These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 19214691)

  • 1. Knee model of hydrodynamic lubrication during the gait cycle and the influence of prosthetic joint conformity.
    Pascau A; Guardia B; Puertolas JA; Gómez-Barrena E
    J Orthop Sci; 2009 Jan; 14(1):68-75. PubMed ID: 19214691
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Time-dependent elastohydrodynamic lubrication analysis of total knee replacement under walking conditions.
    Su Y; Yang P; Fu Z; Jin Z; Wang C
    Comput Methods Biomech Biomed Engin; 2011 Jun; 14(6):539-48. PubMed ID: 21390940
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 3-D model of a total hip replacement in vivo providing hydrodynamic pressure and film thickness for walking and bicycling.
    Meyer DM; Tichy JA
    J Biomech Eng; 2003 Dec; 125(6):777-84. PubMed ID: 14986401
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cushion form bearings for total knee joint replacement. Part 1: Design,friction and lubrication.
    Auger DD; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1995; 209(2):73-81. PubMed ID: 7495429
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of inserting a Fuji pressure sensitive film between the tibiofemoral joint of knee prosthesis on actual contact characteristics.
    Liau JJ; Hu CC; Cheng CK; Huang CH; Lo WH
    Clin Biomech (Bristol, Avon); 2001 Feb; 16(2):160-6. PubMed ID: 11222935
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A porous implant model for a knee joint.
    Tandon PN; Chaurasia A
    Int J Biomed Comput; 1991 Oct; 29(1):45-59. PubMed ID: 1959981
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of porosity of articular cartilage on the lubrication of a normal human hip joint.
    Jin ZM; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1992; 206(3):117-24. PubMed ID: 1482507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The John Charnley Award Paper. The role of joint fluid in the tribology of total joint arthroplasty.
    Mazzucco D; Spector M
    Clin Orthop Relat Res; 2004 Dec; (429):17-32. PubMed ID: 15577461
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
    Gao L; Wang F; Yang P; Jin Z
    Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prediction of transient lubricating film thickness in knee prostheses with compliant layers.
    Jin ZM; Dowson D; Fisher J; Ohtsuki N; Murakami T; Higaki H; Moriyama S
    Proc Inst Mech Eng H; 1998; 212(3):157-64. PubMed ID: 9695634
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effects of conformity and load in total knee replacement.
    Kuster MS; Horz S; Spalinger E; Stachowiak GW; Gächter A
    Clin Orthop Relat Res; 2000 Jun; (375):302-12. PubMed ID: 10853182
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical analysis of the effects of material parameters on the lubrication mechanism for knee prosthesis.
    Di Paolo J; Berli ME
    Comput Methods Biomech Biomed Engin; 2006 Apr; 9(2):79-89. PubMed ID: 16880159
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Asperity lubrication in human joints.
    Yao JQ; Unsworth A
    Proc Inst Mech Eng H; 1993; 207(4):245-54. PubMed ID: 7802876
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lubricating ability of aspirated synovial fluid from emergency department patients with knee joint synovitis.
    Jay GD; Elsaid KA; Zack J; Robinson K; Trespalacios F; Cha CJ; Chichester CO
    J Rheumatol; 2004 Mar; 31(3):557-64. PubMed ID: 14994405
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Phan-Thien and Tanner model applied to thin film spherical coordinates: applications for lubrication of hip joint replacement.
    Tichy J; Bou-Saïd B
    J Biomech Eng; 2008 Apr; 130(2):021012. PubMed ID: 18412499
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of knee joint muscle forces and tissue stresses-strains during gait in severe OA versus normal subjects.
    Adouni M; Shirazi-Adl A
    J Orthop Res; 2014 Jan; 32(1):69-78. PubMed ID: 24038150
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of albumin and γ-globulin on synovial fluid lubrication: Implication for knee joint replacements.
    Nečas D; Sadecká K; Vrbka M; Galandáková A; Wimmer MA; Gallo J; Hartl M
    J Mech Behav Biomed Mater; 2021 Jan; 113():104117. PubMed ID: 33065468
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    J Biomech; 2006; 39(5):905-14. PubMed ID: 16199048
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The biological role of the structural-deformable properties of the cartilage and of the synovial fluid in the reduction of intra- articular friction].
    Kupchinov BI; Ermakov SF; Rodnenkov VG; Beloenko ED
    Ortop Travmatol Protez; 1989 Oct; (10):7-11. PubMed ID: 2622643
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Elastohydrodynamic lubrication analysis of a functionally graded layered bearing surface, with particular reference to 'cushion form bearings' for artificial knee joints.
    Virdee SS; Wang FC; Xu H; Jin ZM
    Proc Inst Mech Eng H; 2003; 217(3):191-8. PubMed ID: 12807159
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.