuciuk D; Łuciuk M; Gajek J
    Adv Clin Exp Med; 2015; 24(2):349-59. PubMed ID: 25931370
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.