These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
189 related articles for article (PubMed ID: 19212236)
1. In vivo changes in dental implant temperatures during hot beverage intake: a pilot study. Ormianer Z; Feuerstein O; Assad R; Samet N; Weiss EI Implant Dent; 2009 Feb; 18(1):38-45. PubMed ID: 19212236 [TBL] [Abstract][Full Text] [Related]
2. Temperature changes in dental implants following exposure to hot substances in an ex vivo model. Feuerstein O; Zeichner K; Imbari C; Ormianer Z; Samet N; Weiss EI Clin Oral Implants Res; 2008 Jun; 19(6):629-33. PubMed ID: 18371098 [TBL] [Abstract][Full Text] [Related]
3. Heat transfer to the implant-bone interface during preparation of a zirconia/alumina abutment. Huh JB; Eckert SE; Ko SM; Choi YG Int J Oral Maxillofac Implants; 2009; 24(4):679-83. PubMed ID: 19885408 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of heat conduction in dental implants after exposure to hot beverages. Livne S; Harel N; Piek D; Ormianer Z J Prosthet Dent; 2014 Mar; 111(3):228-33. PubMed ID: 24262947 [TBL] [Abstract][Full Text] [Related]
5. An investigation of heat transfer to the implant-bone interface related to exothermic heat generation during setting of autopolymerizing acrylic resins applied directly to an implant abutment. Ormianer Z; Laufer BZ; Nissan J; Gross M Int J Oral Maxillofac Implants; 2000; 15(6):837-42. PubMed ID: 11151583 [TBL] [Abstract][Full Text] [Related]
6. An investigation on heat transfer to the implant-bone interface due to abutment preparation with high-speed cutting instruments. Gross M; Laufer BZ; Ormianar Z Int J Oral Maxillofac Implants; 1995; 10(2):207-12. PubMed ID: 7744440 [TBL] [Abstract][Full Text] [Related]
7. Temperature changes at the implant-bone interface during simulated surface decontamination with an Er:YAG laser. Kreisler M; Al Haj H; d'Hoedt B Int J Prosthodont; 2002; 15(6):582-7. PubMed ID: 12475166 [TBL] [Abstract][Full Text] [Related]
8. Heat transfer of impression plasters to an implant-bone interface. Nissan J; Gross M; Ormianer Z; Barnea E; Assif D Implant Dent; 2006 Mar; 15(1):83-8. PubMed ID: 16569966 [TBL] [Abstract][Full Text] [Related]
9. Wear at the titanium-zirconia implant-abutment interface: a pilot study. Klotz MW; Taylor TD; Goldberg AJ Int J Oral Maxillofac Implants; 2011; 26(5):970-5. PubMed ID: 22010078 [TBL] [Abstract][Full Text] [Related]
10. Biofilm on dental implants: a review of the literature. Subramani K; Jung RE; Molenberg A; Hammerle CH Int J Oral Maxillofac Implants; 2009; 24(4):616-26. PubMed ID: 19885401 [TBL] [Abstract][Full Text] [Related]
11. Temperature changes along a dental implant. Patel Z; Geerts GA Int J Prosthodont; 2011; 24(1):58-63. PubMed ID: 21210006 [TBL] [Abstract][Full Text] [Related]
12. Acrylic resin polymerization in direct contact to the abutment and the temperature at bone-implant interface: a pilot in vitro study. Kazemi M; Jalali H; Eghtedari M; Sadrimanesh R; Sadr-Eshkevari P; Maurer P J Oral Implantol; 2012 Oct; 38(5):595-601. PubMed ID: 20932123 [TBL] [Abstract][Full Text] [Related]
13. A 24-week prospective study comparing the stability of titanium dioxide grit-blasted dental implants with and without fluoride treatment. Geckili O; Bilhan H; Bilgin T Int J Oral Maxillofac Implants; 2009; 24(4):684-8. PubMed ID: 19885409 [TBL] [Abstract][Full Text] [Related]
14. A classification system to measure the implant-abutment microgap. Kano SC; Binon PP; Curtis DA Int J Oral Maxillofac Implants; 2007; 22(6):879-85. PubMed ID: 18271368 [TBL] [Abstract][Full Text] [Related]
16. Load fatigue performance of implant-ceramic abutment combinations. Nguyen HQ; Tan KB; Nicholls JI Int J Oral Maxillofac Implants; 2009; 24(4):636-46. PubMed ID: 19885403 [TBL] [Abstract][Full Text] [Related]
17. Resistance to dislodgement of zirconia copings cemented onto titanium abutments of different heights. Abbo B; Razzoog ME; Vivas J; Sierraalta M J Prosthet Dent; 2008 Jan; 99(1):25-9. PubMed ID: 18182182 [TBL] [Abstract][Full Text] [Related]
18. Implant abutment deformation during prosthetic cylinder screw tightening: an in vitro study. Neto RT; Moura MS; Souza EA; Rubo JH Int J Prosthodont; 2009; 22(4):391-5. PubMed ID: 19639078 [TBL] [Abstract][Full Text] [Related]
19. Influence of the height of the external hexagon and surface treatment on fatigue life of commercially pure titanium dental implants. Gil FJ; Aparicio C; Manero JM; Padros A Int J Oral Maxillofac Implants; 2009; 24(4):583-90. PubMed ID: 19885397 [TBL] [Abstract][Full Text] [Related]
20. Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals. Al-Keraidis A; Aleisa K; Al-Dwairi ZN; Al-Tahawi H; Hsu ML; Lynch E; Özcan M Implant Dent; 2017 Oct; 26(5):700-705. PubMed ID: 28475499 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]