These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

83 related articles for article (PubMed ID: 19174348)

  • 1. Accuracy of ultrasound measurements for skull bone thickness using coded signals.
    Tretbar SH; Plinkert PK; Federspil PA
    IEEE Trans Biomed Eng; 2009 Mar; 56(3):733-40. PubMed ID: 19174348
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of skull bone thickness for bone-anchored hearing aids: an experimental study comparing both a novel ultrasound system (SonoPointer) and computed tomographic scanning to mechanical measurements.
    Federspil PA; Tretbar SH; Böhlen FH; Rohde S; Glaser S; Plinkert PK
    Otol Neurotol; 2010 Apr; 31(3):440-6. PubMed ID: 20118817
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasound in the assessment of cranial bone thickness.
    Elahi MM; Lessard ML; Hakim S; Watkin K; Sampalis J
    J Craniofac Surg; 1997 May; 8(3):213-21. PubMed ID: 9482069
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new predictive modality of cranial bone thickness.
    Elahi MM; Watkin KL; Hakim MS; Schloss MD; Lessard ML
    Ann Plast Surg; 1999 Jun; 42(6):651-7. PubMed ID: 10382803
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A-mode ultrasound-based registration in computer-aided surgery of the skull.
    Amstutz C; Caversaccio M; Kowal J; Bächler R; Nolte LP; Häusler R; Styner M
    Arch Otolaryngol Head Neck Surg; 2003 Dec; 129(12):1310-6. PubMed ID: 14676157
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Measurement of skull thickness by ultrasound].
    Stölzel K; Bauknecht C; Wernecke K; Schrom T
    Laryngorhinootologie; 2007 Feb; 86(2):107-11. PubMed ID: 17131256
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of a practical ultrasonic approach for simultaneous measurement of the thickness and the sound speed in human skull bones: a laboratory phantom study.
    Wydra A; Malyarenko E; Shapoori K; Maev RG
    Phys Med Biol; 2013 Feb; 58(4):1083-102. PubMed ID: 23363729
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accurate 3-D Profile Extraction of Skull Bone Using an Ultrasound Matrix Array.
    Hajian M; Gaspar R; Maev RG
    IEEE Trans Biomed Eng; 2017 Dec; 64(12):2858-2871. PubMed ID: 28287955
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The thickness measurement of alive human skull based on CT image].
    Li H; Ruan S; Peng X; Xie Z; Wang H; Liu W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Oct; 24(5):964-8, 980. PubMed ID: 18027676
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications.
    Cavalcanti MG; Rocha SS; Vannier MW
    Dentomaxillofac Radiol; 2004 May; 33(3):170-6. PubMed ID: 15371317
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program.
    Periago DR; Scarfe WC; Moshiri M; Scheetz JP; Silveira AM; Farman AG
    Angle Orthod; 2008 May; 78(3):387-95. PubMed ID: 18416632
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-dimensional measurement accuracy of skull surface landmarks.
    Hildebolt CF; Vannier MW
    Am J Phys Anthropol; 1988 Aug; 76(4):497-503. PubMed ID: 3218672
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Considerations associated with computer forensic facial reconstructions the limits of soft tissues' thickness determination.
    Chistol RO; Furnică C; Moraru M
    Rev Med Chir Soc Med Nat Iasi; 2009; 113(3):757-61. PubMed ID: 20191828
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull.
    Berco M; Rigali PH; Miner RM; DeLuca S; Anderson NK; Will LA
    Am J Orthod Dentofacial Orthop; 2009 Jul; 136(1):17.e1-9; discussion 17-8. PubMed ID: 19577142
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transcranial shear-mode ultrasound: assessment of imaging performance and excitation techniques.
    Yousefi A; Goertz DE; Hynynen K
    IEEE Trans Med Imaging; 2009 May; 28(5):763-74. PubMed ID: 19150789
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom).
    Lascala CA; Panella J; Marques MM
    Dentomaxillofac Radiol; 2004 Sep; 33(5):291-4. PubMed ID: 15585804
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrasonic measurement of bone thickness for spinal surgery.
    Yamada M; Moriya H; Iino T; Kasai Y; Sudo A; Uchida A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Sep; 59(9):2077-88. PubMed ID: 23007783
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional cephalometry using helical computer tomography: measurement error caused by head inclination.
    Togashi K; Kitaura H; Yonetsu K; Yoshida N; Nakamura T
    Angle Orthod; 2002 Dec; 72(6):513-20. PubMed ID: 12518942
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The measurement and analyses of symmetry characteristic of human skull based on CT images].
    Li H; Xie Z; Ruan S; Wang H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Feb; 26(1):34-7. PubMed ID: 19334549
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A method of magnification correction for posteroanterior radiographic cephalometry.
    Hsiao TH; Chang HP; Liu KM
    Angle Orthod; 1997; 67(2):137-42. PubMed ID: 9107378
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.