182 related articles for article (PubMed ID: 19193375)
1. The dynamic locking blade plate, a new implant for intracapsular hip fractures: biomechanical comparison with the sliding hip screw and Twin Hook.
Roerdink WH; Aalsma AM; Nijenbanning G; van Walsum AD
Injury; 2009 Mar; 40(3):283-7. PubMed ID: 19193375
[TBL] [Abstract][Full Text] [Related]
2. Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.
Olsson O
Acta Orthop Scand Suppl; 2000 Oct; 295():1-31. PubMed ID: 11116961
[TBL] [Abstract][Full Text] [Related]
3. Biomechanical analysis of the percutaneous compression plate and sliding hip screw in intracapsular hip fractures: experimental assessment using synthetic and cadaver bones.
Brandt E; Verdonschot N; van Vugt A; van Kampen A
Injury; 2006 Oct; 37(10):979-83. PubMed ID: 16934259
[TBL] [Abstract][Full Text] [Related]
4. Initial promising results of the dynamic locking blade plate, a new implant for the fixation of intracapsular hip fractures: results of a pilot study.
Roerdink WH; Aalsma AM; Nijenbanning G; van Walsum AD
Arch Orthop Trauma Surg; 2011 Apr; 131(4):519-24. PubMed ID: 20963430
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw.
Al-Munajjed AA; Hammer J; Mayr E; Nerlich M; Lenich A
Stud Health Technol Inform; 2008; 133():1-10. PubMed ID: 18376008
[TBL] [Abstract][Full Text] [Related]
6. Dynamic hip screw versus DHS blade: a biomechanical comparison of the fixation achieved by each implant in bone.
O'Neill F; Condon F; McGloughlin T; Lenehan B; Coffey JC; Walsh M
J Bone Joint Surg Br; 2011 May; 93(5):616-21. PubMed ID: 21511926
[TBL] [Abstract][Full Text] [Related]
7. Locking plates increase the strength of dynamic hip screws.
Jewell DP; Gheduzzi S; Mitchell MS; Miles AW
Injury; 2008 Feb; 39(2):209-12. PubMed ID: 17880976
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures.
Floyd JC; O'Toole RV; Stall A; Forward DP; Nabili M; Shillingburg D; Hsieh A; Nascone JW
J Orthop Trauma; 2009 Oct; 23(9):628-33. PubMed ID: 19897983
[TBL] [Abstract][Full Text] [Related]
10. Rotationally stable screw-anchor versus sliding hip screw plate systems in stable trochanteric femur fractures: a biomechanical evaluation.
Knobe M; Gradl G; Maier KJ; Drescher W; Jansen-Troy A; Prescher A; Knechtel T; Antony P; Pape HC
J Orthop Trauma; 2013 Jun; 27(6):e127-36. PubMed ID: 23114419
[TBL] [Abstract][Full Text] [Related]
11. Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation.
Windolf M; Braunstein V; Dutoit C; Schwieger K
Clin Biomech (Bristol, Avon); 2009 Jan; 24(1):59-64. PubMed ID: 18977058
[TBL] [Abstract][Full Text] [Related]
12. A biomechanical study on fixation stability with twin hook or lag screw in artificial cancellous bone.
Olsson O; Tanner KE; Ceder L; Ryd L
Int Orthop; 2002; 26(6):349-55. PubMed ID: 12466867
[TBL] [Abstract][Full Text] [Related]
13. [Hansson Twin Hook--a new implant technique in trochanteric fractures].
Alexa O; Cozma T; Cionca D; Puha B
Rev Med Chir Soc Med Nat Iasi; 2006; 110(1):161-6. PubMed ID: 19292098
[TBL] [Abstract][Full Text] [Related]
14. [Fracture of the great trochanter treated by dynamic hip screw plate: measure of impaction according to fracture type].
Oger P; Katz V; Lecorre N; Beaufils P
Rev Chir Orthop Reparatrice Appar Mot; 1998 Oct; 84(6):539-45. PubMed ID: 9846328
[TBL] [Abstract][Full Text] [Related]
15. Does cancellous bone compaction due to insertion of a blade implant influence the cut-out resistance? A biomechanical study.
Wähnert D; Gudushauri P; Schiuma D; Richards G; Windolf M
Clin Biomech (Bristol, Avon); 2010 Dec; 25(10):1053-7. PubMed ID: 20800326
[TBL] [Abstract][Full Text] [Related]
16. Basicervical fractures of the proximal femur. A biomechanical study of 3 internal fixation techniques.
Blair B; Koval KJ; Kummer F; Zuckerman JD
Clin Orthop Relat Res; 1994 Sep; (306):256-63. PubMed ID: 8070205
[TBL] [Abstract][Full Text] [Related]
17. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.
Crist BD; Khalafi A; Hazelwood SJ; Lee MA
J Orthop Trauma; 2009 Oct; 23(9):622-7. PubMed ID: 19897982
[TBL] [Abstract][Full Text] [Related]
18. Correct placement of the screw or nail in trochanteric fractures. Effect of the initial placement in the migration.
Galanakis IA; Steriopoulos KA; Dretakis EK
Clin Orthop Relat Res; 1995 Apr; (313):206-13. PubMed ID: 7641482
[TBL] [Abstract][Full Text] [Related]
19. A short plate compression screw with diagonal bolts--a biomechanical evaluation performed experimentally and by numerical computation.
Peleg E; Mosheiff R; Liebergall M; Mattan Y
Clin Biomech (Bristol, Avon); 2006 Nov; 21(9):963-8. PubMed ID: 16893595
[TBL] [Abstract][Full Text] [Related]
20. Minimally invasive screw plates for surgery of unstable intertrochanteric femoral fractures: a biomechanical comparative study.
Ropars M; Mitton D; Skalli W
Clin Biomech (Bristol, Avon); 2008 Oct; 23(8):1012-7. PubMed ID: 18579266
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]