These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 19203745)

  • 1. Evaluation of myocardial viability by multidetector CT.
    Mendoza DD; Weigold WG
    J Cardiovasc Comput Tomogr; 2009; 3(1 Suppl):S2-12. PubMed ID: 19203745
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comprehensive cardiac CT study: evaluation of coronary arteries, left ventricular function, and myocardial perfusion--is it possible?
    Cury RC; Nieman K; Shapiro MD; Nasir K; Cury RC; Brady TJ
    J Nucl Cardiol; 2007 Apr; 14(2):229-43. PubMed ID: 17386386
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Changing paradigm: atherosclerosis versus ischaemia.
    Schuijf JD; van der Wall EE; Bax JJ
    Eur J Nucl Med Mol Imaging; 2007 Jan; 34(1):1-3. PubMed ID: 16951955
    [No Abstract]   [Full Text] [Related]  

  • 4. Measurement of left ventricular volume and ejection fraction with computed tomography: Small steps toward clinical utility.
    Halliburton SS
    J Cardiovasc Comput Tomogr; 2008; 2(4):231-3. PubMed ID: 19083955
    [No Abstract]   [Full Text] [Related]  

  • 5. Efficacy of coronary CT angiography: where we are, where we are going, and where we want to be.
    Levsky JM; Kim CW; Spevack DM; Travin MI; Tobin JN; Haramati LB
    J Cardiovasc Comput Tomogr; 2009; 3 Suppl 2():S99-108. PubMed ID: 20129523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Identification of severe left main trunk coronary stenosis on MDCT coronary angiography.
    Hayek ER; White HA; Kamienski RW
    AJR Am J Roentgenol; 2007 Jan; 188(1):W93. PubMed ID: 17179334
    [No Abstract]   [Full Text] [Related]  

  • 7. Multidetector computed tomography evaluation of left ventricular volumes: sources of error and guidelines for their minimization.
    Bardo DM; Kachenoura N; Newby B; Lang RM; Mor-Avi V
    J Cardiovasc Comput Tomogr; 2008; 2(4):222-30. PubMed ID: 19083954
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Integrative computed tomographic imaging of coronary artery disease.
    Weininger M; Renker M; Rowe GW; Abro JA; Costello P; Schoepf UJ
    Expert Rev Cardiovasc Ther; 2011 Jan; 9(1):27-43. PubMed ID: 21166527
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative assessment of left ventricular systolic wall thickening using multidetector computed tomography.
    Kristensen TS; Kofoed KF; Møller DV; Ersbøll M; Kühl T; von der Recke P; Køber L; Nielsen MB; Kelbaek H
    Eur J Radiol; 2009 Oct; 72(1):92-7. PubMed ID: 18687544
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coronary CT angiography without beta-blockers.
    Colletti PM
    AJR Am J Roentgenol; 2007 Dec; 189(6):1324-5. PubMed ID: 18029866
    [No Abstract]   [Full Text] [Related]  

  • 11. Comparison of manual, semi- and fully automated heart segmentation for assessing global left ventricular function in multidetector computed tomography.
    Plumhans C; Keil S; Ocklenburg C; Mühlenbruch G; Behrendt FF; Günther RW; Mahnken AH
    Invest Radiol; 2009 Aug; 44(8):476-82. PubMed ID: 19561515
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimizing coronary artery imaging in patients with atrial fibrillation with ECG-gated 64-MDCT.
    Strub WM; Vagal A; Meyer C
    AJR Am J Roentgenol; 2007 Jul; 189(1):W50-1. PubMed ID: 17579139
    [No Abstract]   [Full Text] [Related]  

  • 13. Identifying and redefining stenosis by CT angiography.
    Kochar M; Arsanjani R; Raman SV; Shaw LJ; Berman DS; Min JK
    Cardiol Clin; 2012 Feb; 30(1):57-67. PubMed ID: 22304949
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of acute reperfused myocardial infarction with delayed enhancement 64-MDCT.
    Baks T; Cademartiri F; Moelker AD; van der Giessen WJ; Krestin GP; Duncker DJ; de Feyter PJ
    AJR Am J Roentgenol; 2007 Feb; 188(2):W135-7. PubMed ID: 17242218
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of spiral multidetector CT angiography and myocardial perfusion imaging in the noninvasive detection of functionally relevant coronary artery lesions: first clinical experiences.
    Hacker M; Jakobs T; Matthiesen F; Vollmar C; Nikolaou K; Becker C; Knez A; Pfluger T; Reiser M; Hahn K; Tiling R
    J Nucl Med; 2005 Aug; 46(8):1294-300. PubMed ID: 16085585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multidetector CT coronary angiography: have we found the holy grail of non-invasive coronary imaging?
    Donnelly PM; Higginson JD; Hanley PD
    Heart; 2005 Nov; 91(11):1385-8. PubMed ID: 16230434
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Coronary artery CTA: imaging of atherosclerosis in the coronary arteries and reporting of coronary artery CTA findings.
    Zimmet JM; Miller JM
    Tech Vasc Interv Radiol; 2006 Dec; 9(4):218-26. PubMed ID: 17709087
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The present and future of cardiac CT in research and clinical practice: moderated discussion and scientific debate with representatives from the four main vendors.
    Dewey M; de Vries H; de Vries L; Haas D; Leidecker C
    Rofo; 2010 Apr; 182(4):313-21. PubMed ID: 20234975
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT.
    Seifarth H; Wienbeck S; Püsken M; Juergens KU; Maintz D; Vahlhaus C; Heindel W; Fischbach R
    AJR Am J Roentgenol; 2007 Dec; 189(6):1317-23. PubMed ID: 18029865
    [TBL] [Abstract][Full Text] [Related]  

  • 20. How image quality can be improved: our experience with multidetector computed tomography coronary angiography.
    Ozturk E; Kantarci M; Durur-Subasi I; Bayraktutan U; Karaman A; Bayram E; Ogul H; Ceviz N
    Clin Imaging; 2007; 31(1):11-7. PubMed ID: 17189840
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.