175 related articles for article (PubMed ID: 19175130)
21. In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: feasibility study.
Reniers B; Landry G; Eichner R; Hallil A; Verhaegen F
Med Phys; 2012 Apr; 39(4):1925-35. PubMed ID: 22482614
[TBL] [Abstract][Full Text] [Related]
22. On the use of HDR 60Co source with the MammoSite radiation therapy system.
Baltas D; Lymperopoulou G; Zamboglou N
Med Phys; 2008 Dec; 35(12):5263-8. PubMed ID: 19175085
[TBL] [Abstract][Full Text] [Related]
23. Dosimetry investigation of MOSFET for clinical IMRT dose verification.
Deshpande S; Kumar R; Ghadi Y; Neharu RM; Kannan V
Technol Cancer Res Treat; 2013 Jun; 12(3):193-8. PubMed ID: 23369153
[TBL] [Abstract][Full Text] [Related]
24. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
[TBL] [Abstract][Full Text] [Related]
25. Preliminary evaluation of implantable MOSFET radiation dosimeters.
Beddar AS; Salehpour M; Briere TM; Hamidian H; Gillin MT
Phys Med Biol; 2005 Jan; 50(1):141-9. PubMed ID: 15715428
[TBL] [Abstract][Full Text] [Related]
26. Characterization of responses and comparison of calibration factor for commercial MOSFET detectors.
Bharanidharan G; Manigandan D; Devan K; Subramani V; Gopishankar N; Ganesh T; Joshi R; Rath G; Velmurugan J; Aruna P; Ganesan S
Med Dosim; 2005; 30(4):213-8. PubMed ID: 16275563
[TBL] [Abstract][Full Text] [Related]
27. Characterization of MOSkin detector for in vivo dose verification during Cobalt-60 high dose-rate intracavitary brachytherapy.
Jamalludin Z; Jong WL; Abdul Malik R; Rosenfeld A; Ung NM
Phys Med; 2019 Feb; 58():1-7. PubMed ID: 30824140
[TBL] [Abstract][Full Text] [Related]
28. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system.
Austerlitz C; Campos CA
Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456
[TBL] [Abstract][Full Text] [Related]
29. A feasibility study of Fricke dosimetry as an absorbed dose to water standard for 192Ir HDR sources.
deAlmeida CE; Ochoa R; Lima MC; David MG; Pires EJ; Peixoto JG; Salata C; Bernal MA
PLoS One; 2014; 9(12):e115155. PubMed ID: 25521914
[TBL] [Abstract][Full Text] [Related]
30. Clinical application of radiophotoluminescent glass dosimeter for dose verification of prostate HDR procedure.
Hsu SM; Yeh CY; Yeh TC; Hong JH; Tipton AY; Chen WL; Sun SS; Huang DY
Med Phys; 2008 Dec; 35(12):5558-64. PubMed ID: 19175113
[TBL] [Abstract][Full Text] [Related]
31. Dosimetric characteristics of a single use MOSFET dosimeter for in vivo dosimetry in proton therapy.
Cheng CW; Wolanski M; Zhao Q; Fanelli L; Gautam A; Pack D; Das IJ
Med Phys; 2010 Aug; 37(8):4266-73. PubMed ID: 20879587
[TBL] [Abstract][Full Text] [Related]
32. Characterization of microMOSFET detectors for in vivo dosimetry in high-dose-rate brachytherapy with
Ruiz-Arrebola S; Fabregat-Borrás R; Rodríguez E; Fernández-Montes M; Pérez-Macho M; Ferri M; García A; Cardenal J; Pacheco MT; Anchuelo J; Tornero-López AM; Prada PJ; Guirado D
Med Phys; 2020 Jun; 47(5):2242-2253. PubMed ID: 32031263
[TBL] [Abstract][Full Text] [Related]
33. Quality assurance of HDR 192Ir sources using a Fricke dosimeter.
Austerlitz C; Mota H; Almeida CE; Allison R; Sibata C
Med Phys; 2007 Apr; 34(4):1348-53. PubMed ID: 17500465
[TBL] [Abstract][Full Text] [Related]
34. Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy.
Andersen CE; Nielsen SK; Lindegaard JC; Tanderup K
Med Phys; 2009 Nov; 36(11):5033-43. PubMed ID: 19994514
[TBL] [Abstract][Full Text] [Related]
35. An in-house developed resettable MOSFET dosimeter for radiotherapy.
Verellen D; Van Vaerenbergh S; Tournel K; Heuninckx K; Joris L; Duchateau M; Linthout N; Gevaert T; Reynders T; Van de Vondel I; Coppens L; Depuydt T; De Ridder M; Storme G
Phys Med Biol; 2010 Feb; 55(4):N97-109. PubMed ID: 20090184
[TBL] [Abstract][Full Text] [Related]
36. Development of a scatter correction technique and its application to HDR 192Ir multicatheter breast brachytherapy.
Poon E; Verhaegen F
Med Phys; 2009 Aug; 36(8):3703-13. PubMed ID: 19746803
[TBL] [Abstract][Full Text] [Related]
37. Dosimetric characterization of a novel intracavitary mold applicator for 192Ir high dose rate endorectal brachytherapy treatment.
Poon E; Reniers B; Devic S; Vuong T; Verhaegen F
Med Phys; 2006 Dec; 33(12):4515-26. PubMed ID: 17278803
[TBL] [Abstract][Full Text] [Related]
38. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
[TBL] [Abstract][Full Text] [Related]
39. Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry.
Casey KE; Alvarez P; Kry SF; Howell RM; Lawyer A; Followill D
Med Phys; 2013 Nov; 40(11):112102. PubMed ID: 24320455
[TBL] [Abstract][Full Text] [Related]
40. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]