124 related articles for article (PubMed ID: 19221093)
1. Rupture of a thoracic aorta pseudoaneurysm: rare presentation and role of real-time 3D transoesophageal echocardiography.
Salinas P; Lopez T; Gonzalez A; Pena-Conde L; Moreno R; Moreno M; Lopez-Sendon JL
Eur J Echocardiogr; 2009 May; 10(3):473-5. PubMed ID: 19221093
[TBL] [Abstract][Full Text] [Related]
2. Transesophageal echocardiographic artifact mimicking pseudoaneurysm of the aorta.
Hust MH; Metzler B; Claussnitzer R; Sebold H; Braun B
J Am Soc Echocardiogr; 1994; 7(5):538-41. PubMed ID: 7986552
[TBL] [Abstract][Full Text] [Related]
3. Transesophageal echocardiographic identification of left upper pulmonary venous obstruction caused by compression by spontaneous pseudoaneurysm of the descending thoracic aorta.
Ha JW; Chung N; Shim WH; Kim YW; Lee DI; Chung BY; Rim SJ; Chang BC; Lee DY
J Am Soc Echocardiogr; 1998 Oct; 11(10):992-6. PubMed ID: 9804108
[TBL] [Abstract][Full Text] [Related]
4. Superior vena cava syndrome caused by a pseudoaneurysm of the ascending aorta.
Vydt T; Coddens J; Wellens F
Heart; 2005 Apr; 91(4):e29. PubMed ID: 15772178
[TBL] [Abstract][Full Text] [Related]
5. Pseudoaneurysm of the descending aorta caused by Candida albicans.
Manso JV; de Salinas ES; Alvarez VB; Pena JC; Nava SH
Int J Cardiol; 1999 Oct; 71(2):185-7. PubMed ID: 10574405
[No Abstract] [Full Text] [Related]
6. Does three-dimensional transesophageal echocardiography provide incremental value in percutaneous closure of ascending aortic pseudoaneurysm?
Elkaryoni A; Hsiung MC; Arisha MJ; Ahmad A; Nanda NC; Mohamed AH; Attia D; Sachdeva A; Singh L; Yin WH
Echocardiography; 2017 Jul; 34(7):1057-1061. PubMed ID: 28664669
[TBL] [Abstract][Full Text] [Related]
7. Surgery for pseudoaneurysm of the ascending aorta: role of intraoperative 2-dimensional and real-time 3-dimensional transesophageal echocardiography.
Gadhinglajkar S; Sreedhar R
J Cardiothorac Vasc Anesth; 2010 Oct; 24(5):906-8. PubMed ID: 20138784
[No Abstract] [Full Text] [Related]
8. Images in cardio-thoracic surgery: Ruptured pseudoaneurysm with aorto-pulmonary shunt after aortic arch repair.
Loup O; Ott D; Englberger L; Carrel T
Eur J Cardiothorac Surg; 2009 May; 35(5):901. PubMed ID: 19278864
[No Abstract] [Full Text] [Related]
9. Expanding pseudoaneurysm compressing the coronary arteries and causing cardiogenic shock.
Maliske SM; Alshawabkeh L; Schouweiler K; Sigurdsson G
J Cardiovasc Comput Tomogr; 2015; 9(3):230-1. PubMed ID: 25708010
[TBL] [Abstract][Full Text] [Related]
10. Images in cardiology. Infective pseudoaneurysm of a ruptured sinus of Valsalva as an unusual cause of myocardial infarction by compression of the right coronary artery.
Cayla G; Macia JC; Pasquié JL
Heart; 2006 Jun; 92(6):831. PubMed ID: 16698835
[No Abstract] [Full Text] [Related]
11. Pseudoaneurysm of the thoracic aorta presenting as purulent pericarditis and pericardial effusion.
Aranda J; Tauth J; Henning RJ; O'Hara M
Cathet Cardiovasc Diagn; 1998 Jan; 43(1):63-7. PubMed ID: 9473194
[TBL] [Abstract][Full Text] [Related]
12. Acute Diastolic Heart Dysfunction Caused by Ruptured Descending Thoracic Aortic Aneurysm with Posterior Mediastinal Hematoma.
Nagata T; Hirai Y; Wang Y; Nohara T
J Card Surg; 2015 Jul; 30(7):589-90. PubMed ID: 25989223
[No Abstract] [Full Text] [Related]
13. Mycotic pseudoaneurysm of the ascending aorta.
de Agustin JA; Gomez de Diego JJ; Rodrigo JL; Macaya C; Perez de Isla L
Eur Heart J Cardiovasc Imaging; 2014 Jun; 15(6):715. PubMed ID: 24408935
[No Abstract] [Full Text] [Related]
14. Case images: Cardiogenic shock caused by huge para-aortic hematoma and pseudoaneurysm after Bentall operation.
Sunman H; Erat M; Doğan M; Yeter E
Turk Kardiyol Dern Ars; 2014 Jun; 42(4):414. PubMed ID: 24899493
[No Abstract] [Full Text] [Related]
15. [Pseudoaneurysm of the thoracic aorta diagnosed by transesophageal echocardiography].
Apró D; Motyovszki A; Mezey B
Orv Hetil; 1998 Mar; 139(10):565-7. PubMed ID: 9538641
[TBL] [Abstract][Full Text] [Related]
16. Atherosclerotic aortic rupture: documentation by transesophageal echocardiography.
Vilacosta I; San Román JA; Aragoncillo P
J Am Soc Echocardiogr; 2001 Feb; 14(2):152-4. PubMed ID: 11174450
[TBL] [Abstract][Full Text] [Related]
17. Comprehensive imaging including three-dimensional echocardiography of an infected, ruptured sinus of valsalva aneurysm.
Medina HM; Vazquez J; Pritchett A; Lakkis N; Dokainish H
Echocardiography; 2007 Nov; 24(10):1096-8. PubMed ID: 18001366
[TBL] [Abstract][Full Text] [Related]
18. [Clinical significance of transesophageal echocardiography for evaluation of patients after Bentall's operation: detection of graft failure].
Ishizuka N; Sakai K; Nakagawa M; Niki K; Fujita Y; Tanimoto K; Nakamura K; Hosoda S; Hashimoto A; Koyanagi H
J Cardiol; 1995 Mar; 25(3):139-46. PubMed ID: 7722875
[TBL] [Abstract][Full Text] [Related]
19. [Traumatic rupture of the descending aorta].
Kovács E; Dzsinich C; Gyöngy T; Moravcsik E; Szabolcs Z; Bodor E
Orv Hetil; 1997 Sep; 138(39):2461-5. PubMed ID: 9380385
[TBL] [Abstract][Full Text] [Related]
20. [Diagnosis of pseudoaneurysm of the ascending aorta after implantation of a valved conduit by multiplane transesophageal echocardiography].
Beyer ME; Voelker W; Hoffmeister HM
Z Kardiol; 1994 Aug; 83(8):595-8. PubMed ID: 7975811
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]