300 related articles for article (PubMed ID: 19175081)
1. Three-dimensional linear system analysis for breast tomosynthesis.
Zhao B; Zhao W
Med Phys; 2008 Dec; 35(12):5219-32. PubMed ID: 19175081
[TBL] [Abstract][Full Text] [Related]
2. Experimental validation of a three-dimensional linear system model for breast tomosynthesis.
Zhao B; Zhou J; Hu YH; Mertelmeier T; Ludwig J; Zhao W
Med Phys; 2009 Jan; 36(1):240-51. PubMed ID: 19235392
[TBL] [Abstract][Full Text] [Related]
3. Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach.
Hu YH; Zhao B; Zhao W
Med Phys; 2008 Dec; 35(12):5242-52. PubMed ID: 19175083
[TBL] [Abstract][Full Text] [Related]
4. The effect of amorphous selenium detector thickness on dual-energy digital breast imaging.
Hu YH; Zhao W
Med Phys; 2014 Nov; 41(11):111904. PubMed ID: 25370637
[TBL] [Abstract][Full Text] [Related]
5. Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system.
Zhao B; Zhao W
Med Phys; 2008 May; 35(5):1978-87. PubMed ID: 18561674
[TBL] [Abstract][Full Text] [Related]
6. Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.
Berggren K; Cederström B; Lundqvist M; Fredenberg E
Med Phys; 2018 Oct; 45(10):4392-4401. PubMed ID: 30091470
[TBL] [Abstract][Full Text] [Related]
7. A computer simulation platform for the optimization of a breast tomosynthesis system.
Zhou J; Zhao B; Zhao W
Med Phys; 2007 Mar; 34(3):1098-109. PubMed ID: 17441255
[TBL] [Abstract][Full Text] [Related]
8. Oblique reconstructions in tomosynthesis. I. Linear systems theory.
Acciavatti RJ; Maidment AD
Med Phys; 2013 Nov; 40(11):111911. PubMed ID: 24320444
[TBL] [Abstract][Full Text] [Related]
9. Three-dimensional cascaded system analysis of a 50 µm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.
Zhao C; Vassiljev N; Konstantinidis AC; Speller RD; Kanicki J
Phys Med Biol; 2017 Mar; 62(5):1994-2017. PubMed ID: 28072394
[TBL] [Abstract][Full Text] [Related]
10. Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.
Zhao W; Ji WG; Debrie A; Rowlands JA
Med Phys; 2003 Feb; 30(2):254-63. PubMed ID: 12607843
[TBL] [Abstract][Full Text] [Related]
11. Quantitative image quality measurements of a digital breast tomosynthesis system.
Olgar T; Kahn T; Gosch D
Rofo; 2013 Dec; 185(12):1188-94. PubMed ID: 23888475
[TBL] [Abstract][Full Text] [Related]
12. Oblique reconstructions in tomosynthesis. II. Super-resolution.
Acciavatti RJ; Maidment AD
Med Phys; 2013 Nov; 40(11):111912. PubMed ID: 24320445
[TBL] [Abstract][Full Text] [Related]
13. Observation of super-resolution in digital breast tomosynthesis.
Acciavatti RJ; Maidment AD
Med Phys; 2012 Dec; 39(12):7518-39. PubMed ID: 23231301
[TBL] [Abstract][Full Text] [Related]
14. Image quality of microcalcifications in digital breast tomosynthesis: effects of projection-view distributions.
Lu Y; Chan HP; Wei J; Goodsitt M; Carson PL; Hadjiiski L; Schmitz A; Eberhard JW; Claus BE
Med Phys; 2011 Oct; 38(10):5703-12. PubMed ID: 21992385
[TBL] [Abstract][Full Text] [Related]
15. Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.
Tward DJ; Siewerdsen JH
Med Phys; 2008 Dec; 35(12):5510-29. PubMed ID: 19175110
[TBL] [Abstract][Full Text] [Related]
16. In-plane image quality and NPWE detectability index in digital breast tomosynthesis.
Monnin P; Verdun FR; Bosmans H; Marshall NW
Phys Med Biol; 2020 May; 65(9):095013. PubMed ID: 32191923
[TBL] [Abstract][Full Text] [Related]
17. The effect of angular dose distribution on the detection of microcalcifications in digital breast tomosynthesis.
Hu YH; Zhao W
Med Phys; 2011 May; 38(5):2455-66. PubMed ID: 21776781
[TBL] [Abstract][Full Text] [Related]
18. Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency.
Zhao W; Rowlands JA
Med Phys; 1997 Dec; 24(12):1819-33. PubMed ID: 9434965
[TBL] [Abstract][Full Text] [Related]
19. 50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.
Zhao C; Konstantinidis AC; Zheng Y; Anaxagoras T; Speller RD; Kanicki J
Phys Med Biol; 2015 Dec; 60(23):8977-9001. PubMed ID: 26540090
[TBL] [Abstract][Full Text] [Related]
20. Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: relevance to morphology of structures such as microcalcifications.
Chen Y; Lo JY; Dobbins JT
Med Phys; 2007 Oct; 34(10):3885-92. PubMed ID: 17985634
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]