59 related articles for article (PubMed ID: 1917403)
1. Accuracy of topographic measurements in a model eye with the laser tomographic scanner.
Dreher AW; Weinreb RN
Invest Ophthalmol Vis Sci; 1991 Oct; 32(11):2992-6. PubMed ID: 1917403
[TBL] [Abstract][Full Text] [Related]
2. [Comparison of two laser scanning tomography systems for three-dimensional analysis of the optic papilla].
Rohrschneider K; Burk RO; Völcker HE
Ophthalmologe; 1993 Dec; 90(6):613-9. PubMed ID: 8124023
[TBL] [Abstract][Full Text] [Related]
3. [3-dimensional biomorphometry of the papilla using a laser tomography scanning procedure--initial experiences with pathologic papillar findings].
Kruse FE; Burk RO; Völcker HE; Zinser G; Harbarth U
Fortschr Ophthalmol; 1989; 86(6):710-3. PubMed ID: 2625304
[TBL] [Abstract][Full Text] [Related]
4. [The Heidelberg Retina Tomograph: reproducibility and measuring errors in different pupillary widths using a model eye].
Janknecht P; Funk J
Klin Monbl Augenheilkd; 1994 Aug; 205(2):98-102. PubMed ID: 7967413
[TBL] [Abstract][Full Text] [Related]
5. Detection of structural damage from glaucoma with confocal laser image analysis.
Uchida H; Brigatti L; Caprioli J
Invest Ophthalmol Vis Sci; 1996 Nov; 37(12):2393-401. PubMed ID: 8933756
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of topographic measurements with the Optic Nerve Head Analyzer.
Shields MB; Tiedeman JS; Miller KN; Hickingbotham D; Ollie AR
Am J Ophthalmol; 1989 Mar; 107(3):273-9. PubMed ID: 2923153
[TBL] [Abstract][Full Text] [Related]
7. Improving the repeatability of topographic height measurements in confocal scanning laser imaging using maximum-likelihood deconvolution.
Patterson AJ; Garway-Heath DF; Crabb DP
Invest Ophthalmol Vis Sci; 2006 Oct; 47(10):4415-21. PubMed ID: 17003434
[TBL] [Abstract][Full Text] [Related]
8. An investigation of laser scanning techniques for quantifying changes in facial soft-tissue volume.
Wilson I; Snape L; Fright R; Nixon M
N Z Dent J; 1997 Dec; 93(414):110-3. PubMed ID: 9470442
[TBL] [Abstract][Full Text] [Related]
9. Scanning laser tomography: effect of change in keratometry values on retinal distance measures.
Hosking S; Flanagan J
Ophthalmic Physiol Opt; 1998 May; 18(3):294-8. PubMed ID: 9829117
[TBL] [Abstract][Full Text] [Related]
10. Improved reproducibility of measurements with the nerve fiber analyzer.
Tjon-Fo-Sang MJ; van Strik R; de Vries J; Lemij HG
J Glaucoma; 1997 Aug; 6(4):203-11. PubMed ID: 9264298
[TBL] [Abstract][Full Text] [Related]
11. Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry.
Hoh ST; Ishikawa H; Greenfield DS; Liebmann JM; Chew SJ; Ritch R
J Glaucoma; 1998 Feb; 7(1):12-5. PubMed ID: 9493109
[TBL] [Abstract][Full Text] [Related]
12. [Laser scanning in ophthalmology].
Jean B; Frohn A; Thiel HJ
Fortschr Ophthalmol; 1990; 87(2):158-67. PubMed ID: 2192974
[TBL] [Abstract][Full Text] [Related]
13. The confocal scanning laser ophthalmoscopy ancillary study to the ocular hypertension treatment study: study design and baseline factors.
Zangwill LM; Weinreb RN; Berry CC; Smith AR; Dirkes KA; Liebmann JM; Brandt JD; Trick G; Cioffi GA; Coleman AL; Piltz-Seymour JR; Gordon MO; Kass MA;
Am J Ophthalmol; 2004 Feb; 137(2):219-27. PubMed ID: 14962409
[TBL] [Abstract][Full Text] [Related]
14. The accuracy of a 3-D laser scanner for crown width measurements.
Nouri M; Massudi R; Bagheban AA; Azimi S; Fereidooni F
Aust Orthod J; 2009 May; 25(1):41-7. PubMed ID: 19634463
[TBL] [Abstract][Full Text] [Related]
15. Correlation of blue-on-yellow visual fields with scanning confocal laser optic disc measurements.
Teesalu P; Vihanninjoki K; Airaksinen PJ; Tuulonen A; Läärä E
Invest Ophthalmol Vis Sci; 1997 Nov; 38(12):2452-9. PubMed ID: 9375562
[TBL] [Abstract][Full Text] [Related]
16. The effect of excimer laser photorefractive keratectomy for myopia on nerve fiber layer thickness measurements as determined by scanning laser polarimetry.
Choplin NT; Schallhorn SC
Ophthalmology; 1999 May; 106(5):1019-23. PubMed ID: 10328407
[TBL] [Abstract][Full Text] [Related]
17. Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy.
Leung CK; Cheng AC; Chong KK; Leung KS; Mohamed S; Lau CS; Cheung CY; Chu GC; Lai RY; Pang CC; Lam DS
Invest Ophthalmol Vis Sci; 2007 Jul; 48(7):3178-83. PubMed ID: 17591887
[TBL] [Abstract][Full Text] [Related]
18. Interocular differences in optic disc topographic parameters in normal subjects.
Gherghel D; Orgül S; Prünte C; Gugleta K; Lübeck P; Gekkieva M; Flammer J
Curr Eye Res; 2000 Apr; 20(4):276-82. PubMed ID: 10806441
[TBL] [Abstract][Full Text] [Related]
19. Laser-tissue interaction and artifacts in confocal scanning laser ophthalmoscopy and tomography.
Bartsch DU; Freeman WR
Neurosci Biobehav Rev; 1993; 17(4):459-67. PubMed ID: 8309654
[TBL] [Abstract][Full Text] [Related]
20. Reproducibility of topometric data with a scanning laser ophthalmoscope in rabbits.
Orgül S; Cioffi GA; Bacon DR; van Buskirk EM
Jpn J Ophthalmol; 1995; 39(4):438-42. PubMed ID: 8926653
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]