These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
60 related articles for article (PubMed ID: 19231267)
1. Role of "the frame cycle time" in portal dose imaging using an aS500-II EPID. Al Kattar Elbalaa Z; Foulquier JN; Orthuon A; Elbalaa H; Touboul E Phys Med; 2009 Sep; 25(3):148-53. PubMed ID: 19231267 [TBL] [Abstract][Full Text] [Related]
2. Optimization of image quality and dose for Varian aS500 electronic portal imaging devices (EPIDs). McGarry CK; Grattan MW; Cosgrove VP Phys Med Biol; 2007 Dec; 52(23):6865-77. PubMed ID: 18029980 [TBL] [Abstract][Full Text] [Related]
3. A literature review of electronic portal imaging for radiotherapy dosimetry. van Elmpt W; McDermott L; Nijsten S; Wendling M; Lambin P; Mijnheer B Radiother Oncol; 2008 Sep; 88(3):289-309. PubMed ID: 18706727 [TBL] [Abstract][Full Text] [Related]
4. Assessment of dosimetrical performance in 11 Varian a-Si-500 electronic portal imaging devices. Kavuma A; Glegg M; Currie G; Elliott A Phys Med Biol; 2008 Dec; 53(23):6893-909. PubMed ID: 19001691 [TBL] [Abstract][Full Text] [Related]
5. Performance optimization of the Varian aS500 EPID system. Berger L; François P; Gaboriaud G; Rosenwald JC J Appl Clin Med Phys; 2006; 7(1):105-14. PubMed ID: 16518322 [TBL] [Abstract][Full Text] [Related]
6. [Quality assurance of enhanced dynamic wedge using the aS500-II, EPID]. Al kattar El balaa Z; Foulquier JN; El balaa H; Orthuon A; Touboul E Cancer Radiother; 2009 Dec; 13(8):731-9. PubMed ID: 19854091 [TBL] [Abstract][Full Text] [Related]
7. Verification of dose delivery for a prostate sIMRT treatment using a SLIC-EPID. Mohammadi M; Bezak E; Reich P Appl Radiat Isot; 2008 Dec; 66(12):1930-8. PubMed ID: 18583141 [TBL] [Abstract][Full Text] [Related]
8. Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification. Vetterli D; Riem H; Aebersold DM; Greiner RH; Manser P; Cossmann P; Kemmerling L; Born EJ; Mini R Med Phys; 2004 Apr; 31(4):828-31. PubMed ID: 15125000 [TBL] [Abstract][Full Text] [Related]
10. Study of X-ray field junction dose using an a-Si electronic portal imaging device. Madebo M; Perkins A; Fox C; Johnston P; Kron T Australas Phys Eng Sci Med; 2010 Mar; 33(1):45-50. PubMed ID: 20237889 [TBL] [Abstract][Full Text] [Related]
11. Dose-response characteristics of an amorphous silicon EPID. Winkler P; Hefner A; Georg D Med Phys; 2005 Oct; 32(10):3095-105. PubMed ID: 16279061 [TBL] [Abstract][Full Text] [Related]
12. QA of dynamic MLC based on EPID portal dosimetry. Richart J; Pujades MC; Perez-Calatayud J; Granero D; Ballester F; Rodriguez S; Santos M Phys Med; 2012 Jul; 28(3):262-8. PubMed ID: 21784685 [TBL] [Abstract][Full Text] [Related]
13. Effect of delay between erasure and image acquisition in CR. Al Khalifah KH; Brindhaban A Radiol Technol; 2011; 82(3):214-8. PubMed ID: 21209423 [TBL] [Abstract][Full Text] [Related]
14. An intercomparison of 11 amorphous silicon EPIDs of the same type: implications for portal dosimetry. Winkler P; Georg D Phys Med Biol; 2006 Sep; 51(17):4189-200. PubMed ID: 16912376 [TBL] [Abstract][Full Text] [Related]
15. The Influence of Acquisition Mode on the Dosimetric Performance of an Amorphous Silicon Electronic Portal Imaging Device. Bawazeer O; Herath S; Sarasanandarajah S; Kron T; Deb P J Med Phys; 2017; 42(2):90-95. PubMed ID: 28706355 [TBL] [Abstract][Full Text] [Related]
16. Poster - Thur Eve - 43: Is faster always better? An evaluation of frame rate effects on continuous acquisition mode EPID imaging for dose verification. Peca S; Granville D; Brown D Med Phys; 2012 Jul; 39(7Part3):4632. PubMed ID: 28516714 [TBL] [Abstract][Full Text] [Related]