BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

467 related articles for article (PubMed ID: 19175095)

  • 1. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
    Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
    Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Fricke dosimeter as an absorbed dose to water primary standard for Ir-192 brachytherapy.
    El Gamal I; Cojocaru C; Mainegra-Hing E; McEwen M
    Phys Med Biol; 2015 Jun; 60(11):4481-95. PubMed ID: 25988983
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A feasibility study of Fricke dosimetry as an absorbed dose to water standard for 192Ir HDR sources.
    deAlmeida CE; Ochoa R; Lima MC; David MG; Pires EJ; Peixoto JG; Salata C; Bernal MA
    PLoS One; 2014; 9(12):e115155. PubMed ID: 25521914
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.
    Ho Than MT; Munro Iii JJ; Medich DC
    J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte Carlo dosimetry of the microselectron HDR 192Ir brachytherapy source using MCNP4A.
    Wallace S; Wong T; Fernando W
    Australas Phys Eng Sci Med; 1998 Mar; 21(1):11-7. PubMed ID: 9633148
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system.
    Austerlitz C; Campos CA
    Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validating Fricke dosimetry for the measurement of absorbed dose to water for HDR
    Salata C; David MG; de Almeida CE; El Gamal I; Cojocaru C; Mainegra-Hing E; McEwen M
    Phys Med Biol; 2018 Apr; 63(8):085004. PubMed ID: 29488467
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Air-kerma strength determination of an HDR
    Smith BR; Micka JA; Aima M; DeWerd LA; Culberson WS
    Med Phys; 2017 Jan; 44(1):311-320. PubMed ID: 28102953
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of absorbed dose-to-water for an HDR (192)Ir source with ionization chambers in a sandwich setup.
    Araki F; Kouno T; Ohno T; Kakei K; Yoshiyama F; Kawamura S
    Med Phys; 2013 Sep; 40(9):092101. PubMed ID: 24007170
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
    Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
    Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quality assurance of HDR 192Ir sources using a Fricke dosimeter.
    Austerlitz C; Mota H; Almeida CE; Allison R; Sibata C
    Med Phys; 2007 Apr; 34(4):1348-53. PubMed ID: 17500465
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of the correction factors used in Fricke dosimetry for HDR
    David MG; Salata C; de Almeida CE
    Phys Med; 2021 Apr; 84():50-55. PubMed ID: 33845419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
    Bannon EA; Yang Y; Rivard MJ
    Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192Ir sources.
    Williamson JF; Li Z
    Med Phys; 1995 Jun; 22(6):809-19. PubMed ID: 7565372
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose characterization in the near-source region for two high dose rate brachytherapy sources.
    Wang R; Li XA
    Med Phys; 2002 Aug; 29(8):1678-86. PubMed ID: 12201413
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.
    Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P
    Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources.
    Antonovic L; Gustafsson H; Carlsson GA; Carlsson Tedgren A
    Med Phys; 2009 Jun; 36(6):2236-47. PubMed ID: 19610313
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate
    Kaveckyte V; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2018 Jan; 45(1):429-437. PubMed ID: 29171060
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In-water calibration of PDR 192Ir brachytherapy sources with an NE2571 ionization chamber.
    Reynaert N; Verhaegen F; Thierens H
    Phys Med Biol; 1998 Aug; 43(8):2095-107. PubMed ID: 9725592
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a water calorimetry-based standard for absorbed dose to water in HDR 192Ir brachytherapy.
    Sarfehnia A; Seuntjens J
    Med Phys; 2010 Apr; 37(4):1914-23. PubMed ID: 20443513
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.