157 related articles for article (PubMed ID: 19189222)
1. Technical performance and reflection capacity of the anaesthetic conserving device--a bench study with isoflurane and sevoflurane. Meiser A; Bellgardt M; Belda J; Röhm K; Laubenthal H; Sirtl C J Clin Monit Comput; 2009 Feb; 23(1):11-9. PubMed ID: 19189222 [TBL] [Abstract][Full Text] [Related]
2. Reflection efficiencies of AnaConDa-S and AnaConDa-100 for isoflurane under dry laboratory and simulated clinical conditions: a bench study using a test lung. Kermad A; Speltz J; Daume P; Volk T; Meiser A Expert Rev Med Devices; 2021 Feb; 18(2):189-195. PubMed ID: 33322972 [No Abstract] [Full Text] [Related]
3. [Functioning of the anaesthetic conserving device: aspects to consider for use in inhalational sedation]. Meiser A; Bellgardt M; Vogelsang H; Sirtl C; Weber T Anaesthesist; 2010 Nov; 59(11):1029-40. PubMed ID: 20878139 [TBL] [Abstract][Full Text] [Related]
4. AnaConDa reflection filter: bench and patient evaluation of safety and volatile anesthetic conservation. Berton J; Sargentini C; Nguyen JL; Belii A; Beydon L Anesth Analg; 2007 Jan; 104(1):130-4. PubMed ID: 17179257 [TBL] [Abstract][Full Text] [Related]
5. Increasing the reflection efficiency of the Sedaconda ACD-S by heating and cooling the anaesthetic reflector: a bench study using a test lung. Meiser A; Meis PLF; O'Gara B; Volk T; Kermad A J Clin Monit Comput; 2023 Jun; 37(3):919-924. PubMed ID: 36625981 [TBL] [Abstract][Full Text] [Related]
6. Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model. Bomberg H; Meiser F; Daume P; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A Anesth Analg; 2019 Aug; 129(2):371-379. PubMed ID: 29787413 [TBL] [Abstract][Full Text] [Related]
7. A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care. Farrell R; Oomen G; Carey P J Clin Monit Comput; 2018 Aug; 32(4):595-604. PubMed ID: 29388094 [TBL] [Abstract][Full Text] [Related]
8. Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilation. Sturesson LW; Bodelsson M; Jonson B; Malmkvist G Br J Anaesth; 2014 Sep; 113(3):508-14. PubMed ID: 24871871 [TBL] [Abstract][Full Text] [Related]
9. Halving the volume of AnaConDa: initial clinical experience with a new small-volume anaesthetic reflector in critically ill patients-a quality improvement project. Bomberg H; Meiser F; Zimmer S; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A J Clin Monit Comput; 2018 Aug; 32(4):639-646. PubMed ID: 29700664 [TBL] [Abstract][Full Text] [Related]
10. Sevoflurane output from the Oxford Miniature Vaporizer in drawover mode. Liu EH; Dhara SS Anaesth Intensive Care; 2000 Oct; 28(5):532-6. PubMed ID: 11094669 [TBL] [Abstract][Full Text] [Related]
11. Uncontrolled delivery of liquid volatile anaesthetic when using the anaesthetic conserving device. Karnjuš I; Mekiš D; Križmarić M J Clin Monit Comput; 2018 Aug; 32(4):629-638. PubMed ID: 28567612 [TBL] [Abstract][Full Text] [Related]
12. A pharmacokinetic study of 48-hour sevoflurane inhalation using a disposable delivery system (AnaConDa®) in ICU patients. Perbet S; Bourdeaux D; Sautou V; Pereira B; Chabanne R; Constantin JM; Chopineau J; Bazin JE Minerva Anestesiol; 2014 Jun; 80(6):655-65. PubMed ID: 24226486 [TBL] [Abstract][Full Text] [Related]
13. Mechanical ventilation of six dogs anaesthetised with isoflurane or sevoflurane delivered by a Komesaroff anaesthetic machine. Laredo FG; Belda E; Escobar M Vet Rec; 2009 Jun; 164(24):751-4. PubMed ID: 19525524 [TBL] [Abstract][Full Text] [Related]
14. [Low flow anaesthesia with isoflurane and sevoflurane in the dog]. Kramer S; Alyakine H; Nolte I Berl Munch Tierarztl Wochenschr; 2008; 121(1-2):53-65. PubMed ID: 18277780 [TBL] [Abstract][Full Text] [Related]
15. Preparation of Datex-Ohmeda Aestiva and Aisys anaesthetic machines for use in malignant hyperthermia susceptible patients. Jones C; Bennett K; Kim TW; Bulger TF; Pollock N Anaesth Intensive Care; 2012 May; 40(3):490-7. PubMed ID: 22577915 [TBL] [Abstract][Full Text] [Related]
16. Sevoflurane Output in the Isoflurane/Halothane Diamedica Draw-over Vaporiser. Tay WC; Tan WT Ann Acad Med Singap; 2015 Jul; 44(7):252-6. PubMed ID: 26377059 [TBL] [Abstract][Full Text] [Related]
17. The Reflector: a new method for saving anaesthetic vapours. Perhag L; Reinstrup P; Thomasson R; Werner O Br J Anaesth; 2000 Sep; 85(3):482-6. PubMed ID: 11103198 [TBL] [Abstract][Full Text] [Related]
18. Influence of 0.1 minimum alveolar concentration of sevoflurane, desflurane and isoflurane on dynamic ventilatory response to hypercapnia in humans. van den Elsen M; Sarton E; Teppema L; Berkenbosch A; Dahan A Br J Anaesth; 1998 Feb; 80(2):174-82. PubMed ID: 9602581 [TBL] [Abstract][Full Text] [Related]
19. Wash-in kinetics for sevoflurane using a disposable delivery system (AnaConDa) in cardiac surgery patients. Sturesson LW; Johansson A; Bodelsson M; Malmkvist G Br J Anaesth; 2009 Apr; 102(4):470-6. PubMed ID: 19244261 [TBL] [Abstract][Full Text] [Related]
20. Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice. Marcos-Vidal JM; Merino M; González R; García C; Rey S; Pérez I J Clin Monit Comput; 2020 Feb; 34(1):89-95. PubMed ID: 30784010 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]