783 related articles for article (PubMed ID: 19232945)
1. Combination of Airway Scope and bougie for a full-stomach patient with difficult intubation caused by unanticipated anatomical factors and cricoid pressure.
Takenaka I; Aoyama K; Kinoshita Y; Iwagaki T; Ishimura H; Takenaka Y; Kadoya T
J Clin Anesth; 2009 Feb; 21(1):64-6. PubMed ID: 19232945
[TBL] [Abstract][Full Text] [Related]
2. [Efficacy of bougie in difficult intubation with the Airway Scope caused by inability to lift the epiglottis directly].
Seto A; Takenaka I; Aoyama K; Iwagaki T; Ishimura H; Takenaka Y; Kadoya T
Masui; 2010 Apr; 59(4):525-30. PubMed ID: 20420153
[TBL] [Abstract][Full Text] [Related]
3. [Optical and video-assisted laryngoscopy for problematic airways].
Johansen M; Afshari A; Kristensen BB
Ugeskr Laeger; 2009 Nov; 171(48):3528-30. PubMed ID: 19944053
[TBL] [Abstract][Full Text] [Related]
4. Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study.
Koyama Y; Inagawa G; Miyashita T; Kikuchi T; Miura N; Miki T; Kurihara R; Kamiya Y; Goto T
Anaesthesia; 2007 Sep; 62(9):936-9. PubMed ID: 17697222
[TBL] [Abstract][Full Text] [Related]
5. Comparison of direct and video-assisted views of the larynx during routine intubation.
Kaplan MB; Hagberg CA; Ward DS; Brambrink A; Chhibber AK; Heidegger T; Lozada L; Ovassapian A; Parsons D; Ramsay J; Wilhelm W; Zwissler B; Gerig HJ; Hofstetter C; Karan S; Kreisler N; Pousman RM; Thierbach A; Wrobel M; Berci G
J Clin Anesth; 2006 Aug; 18(5):357-62. PubMed ID: 16905081
[TBL] [Abstract][Full Text] [Related]
6. Comparison of the Levitan FPS Scope and the single-use bougie for simulated difficult intubation in anaesthetised patients.
Greenland KB; Liu G; Tan H; Edwards M; Irwin MG
Anaesthesia; 2007 May; 62(5):509-15. PubMed ID: 17448065
[TBL] [Abstract][Full Text] [Related]
7. [Pentax AWS airway scope].
Asai T; Enomoto Y; Shingu K; Okuda Y
Masui; 2007 Jul; 56(7):862-5. PubMed ID: 17633856
[TBL] [Abstract][Full Text] [Related]
8. The Parker Flex-Tip tube is useful for Airway Scope-assisted intubation.
Kitagawa H; Imashuku Y; Yamazaki T
J Clin Anesth; 2010 Jun; 22(4):307. PubMed ID: 20522368
[No Abstract] [Full Text] [Related]
9. The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.
Suzuki A; Toyama Y; Katsumi N; Kunisawa T; Sasaki R; Hirota K; Henderson JJ; Iwasaki H
Anaesthesia; 2008 Jun; 63(6):641-7. PubMed ID: 18477277
[TBL] [Abstract][Full Text] [Related]
10. [Successful nasal intubation using airway scope with gum elastic bougie in a case of difficult airway].
Inoue H; Saito T; Kamishima K; Okano T; Kuno Y; Arai T; Okuda Y
Masui; 2008 Apr; 57(4):457-9. PubMed ID: 18416204
[TBL] [Abstract][Full Text] [Related]
11. Comparison of a disposable bougie versus a newly designed malleable bougie in the intubation of a difficult manikin airway.
Boedeker BH; Bernhagen M; Miller DJ; Murray WB
Stud Health Technol Inform; 2011; 163():65-7. PubMed ID: 21335760
[TBL] [Abstract][Full Text] [Related]
12. GlideScope-assisted double-lumen endobronchial tube placement in a patient with an unanticipated difficult airway.
Chen A; Lai HY; Lin PC; Chen TY; Shyr MH
J Cardiothorac Vasc Anesth; 2008 Feb; 22(1):170-2. PubMed ID: 18249357
[No Abstract] [Full Text] [Related]
13. A novel technique using the gum elastic bougie and video laryngoscope for intubation in an unanticipated difficult airway.
Hand WR; Sutton BM
J Clin Anesth; 2012 Dec; 24(8):675-7. PubMed ID: 23228873
[No Abstract] [Full Text] [Related]
14. Awake fiberoptic intubation using an optical stylet in an anticipated difficult airway.
Kovacs G; Law AJ; Petrie D
Ann Emerg Med; 2007 Jan; 49(1):81-3. PubMed ID: 17141147
[TBL] [Abstract][Full Text] [Related]
15. [Usability of AirWay Scope for awake tracheal intubation in a burn patient with difficult airway].
Kato T; Kusunoki S; Kawamoto M; Yuge O
Masui; 2007 Oct; 56(10):1179-81. PubMed ID: 17966622
[TBL] [Abstract][Full Text] [Related]
16. The "jaw thrust" maneuver rather than the "BURP" maneuver improves the glottic view for Pentax-AWS assisted tracheal intubation in a patient with a laryngeal aperture.
Kitagawa H; Yamazaki T; Imashuku Y
Can J Anaesth; 2010 May; 57(5):517-8. PubMed ID: 20151339
[No Abstract] [Full Text] [Related]
17. Use of the video laryngoscopy for Combitube exchange in a difficult airway.
Lam NC; Hagberg CA; Bassili LM
J Clin Anesth; 2009 Jun; 21(4):294-6. PubMed ID: 19502024
[TBL] [Abstract][Full Text] [Related]
18. Airway scope for tracheal intubation in the lateral position.
Komatsu R; Kamata K; You J; Sessler DI; Kasuya Y
Anesth Analg; 2011 Apr; 112(4):868-74. PubMed ID: 21385975
[TBL] [Abstract][Full Text] [Related]
19. [Use of a gum elastic bougie for tracheal intubation with Pentax-AWS airway scope].
Ueshima H; Asai T; Shingu K; Inoue H; Hashimoto Y; Enomoto Y; Okuda Y
Masui; 2008 Jan; 57(1):82-4. PubMed ID: 18214009
[TBL] [Abstract][Full Text] [Related]
20. Review of video laryngoscopy and rigid fiberoptic laryngoscopy.
Pott LM; Murray WB
Curr Opin Anaesthesiol; 2008 Dec; 21(6):750-8. PubMed ID: 18997526
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]