BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 19190360)

  • 1. A high-sensitivity small animal SPECT system.
    Mitchell GS; Cherry SR
    Phys Med Biol; 2009 Mar; 54(5):1291-305. PubMed ID: 19190360
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging.
    Walker KL; Judenhofer MS; Cherry SR; Mitchell GS
    Phys Med Biol; 2015 Jan; 60(1):403-20. PubMed ID: 25504038
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector.
    Ogawa K; Ohmura N; Iida H; Nakamura K; Nakahara T; Kubo A
    Ann Nucl Med; 2009 Oct; 23(8):763-70. PubMed ID: 19680739
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design and simulation of a high-resolution stationary SPECT system for small animals.
    Beekman FJ; Vastenhouw B
    Phys Med Biol; 2004 Oct; 49(19):4579-92. PubMed ID: 15552418
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultra-high-sensitivity submillimeter mouse SPECT.
    Ivashchenko O; van der Have F; Goorden MC; Ramakers RM; Beekman FJ
    J Nucl Med; 2015 Mar; 56(3):470-5. PubMed ID: 25678487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging.
    Janssen JP; Hoffmann JV; Kanno T; Nose N; Grunz JP; Onoguchi M; Chen X; Lapa C; Buck AK; Higuchi T
    Sci Rep; 2020 Oct; 10(1):18616. PubMed ID: 33122774
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A multipinhole small animal SPECT system with submillimeter spatial resolution.
    Funk T; Després P; Barber WC; Shah KS; Hasegawa BH
    Med Phys; 2006 May; 33(5):1259-68. PubMed ID: 16752560
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Appropriate collimators in a small animal SPECT scanner with CZT detector.
    Higaki Y; Kobayashi M; Uehara T; Hanaoka H; Arano Y; Kawai K
    Ann Nucl Med; 2013 Apr; 27(3):271-8. PubMed ID: 23288435
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simulation study of a novel target oriented SPECT design using a variable pinhole collimator.
    Bae S; Chun J; Cha H; Yeom JY; Lee K; Lee H
    Med Phys; 2017 Feb; 44(2):470-478. PubMed ID: 28032904
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging.
    Mejia J; Galvis-Alonso OY; Castro AA; Braga J; Leite JP; Simões MV
    Braz J Med Biol Res; 2010 Dec; 43(12):1160-6. PubMed ID: 21085887
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Monte Carlo study on the performance evaluation of a parallel hole collimator for a HiReSPECT: A dedicated small-animal SPECT.
    Abbaspour S; Tanha K; Mahmoudian B; Assadi M; Pirayesh Islamian J
    Appl Radiat Isot; 2018 Sep; 139():53-60. PubMed ID: 29704706
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultra-high resolution SPECT system using four pinhole collimators for small animal studies.
    Ishizu K; Mukai T; Yonekura Y; Pagani M; Fujita T; Magata Y; Nishizawa S; Tamaki N; Shibasaki H; Konishi J
    J Nucl Med; 1995 Dec; 36(12):2282-7. PubMed ID: 8523120
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance evaluation of the eXplore speCZT preclinical imaging system.
    Matsunari I; Miyazaki Y; Kobayashi M; Nishi K; Mizutani A; Kawai K; Hayashi A; Komatsu R; Yonezawa S; Kinuya S
    Ann Nucl Med; 2014 Jun; 28(5):484-97. PubMed ID: 24610679
    [TBL] [Abstract][Full Text] [Related]  

  • 14. U-SPECT-II: An Ultra-High-Resolution Device for Molecular Small-Animal Imaging.
    van der Have F; Vastenhouw B; Ramakers RM; Branderhorst W; Krah JO; Ji C; Staelens SG; Beekman FJ
    J Nucl Med; 2009 Apr; 50(4):599-605. PubMed ID: 19289425
    [TBL] [Abstract][Full Text] [Related]  

  • 15. VECTor: a preclinical imaging system for simultaneous submillimeter SPECT and PET.
    Goorden MC; van der Have F; Kreuger R; Ramakers RM; Vastenhouw B; Burbach JP; Booij J; Molthoff CF; Beekman FJ
    J Nucl Med; 2013 Feb; 54(2):306-12. PubMed ID: 23077113
    [TBL] [Abstract][Full Text] [Related]  

  • 16. U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice.
    Beekman FJ; van der Have F; Vastenhouw B; van der Linden AJ; van Rijk PP; Burbach JP; Smidt MP
    J Nucl Med; 2005 Jul; 46(7):1194-200. PubMed ID: 16000289
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quarter-millimeter-resolution molecular mouse imaging with U-SPECT⁺.
    Ivashchenko O; van der Have F; Villena JL; Groen HC; Ramakers RM; Weinans HH; Beekman FJ
    Mol Imaging; 2014; 13():. PubMed ID: 25429783
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT.
    Jaszczak RJ; Li J; Wang H; Zalutsky MR; Coleman RE
    Phys Med Biol; 1994 Mar; 39(3):425-37. PubMed ID: 15551591
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.
    Van Audenhaege K; Van Holen R; Vandenberghe S; Vanhove C; Metzler SD; Moore SC
    Med Phys; 2015 Aug; 42(8):4796-813. PubMed ID: 26233207
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.
    Kobayashi M; Matsunari I; Nishi K; Mizutani A; Miyazaki Y; Ogai K; Sugama J; Shiba K; Kawai K; Kinuya S
    Ann Nucl Med; 2016 May; 30(4):263-71. PubMed ID: 26747655
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.