These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 19189222)

  • 1. Technical performance and reflection capacity of the anaesthetic conserving device--a bench study with isoflurane and sevoflurane.
    Meiser A; Bellgardt M; Belda J; Röhm K; Laubenthal H; Sirtl C
    J Clin Monit Comput; 2009 Feb; 23(1):11-9. PubMed ID: 19189222
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reflection efficiencies of AnaConDa-S and AnaConDa-100 for isoflurane under dry laboratory and simulated clinical conditions: a bench study using a test lung.
    Kermad A; Speltz J; Daume P; Volk T; Meiser A
    Expert Rev Med Devices; 2021 Feb; 18(2):189-195. PubMed ID: 33322972
    [No Abstract]   [Full Text] [Related]  

  • 3. [Functioning of the anaesthetic conserving device: aspects to consider for use in inhalational sedation].
    Meiser A; Bellgardt M; Vogelsang H; Sirtl C; Weber T
    Anaesthesist; 2010 Nov; 59(11):1029-40. PubMed ID: 20878139
    [TBL] [Abstract][Full Text] [Related]  

  • 4. AnaConDa reflection filter: bench and patient evaluation of safety and volatile anesthetic conservation.
    Berton J; Sargentini C; Nguyen JL; Belii A; Beydon L
    Anesth Analg; 2007 Jan; 104(1):130-4. PubMed ID: 17179257
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model.
    Bomberg H; Meiser F; Daume P; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A
    Anesth Analg; 2019 Aug; 129(2):371-379. PubMed ID: 29787413
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care.
    Farrell R; Oomen G; Carey P
    J Clin Monit Comput; 2018 Aug; 32(4):595-604. PubMed ID: 29388094
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilation.
    Sturesson LW; Bodelsson M; Jonson B; Malmkvist G
    Br J Anaesth; 2014 Sep; 113(3):508-14. PubMed ID: 24871871
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Halving the volume of AnaConDa: initial clinical experience with a new small-volume anaesthetic reflector in critically ill patients-a quality improvement project.
    Bomberg H; Meiser F; Zimmer S; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A
    J Clin Monit Comput; 2018 Aug; 32(4):639-646. PubMed ID: 29700664
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sevoflurane output from the Oxford Miniature Vaporizer in drawover mode.
    Liu EH; Dhara SS
    Anaesth Intensive Care; 2000 Oct; 28(5):532-6. PubMed ID: 11094669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Uncontrolled delivery of liquid volatile anaesthetic when using the anaesthetic conserving device.
    Karnjuš I; Mekiš D; Križmarić M
    J Clin Monit Comput; 2018 Aug; 32(4):629-638. PubMed ID: 28567612
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A pharmacokinetic study of 48-hour sevoflurane inhalation using a disposable delivery system (AnaConDa®) in ICU patients.
    Perbet S; Bourdeaux D; Sautou V; Pereira B; Chabanne R; Constantin JM; Chopineau J; Bazin JE
    Minerva Anestesiol; 2014 Jun; 80(6):655-65. PubMed ID: 24226486
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Increasing the reflection efficiency of the Sedaconda ACD-S by heating and cooling the anaesthetic reflector: a bench study using a test lung.
    Meiser A; Meis PLF; O'Gara B; Volk T; Kermad A
    J Clin Monit Comput; 2023 Jun; 37(3):919-924. PubMed ID: 36625981
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical ventilation of six dogs anaesthetised with isoflurane or sevoflurane delivered by a Komesaroff anaesthetic machine.
    Laredo FG; Belda E; Escobar M
    Vet Rec; 2009 Jun; 164(24):751-4. PubMed ID: 19525524
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Low flow anaesthesia with isoflurane and sevoflurane in the dog].
    Kramer S; Alyakine H; Nolte I
    Berl Munch Tierarztl Wochenschr; 2008; 121(1-2):53-65. PubMed ID: 18277780
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preparation of Datex-Ohmeda Aestiva and Aisys anaesthetic machines for use in malignant hyperthermia susceptible patients.
    Jones C; Bennett K; Kim TW; Bulger TF; Pollock N
    Anaesth Intensive Care; 2012 May; 40(3):490-7. PubMed ID: 22577915
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sevoflurane Output in the Isoflurane/Halothane Diamedica Draw-over Vaporiser.
    Tay WC; Tan WT
    Ann Acad Med Singap; 2015 Jul; 44(7):252-6. PubMed ID: 26377059
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Reflector: a new method for saving anaesthetic vapours.
    Perhag L; Reinstrup P; Thomasson R; Werner O
    Br J Anaesth; 2000 Sep; 85(3):482-6. PubMed ID: 11103198
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of 0.1 minimum alveolar concentration of sevoflurane, desflurane and isoflurane on dynamic ventilatory response to hypercapnia in humans.
    van den Elsen M; Sarton E; Teppema L; Berkenbosch A; Dahan A
    Br J Anaesth; 1998 Feb; 80(2):174-82. PubMed ID: 9602581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wash-in kinetics for sevoflurane using a disposable delivery system (AnaConDa) in cardiac surgery patients.
    Sturesson LW; Johansson A; Bodelsson M; Malmkvist G
    Br J Anaesth; 2009 Apr; 102(4):470-6. PubMed ID: 19244261
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the use of AnaConDa® versus AnaConDa-S® during the post-operative period of cardiac surgery under standard conditions of practice.
    Marcos-Vidal JM; Merino M; González R; García C; Rey S; Pérez I
    J Clin Monit Comput; 2020 Feb; 34(1):89-95. PubMed ID: 30784010
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.