These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
374 related articles for article (PubMed ID: 19173051)
41. Comparative study of solvent extraction and thermal desorption methods for determining a wide range of volatile organic compounds in ambient air. Ramírez N; Cuadras A; Rovira E; Borrull F; Marcé RM Talanta; 2010 Jul; 82(2):719-27. PubMed ID: 20602960 [TBL] [Abstract][Full Text] [Related]
42. Facile hyphenation of gas chromatography and a microcantilever array sensor for enhanced selectivity. Chapman PJ; Vogt F; Dutta P; Datskos PG; Devault GL; Sepaniak MJ Anal Chem; 2007 Jan; 79(1):364-70. PubMed ID: 17194162 [TBL] [Abstract][Full Text] [Related]
43. A micro GC detector array based on chemiresistors employing various surface functionalized monolayer-protected gold nanoparticles. Jian RS; Huang RX; Lu CJ Talanta; 2012 Jan; 88():160-7. PubMed ID: 22265482 [TBL] [Abstract][Full Text] [Related]
44. [Determination of volatile organic compounds in atmospheric environment]. Chen HW; Li GK; Li H; Zhang ZX; Wang BG; Li T; Luo HK Se Pu; 2001 Nov; 19(6):544-8. PubMed ID: 12545471 [TBL] [Abstract][Full Text] [Related]
45. Development of a sensitive thermal desorption method for the determination of trihalomethanes in humid ambient and alveolar air. Caro J; Gallego M Talanta; 2008 Aug; 76(4):847-53. PubMed ID: 18656668 [TBL] [Abstract][Full Text] [Related]
46. Aerostat-lofted instrument and sampling method for determination of emissions from open area sources. Aurell J; Gullett BK; Pressley C; Tabor DG; Gribble RD Chemosphere; 2011 Oct; 85(5):806-11. PubMed ID: 21840564 [TBL] [Abstract][Full Text] [Related]
47. Design and field application of an automated cartridge sampler for VOC concentration and flux measurements. Kuhn U; Dindorf T; Ammann C; Rottenberger S; Guyon P; Holzinger R; Ausma S; Kenntner T; Helleis F; Kesselmeier J J Environ Monit; 2005 Jun; 7(6):568-76. PubMed ID: 15931416 [TBL] [Abstract][Full Text] [Related]
48. Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer. Shortt BJ; Darrach MR; Holland PM; Chutjian A J Mass Spectrom; 2005 Jan; 40(1):36-42. PubMed ID: 15619267 [TBL] [Abstract][Full Text] [Related]
49. Direct monitoring of toxic compounds in air using a portable mass spectrometer. Mulligan CC; Justes DR; Noll RJ; Sanders NL; Laughlin BC; Cooks RG Analyst; 2006 Apr; 131(4):556-67. PubMed ID: 16568173 [TBL] [Abstract][Full Text] [Related]
50. Process sampling module coupled with purge and trap-GC-FID for in situ auto-monitoring of volatile organic compounds in wastewater. Liu HW; Liu YT; Wu BZ; Nian HC; Chen HJ; Chiu KH; Lo JG Talanta; 2009 Dec; 80(2):903-8. PubMed ID: 19836571 [TBL] [Abstract][Full Text] [Related]
51. Automated measurement and calibration of reactive volatile halogenated organic compounds in the atmosphere. Wevill DJ; Carpenter LJ Analyst; 2004 Jul; 129(7):634-8. PubMed ID: 15213832 [TBL] [Abstract][Full Text] [Related]
52. In-line sampling with gas chromatography-mass spectrometry to monitor ambient volatile organic compounds. Wang JL; Chang CC; Lee KZ J Chromatogr A; 2012 Jul; 1248():161-8. PubMed ID: 22717034 [TBL] [Abstract][Full Text] [Related]
53. Field comparison of passive air samplers with reference monitors for ambient volatile organic compounds and nitrogen dioxide under week-long integrals. Mukerjee S; Oliver KD; Seila RL; Jacumin HH; Croghan C; Daughtrey EH; Neas LM; Smith LA J Environ Monit; 2009 Jan; 11(1):220-7. PubMed ID: 19137161 [TBL] [Abstract][Full Text] [Related]
54. A new system of refillable and uniquely identifiable diffusion tubes for dynamically generating VOC and SVOC standard atmospheres at ppm and ppb concentrations for calibration of field and laboratory measurements. Thompson JM; Perry DB J Environ Monit; 2009 Aug; 11(8):1543-4. PubMed ID: 19657541 [TBL] [Abstract][Full Text] [Related]
55. Selectivity enhancement for high-speed GC analysis of volatile organic compounds with portable instruments designed for vacuum-outlet and atmospheric-pressure inlet operation using air as the carrier gas. Whiting J; Sacks R Anal Chem; 2002 Jan; 74(1):246-52. PubMed ID: 11795802 [TBL] [Abstract][Full Text] [Related]
56. Evaluation of a portable gas chromatograph with photoionization detector under variations of VOC concentration, temperature, and relative humidity. Soo JC; Lee EG; LeBouf RF; Kashon ML; Chisholm W; Harper M J Occup Environ Hyg; 2018 Apr; 15(4):351-360. PubMed ID: 29333991 [TBL] [Abstract][Full Text] [Related]
57. Advances in offline approaches for chemically speciated measurements of trace gas-phase organic compounds via adsorbent tubes in an integrated sampling-to-analysis system. Sheu R; Marcotte A; Khare P; Charan S; Ditto JC; Gentner DR J Chromatogr A; 2018 Nov; 1575():80-90. PubMed ID: 30292521 [TBL] [Abstract][Full Text] [Related]
58. Analysis of solvent vapors in breath and ambient air with a surface acoustic wave sensor array. Groves WA; Zellers ET Ann Occup Hyg; 2001 Nov; 45(8):609-23. PubMed ID: 11718657 [TBL] [Abstract][Full Text] [Related]
59. Gas chromatography system for the automated, unattended, and cryogen-free monitoring of C2 to C6 non-methane hydrocarbons in the remote troposphere. Tanner D; Helmig D; Hueber J; Goldan P J Chromatogr A; 2006 Apr; 1111(1):76-88. PubMed ID: 16497314 [TBL] [Abstract][Full Text] [Related]
60. Evaluation of a new miniaturized ion mobility spectrometer and its coupling to fast gas chromatography multicapillary columns. Aguilera-Herrador E; Cárdenas S; Ruzsanyi V; Sielemann S; Valcárcel M J Chromatogr A; 2008 Dec; 1214(1-2):143-50. PubMed ID: 18986656 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]