BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 19174776)

  • 1. Xoft Axxent electronic brachytherapy: a new device for delivering brachytherapy to the breast.
    Dickler A
    Nat Clin Pract Oncol; 2009 Mar; 6(3):138-42. PubMed ID: 19174776
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Xoft Axxent electronic brachytherapy.
    Dickler A; Dowlatshahi K
    Expert Rev Med Devices; 2009 Jan; 6(1):27-31. PubMed ID: 19105777
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modeling study for optimization of skin dose for partial breast irradiation using Xoft Axxent electronic brachytherapy applicator.
    Hepel JT; Hiatt JR; Cardarelli GA; Wazer DE
    Brachytherapy; 2010; 9(1):81-5. PubMed ID: 19850533
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A dosimetric comparison of MammoSite high-dose-rate brachytherapy and Xoft Axxent electronic brachytherapy.
    Dickler A; Kirk MC; Seif N; Griem K; Dowlatshahi K; Francescatti D; Abrams RA
    Brachytherapy; 2007; 6(2):164-8. PubMed ID: 17434111
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source.
    White SA; Landry G; Fonseca GP; Holt R; Rusch T; Beaulieu L; Verhaegen F; Reniers B
    Med Phys; 2014 Jun; 41(6):061701. PubMed ID: 24877796
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A dosimetric comparison of Xoft Axxent Electronic Brachytherapy and iridium-192 high-dose-rate brachytherapy in the treatment of endometrial cancer.
    Dickler A; Kirk MC; Coon A; Bernard D; Zusag T; Rotmensch J; Wazer DE
    Brachytherapy; 2008; 7(4):351-4. PubMed ID: 18783991
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of organ doses for patients undergoing balloon brachytherapy of the breast with HDR 192Ir or electronic sources using monte carlo simulations in a heterogeneous human phantom.
    Mille MM; Xu XG; Rivard MJ
    Med Phys; 2010 Feb; 37(2):662-71. PubMed ID: 20229875
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of dose enhancement factor for Xoft Axxent electronic brachytherapy device using nanoparticle-embedded alginate film and radiochromic film.
    Kakade NR; Das A; Kumar R; Sharma SD; Maiti N; Chadha R; Sapra BK
    J Cancer Res Ther; 2023 Apr; 19(Supplement):S0. PubMed ID: 37147944
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric effects of saline- versus water-filled balloon applicators for IORT using the model S700 electronic brachytherapy source.
    Redler G; Templeton A; Zhen H; Turian J; Bernard D; Chu JCH; Griem KL; Liao Y
    Brachytherapy; 2018; 17(2):500-505. PubMed ID: 29229377
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative radiation therapy in the treatment of early-stage breast cancer utilizing xoft axxent electronic brachytherapy.
    Dickler A; Ivanov O; Francescatti D
    World J Surg Oncol; 2009 Mar; 7():24. PubMed ID: 19254369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intraoperative Radiotherapy with Balloon-Based Electronic Brachytherapy System-A Systematic Review and First Bulgarian Experience in Breast Cancer Patients.
    Kostova-Lefterova D; Vasileva-Slaveva M; Maslyankov S; Konsoulova A; Atanasova M; Paycheva T; Vlahova A; Genadieva-Yordanova M; Prodanova G; Zahariev Z; Pavlov V; Todorov G; Vasilev B; Angelov K; Deliyski T; Petrova I; Hitova D; Petrov I
    Curr Oncol; 2021 Oct; 28(5):3932-3944. PubMed ID: 34677253
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Five-year results: the initial clinical trial of MammoSite balloon brachytherapy for partial breast irradiation in early-stage breast cancer.
    Benitez PR; Keisch ME; Vicini F; Stolier A; Scroggins T; Walker A; White J; Hedberg P; Hebert M; Arthur D; Zannis V; Quiet C; Streeter O; Silverstein M
    Am J Surg; 2007 Oct; 194(4):456-62. PubMed ID: 17826055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiation recall reaction with docetaxel administration after accelerated partial breast irradiation with electronic brachytherapy.
    Chen SS; Strauss JB; Shah AP; Rao RD; Bernard DA; Griem KL
    Brachytherapy; 2009; 8(3):331-4. PubMed ID: 19446501
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design and dosimetric characteristics of a new endocavitary contact radiotherapy system using an electronic brachytherapy source.
    Richardson S; Garcia-Ramirez J; Lu W; Myerson RJ; Parikh P
    Med Phys; 2012 Nov; 39(11):6838-46. PubMed ID: 23127076
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preliminary results and evaluation of MammoSite balloon brachytherapy for partial breast irradiation for pure ductal carcinoma in situ: a phase II clinical study.
    Benitez PR; Streeter O; Vicini F; Mehta V; Quiet C; Kuske R; Hayes MK; Arthur D; Kuerer H; Freedman G; Keisch M; Dipetrillo T; Khan D; Hudes R
    Am J Surg; 2006 Oct; 192(4):427-33. PubMed ID: 16978943
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of tumor and normal tissue dose for accelerated partial breast irradiation using an electronic brachytherapy eBx source and an Iridium-192 source.
    Ahmad S; Johnson D; Hiatt JR; Still DT; Furhang EE; Marsden D; Kearly F; Bernard DA; Holt RW
    J Appl Clin Med Phys; 2010 Sep; 11(4):3301. PubMed ID: 21081891
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric comparison of the INTRABEAM and Axxent for intraoperative breast radiotherapy.
    Shaikh MY; Tanny S
    Brachytherapy; 2020; 19(2):234-240. PubMed ID: 31879239
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of the relative biological effectiveness of low energy electronic brachytherapy sources in breast tissue: a Monte Carlo study.
    White SA; Reniers B; de Jong EE; Rusch T; Verhaegen F
    Phys Med Biol; 2016 Jan; 61(1):383-99. PubMed ID: 26674746
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Axxent-Xoft, (192)Ir and (60)Co high-dose-rate brachytherapy sources for image-guided brachytherapy treatment planning for cervical cancer.
    Mobit PN; Packianathan S; He R; Yang CC
    Br J Radiol; 2015 Aug; 88(1052):20150010. PubMed ID: 25996576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Applications of tissue heterogeneity corrections and biologically effective dose volume histograms in assessing the doses for accelerated partial breast irradiation using an electronic brachytherapy source.
    Shi C; Guo B; Cheng CY; Eng T; Papanikolaou N
    Phys Med Biol; 2010 Sep; 55(18):5283-97. PubMed ID: 20720283
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.