BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

330 related articles for article (PubMed ID: 19176558)

  • 1. Retention time alignment algorithms for LC/MS data must consider non-linear shifts.
    Podwojski K; Fritsch A; Chamrad DC; Paul W; Sitek B; Stühler K; Mutzel P; Stephan C; Meyer HE; Urfer W; Ickstadt K; Rahnenführer J
    Bioinformatics; 2009 Mar; 25(6):758-64. PubMed ID: 19176558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A geometric approach for the alignment of liquid chromatography-mass spectrometry data.
    Lange E; Gröpl C; Schulz-Trieglaff O; Leinenbach A; Huber C; Reinert K
    Bioinformatics; 2007 Jul; 23(13):i273-81. PubMed ID: 17646306
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust algorithm for alignment of liquid chromatography-mass spectrometry analyses in an accurate mass and time tag data analysis pipeline.
    Jaitly N; Monroe ME; Petyuk VA; Clauss TR; Adkins JN; Smith RD
    Anal Chem; 2006 Nov; 78(21):7397-409. PubMed ID: 17073405
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Semi-supervised LC/MS alignment for differential proteomics.
    Fischer B; Grossmann J; Roth V; Gruissem W; Baginsky S; Buhmann JM
    Bioinformatics; 2006 Jul; 22(14):e132-40. PubMed ID: 16873463
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Time alignment algorithms based on selected mass traces for complex LC-MS data.
    Christin C; Hoefsloot HC; Smilde AK; Suits F; Bischoff R; Horvatovich PL
    J Proteome Res; 2010 Mar; 9(3):1483-95. PubMed ID: 20070124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated image alignment for 2D gel electrophoresis in a high-throughput proteomics pipeline.
    Dowsey AW; Dunn MJ; Yang GZ
    Bioinformatics; 2008 Apr; 24(7):950-7. PubMed ID: 18310057
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MassUntangler: a novel alignment tool for label-free liquid chromatography-mass spectrometry proteomic data.
    Ballardini R; Benevento M; Arrigoni G; Pattini L; Roda A
    J Chromatogr A; 2011 Dec; 1218(49):8859-68. PubMed ID: 21783198
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aligning LC peaks by converting gradient retention times to retention index of peptides in proteomic experiments.
    Shinoda K; Tomita M; Ishihama Y
    Bioinformatics; 2008 Jul; 24(14):1590-5. PubMed ID: 18492686
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Alignment of LC-MS images, with applications to biomarker discovery and protein identification.
    Vandenbogaert M; Li-Thiao-Té S; Kaltenbach HM; Zhang R; Aittokallio T; Schwikowski B
    Proteomics; 2008 Feb; 8(4):650-72. PubMed ID: 18297649
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Data pre-processing in liquid chromatography-mass spectrometry-based proteomics.
    Zhang X; Asara JM; Adamec J; Ouzzani M; Elmagarmid AK
    Bioinformatics; 2005 Nov; 21(21):4054-9. PubMed ID: 16150809
    [TBL] [Abstract][Full Text] [Related]  

  • 11. MSSimulator: Simulation of mass spectrometry data.
    Bielow C; Aiche S; Andreotti S; Reinert K
    J Proteome Res; 2011 Jul; 10(7):2922-9. PubMed ID: 21526843
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An iterative strategy for precursor ion selection for LC-MS/MS based shotgun proteomics.
    Zerck A; Nordhoff E; Resemann A; Mirgorodskaya E; Suckau D; Reinert K; Lehrach H; Gobom J
    J Proteome Res; 2009 Jul; 8(7):3239-51. PubMed ID: 19402737
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Shape-based feature matching improves protein identification via LC-MS and tandem MS.
    Noy K; Towfic F; Wittenberg GM; Fasulo D
    J Comput Biol; 2011 Apr; 18(4):547-57. PubMed ID: 21417940
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Highly accelerated feature detection in proteomics data sets using modern graphics processing units.
    Hussong R; Gregorius B; Tholey A; Hildebrandt A
    Bioinformatics; 2009 Aug; 25(15):1937-43. PubMed ID: 19447788
    [TBL] [Abstract][Full Text] [Related]  

  • 15. CLUE-TIPS, clustering methods for pattern analysis of LC-MS data.
    Akella LM; Rejtar T; Orazine C; Hincapie M; Hancock WS
    J Proteome Res; 2009 Oct; 8(10):4732-42. PubMed ID: 19725534
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optimized time alignment algorithm for LC-MS data: correlation optimized warping using component detection algorithm-selected mass chromatograms.
    Christin C; Smilde AK; Hoefsloot HC; Suits F; Bischoff R; Horvatovich PL
    Anal Chem; 2008 Sep; 80(18):7012-21. PubMed ID: 18715018
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Difference detection in LC-MS data for protein biomarker discovery.
    Listgarten J; Neal RM; Roweis ST; Wong P; Emili A
    Bioinformatics; 2007 Jan; 23(2):e198-204. PubMed ID: 17237092
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Integration of two-dimensional LC-MS with multivariate statistics for comparative analysis of proteomic samples.
    Gaspari M; Verhoeckx KC; Verheij ER; van der Greef J
    Anal Chem; 2006 Apr; 78(7):2286-96. PubMed ID: 16579610
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chromatographic alignment of ESI-LC-MS proteomics data sets by ordered bijective interpolated warping.
    Prince JT; Marcotte EM
    Anal Chem; 2006 Sep; 78(17):6140-52. PubMed ID: 16944896
    [TBL] [Abstract][Full Text] [Related]  

  • 20. LC-MS/MS based proteomic analysis and functional inference of hypothetical proteins in Desulfovibrio vulgaris.
    Zhang W; Culley DE; Gritsenko MA; Moore RJ; Nie L; Scholten JC; Petritis K; Strittmatter EF; Camp DG; Smith RD; Brockman FJ
    Biochem Biophys Res Commun; 2006 Nov; 349(4):1412-9. PubMed ID: 16982031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.