BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 19205075)

  • 1. Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy.
    Rata M; Salomir R; Umathum R; Jenne J; Lafon C; Cotton F; Bock M
    Phys Med Biol; 2008 Nov; 53(22):6549-67. PubMed ID: 19205075
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoluminal MR-guided ultrasonic applicator embedding cylindrical phased-array transducers and opposed-solenoid detection coil.
    Rata M; Birlea V; Murillo A; Paquet C; Cotton F; Salomir R
    Magn Reson Med; 2015 Jan; 73(1):417-26. PubMed ID: 24478117
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endocavitary thermal therapy by MRI-guided phased-array contact ultrasound: experimental and numerical studies on the multi-input single-output PID temperature controller's convergence and stability.
    Salomir R; Rata M; Cadis D; Petrusca L; Auboiroux V; Cotton F
    Med Phys; 2009 Oct; 36(10):4726-41. PubMed ID: 19928104
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
    Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
    Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model.
    Adams MS; Salgaonkar VA; Plata-Camargo J; Jones PD; Pascal-Tenorio A; Chen HY; Bouley DM; Sommer G; Pauly KB; Diederich CJ
    Med Phys; 2016 Jul; 43(7):4184. PubMed ID: 27370138
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transrectal ultrasound applicator for prostate heating monitored using MRI thermometry.
    Smith NB; Buchanan MT; Hynynen K
    Int J Radiat Oncol Biol Phys; 1999 Jan; 43(1):217-25. PubMed ID: 9989529
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High intensity focused ultrasound induced in vivo large volume hyperthermia under 3D MRI temperature control.
    Tillander M; Hokland S; Koskela J; Dam H; Andersen NP; Pedersen M; Tanderup K; Ylihautala M; Köhler M
    Med Phys; 2016 Mar; 43(3):1539-49. PubMed ID: 26936737
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
    Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
    Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and development of a prototype endocavitary probe for high-intensity focused ultrasound delivery with integrated magnetic resonance imaging.
    Wharton IP; Rivens IH; Ter Haar GR; Gilderdale DJ; Collins DJ; Hand JW; Abel PD; deSouza NM
    J Magn Reson Imaging; 2007 Mar; 25(3):548-56. PubMed ID: 17279503
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array.
    Payne A; Merrill R; Minalga E; Vyas U; de Bever J; Todd N; Hadley R; Dumont E; Neumayer L; Christensen D; Roemer R; Parker D
    Med Phys; 2012 Mar; 39(3):1552-60. PubMed ID: 22380387
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Active MR-temperature feedback control of dynamic interstitial ultrasound therapy in brain: in vivo experiments and modeling in native and coagulated tissues.
    N'Djin WA; Burtnyk M; Lipsman N; Bronskill M; Kucharczyk W; Schwartz ML; Chopra R
    Med Phys; 2014 Sep; 41(9):093301. PubMed ID: 25186419
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MR guided thermal therapy of pancreatic tumors with endoluminal, intraluminal and interstitial catheter-based ultrasound devices: Preliminary theoretical and experimental investigations.
    Prakash P; Salgaonkar VA; Scott SJ; Jones P; Hensley D; Holbrook A; Plata J; Sommer G; Diederich CJ
    Proc SPIE Int Soc Opt Eng; 2013 Feb; 8584():85840V. PubMed ID: 24860246
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraluminal ultrasound applicator compatible with magnetic resonance imaging "real-time" temperature mapping for the treatment of oesophageal tumours: an ex vivo study.
    Melodelima D; Salomir R; Mougenot C; Prat F; Theillère Y; Moonen C; Cathignol D
    Med Phys; 2004 Feb; 31(2):236-44. PubMed ID: 15000609
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automatic temperature control for MR-guided interstitial ultrasound ablation in liver using a percutaneous applicator: ex vivo and in vivo initial studies.
    Delabrousse E; Salomir R; Birer A; Paquet C; Mithieux F; Chapelon JY; Cotton F; Lafon C
    Magn Reson Med; 2010 Mar; 63(3):667-79. PubMed ID: 20187177
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thermal magnetic resonance: physics considerations and electromagnetic field simulations up to 23.5 Tesla (1GHz).
    Winter L; Oezerdem C; Hoffmann W; van de Lindt T; Periquito J; Ji Y; Ghadjar P; Budach V; Wust P; Niendorf T
    Radiat Oncol; 2015 Sep; 10():201. PubMed ID: 26391138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integrated endoscope for real-time 3D ultrasound imaging and hyperthermia: feasibility study.
    Pua EC; Qiu Y; Smith SW
    Ultrason Imaging; 2007 Jan; 29(1):1-14. PubMed ID: 17491295
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of an endoluminal high-intensity ultrasound applicator for image-guided thermal therapy of pancreatic tumors.
    Adams MS; Scott SJ; Salgaonkar VA; Jones PD; Plata-Camargo JC; Sommer G; Diederich CJ
    Proc SPIE Int Soc Opt Eng; 2015 Feb; 9326():. PubMed ID: 26677314
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual-Function MR-Guided Hyperthermia: An Innovative Integrated Approach and Experimental Demonstration of Proof of Principle.
    Sumser K; Bellizzi GG; Forner R; Drizdal T; Tamames JAH; van Rhoon GC; Paulides MM
    IEEE Trans Biomed Eng; 2021 Feb; 68(2):712-717. PubMed ID: 32746075
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of custom RF coils for use in a small animal platform for magnetic resonance-guided focused ultrasound hyperthermia compatible with a clinical MRI scanner.
    Abraham CB; Loree-Spacek J; Andrew Drainville R; Pichardo S; Curiel L
    Int J Hyperthermia; 2018; 35(1):348-360. PubMed ID: 30295125
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Non-invasive thermometry using magnetic resonance diffusion imaging: potential for application in hyperthermic oncology.
    Samulski TV; MacFall J; Zhang Y; Grant W; Charles C
    Int J Hyperthermia; 1992; 8(6):819-29. PubMed ID: 1479207
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.