BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

581 related articles for article (PubMed ID: 19214094)

  • 1. Prophylactic vertebroplasty may reduce the risk of adjacent intact vertebra from fatigue injury: an ex vivo biomechanical study.
    Chiang CK; Wang YH; Yang CY; Yang BD; Wang JL
    Spine (Phila Pa 1976); 2009 Feb; 34(4):356-64. PubMed ID: 19214094
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility study of using viscoplastic bone cement for vertebroplasty: an in vivo clinical trial and in vitro cadaveric biomechanical examination.
    Lin SW; Chiang CK; Yang CL; Wang JL
    Spine (Phila Pa 1976); 2010 May; 35(10):E385-91. PubMed ID: 20393389
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical changes after the augmentation of experimental osteoporotic vertebral compression fractures in the cadaveric thoracic spine.
    Kayanja MM; Togawa D; Lieberman IH
    Spine J; 2005; 5(1):55-63. PubMed ID: 15653085
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A biomechanical investigation of vertebroplasty in osteoporotic compression fractures and in prophylactic vertebral reinforcement.
    Furtado N; Oakland RJ; Wilcox RK; Hall RM
    Spine (Phila Pa 1976); 2007 Aug; 32(17):E480-7. PubMed ID: 17762281
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preliminary biomechanical evaluation of prophylactic vertebral reinforcement adjacent to vertebroplasty under cyclic loading.
    Oakland RJ; Furtado NR; Wilcox RK; Timothy J; Hall RM
    Spine J; 2009 Feb; 9(2):174-81. PubMed ID: 18640876
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evolution of bone mineral density after percutaneous kyphoplasty in fresh osteoporotic vertebral body fractures and adjacent vertebrae along with sagittal spine alignment.
    Korovessis P; Zacharatos S; Repantis T; Michael A; Karachalios D
    J Spinal Disord Tech; 2008 Jun; 21(4):293-8. PubMed ID: 18525491
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Restoring geometric and loading alignment of the thoracic spine with a vertebral compression fracture: effects of balloon (bone tamp) inflation and spinal extension.
    Gaitanis IN; Carandang G; Phillips FM; Magovern B; Ghanayem AJ; Voronov LI; Havey RM; Zindrick MR; Hadjipavlou AG; Patwardhan AG
    Spine J; 2005; 5(1):45-54. PubMed ID: 15653084
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adjacent vertebral body fracture following vertebroplasty with polymethylmethacrylate or calcium phosphate cement: biomechanical evaluation of the cadaveric spine.
    Nouda S; Tomita S; Kin A; Kawahara K; Kinoshita M
    Spine (Phila Pa 1976); 2009 Nov; 34(24):2613-8. PubMed ID: 19910764
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanism of fractures of adjacent and augmented vertebrae following simulated vertebroplasty.
    Wang JL; Chiang CK; Kuo YW; Chou WK; Yang BD
    J Biomech; 2012 May; 45(8):1372-8. PubMed ID: 22444349
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical evaluation of calcium phosphate-based nanocomposite versus polymethylmethacrylate cement for percutaneous kyphoplasty.
    Lu Q; Liu C; Wang D; Liu H; Yang H; Yang L
    Spine J; 2019 Nov; 19(11):1871-1884. PubMed ID: 31202837
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prophylactic vertebroplasty can decrease the fracture risk of adjacent vertebrae: an in vitro cadaveric study.
    Aquarius R; Homminga J; Hosman AJ; Verdonschot N; Tanck E
    Med Eng Phys; 2014 Jul; 36(7):944-8. PubMed ID: 24736018
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adjacent-level symptomatic fracture after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a retrospective analysis.
    Wang YT; Wu XT; Chen H; Wang C; Mao ZB
    J Orthop Sci; 2014 Nov; 19(6):868-76. PubMed ID: 25092145
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative biomechanical study of a new transpedicular vertebral device and vertebroplasty for the treatment or prevention of vertebral compression fractures.
    Aebi M; Maas C; Di Pauli von Treuheim T; Friedrich H; Wilke HJ
    Clin Biomech (Bristol, Avon); 2018 Jul; 56():40-45. PubMed ID: 29803111
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling.
    Peng Y; Du X; Huang L; Li J; Zhan R; Wang W; Xu B; Wu S; Peng C; Chen S
    Med Biol Eng Comput; 2018 Nov; 56(11):2137-2150. PubMed ID: 29806053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vertebroplasty with high-viscosity polymethylmethacrylate cement facilitates vertebral body restoration in vitro.
    Rüger M; Schmoelz W
    Spine (Phila Pa 1976); 2009 Nov; 34(24):2619-25. PubMed ID: 19881400
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Percutaneous vertebral augmentation: an elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty.
    Frankel BM; Monroe T; Wang C
    Spine J; 2007; 7(5):575-82. PubMed ID: 17905320
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Vertebral augmentation with a novel Vessel-X bone void filling container system and bioactive bone cement.
    Zheng Z; Luk KD; Kuang G; Li Z; Lin J; Lam WM; Cheung KM; Lu WW
    Spine (Phila Pa 1976); 2007 Sep; 32(19):2076-82. PubMed ID: 17762808
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of vertebroplasty on endplate subsidence in elderly female spines.
    Nagaraja S; Awada HK; Dreher ML; Bouck JT; Gupta S
    J Neurosurg Spine; 2015 Mar; 22(3):273-82. PubMed ID: 25525963
    [TBL] [Abstract][Full Text] [Related]  

  • 19. How are adjacent spinal levels affected by vertebral fracture and by vertebroplasty? A biomechanical study on cadaveric spines.
    Luo J; Annesley-Williams DJ; Adams MA; Dolan P
    Spine J; 2017 Jun; 17(6):863-874. PubMed ID: 28167249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical performance of the new BeadEx implant in the treatment of osteoporotic vertebral body compression fractures: restoration and maintenance of height and stability.
    Kettler A; Schmoelz W; Shezifi Y; Ohana N; Ben-Arye A; Claes L; Wilke HJ
    Clin Biomech (Bristol, Avon); 2006 Aug; 21(7):676-82. PubMed ID: 16567025
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 30.