606 related articles for article (PubMed ID: 19235237)
1. Differences of platelet adhesion and thrombus activation on amorphous silicon carbide, magnesium alloy, stainless steel, and cobalt chromium stent surfaces.
Hansi C; Arab A; Rzany A; Ahrens I; Bode C; Hehrlein C
Catheter Cardiovasc Interv; 2009 Mar; 73(4):488-96. PubMed ID: 19235237
[TBL] [Abstract][Full Text] [Related]
2. Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion during platelet activation.
Monnink SH; van Boven AJ; Peels HO; Tigchelaar I; de Kam PJ; Crijns HJ; van Oeveren W
J Investig Med; 1999 Jul; 47(6):304-10. PubMed ID: 10431485
[TBL] [Abstract][Full Text] [Related]
3. Influence of surface texture and charge on the biocompatibility of endovascular stents.
Hehrlein C; Zimmermann M; Metz J; Ensinger W; Kübler W
Coron Artery Dis; 1995 Jul; 6(7):581-6. PubMed ID: 7582197
[TBL] [Abstract][Full Text] [Related]
4. [Mechanical analysis on a new type of biodegradable magnesium-alloy stent].
Wang X; Cui F; Li J; Zhao X
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Apr; 26(2):338-41. PubMed ID: 19499798
[TBL] [Abstract][Full Text] [Related]
5. Haemocompatibility of polymer-coated stainless steel stents as compared to uncoated stents.
Mrowietz C; Franke RP; Seyfert UT; Park JW; Jung F
Clin Hemorheol Microcirc; 2005; 32(2):89-103. PubMed ID: 15764818
[TBL] [Abstract][Full Text] [Related]
6. Polymer stent coating for prevention of neointimal hyperplasia.
Billinger M; Buddeberg F; Hubbell JA; Elbert DL; Schaffner T; Mettler D; Windecker S; Meier B; Hess OM
J Invasive Cardiol; 2006 Sep; 18(9):423-6; discussion 427. PubMed ID: 16954581
[TBL] [Abstract][Full Text] [Related]
7. [Coronary endoprostheses (stents)].
Sigwart U
Herz; 1990 Oct; 15(5):319-28. PubMed ID: 2227767
[TBL] [Abstract][Full Text] [Related]
8. Periprocedural (30-day) risk of myocardial infarction after drug-eluting coronary stent implantation: a meta-analysis comparing cobalt-chromium and stainless steel drug-eluting coronary stents.
Moreno R; Jimenez-Valero S; Sanchez-Recalde A; Galeote G; Calvo L; Martin-Reyes R; Sabate M; Plaza I; Macaya C; Lopez-Sendon JL
EuroIntervention; 2011 Mar; 6(8):1003-10. PubMed ID: 21330250
[TBL] [Abstract][Full Text] [Related]
9. Comparing coronary stent material performance on a common geometric platform through simulated bench testing.
Grogan JA; Leen SB; McHugh PE
J Mech Behav Biomed Mater; 2012 Aug; 12():129-38. PubMed ID: 22705476
[TBL] [Abstract][Full Text] [Related]
10. Clinical investigation into the observation that silicon carbide coating on cobalt chromium stents leads to early differentiating functional endothelial layer, increased safety and DES-like recurrent stenosis rates: results of the PRO-Heal Registry (PRO-Kinetic enhancing rapid in-stent endothelialisation).
Dahm JB; Willems T; Wolpers HG; Nordbeck H; Becker J; Ruppert J
EuroIntervention; 2009 Jan; 4(4):502-8. PubMed ID: 19284073
[TBL] [Abstract][Full Text] [Related]
11. The platinum chromium element stent platform: from alloy, to design, to clinical practice.
Menown IB; Noad R; Garcia EJ; Meredith I
Adv Ther; 2010 Mar; 27(3):129-41. PubMed ID: 20437213
[TBL] [Abstract][Full Text] [Related]
12. Comparison of thin-strut cobalt-chromium stents and stainless steel stents in a porcine model of neointimal hyperplasia.
Milewski K; Zurakowski A; Pajak J; Pajak-Zielinska E; Liszka L; Buszman PP; Bis J; Debinski M; Buszman PE
Med Sci Monit; 2010 Jan; 16(1):BR40-4. PubMed ID: 20037484
[TBL] [Abstract][Full Text] [Related]
13. Improved blood compatibility of rapamycin-eluting stent by incorporating curcumin.
Pan CJ; Tang JJ; Shao ZY; Wang J; Huang N
Colloids Surf B Biointerfaces; 2007 Sep; 59(1):105-11. PubMed ID: 17540543
[TBL] [Abstract][Full Text] [Related]
14. Reaction to injury following balloon angioplasty and intravascular stent placement in the canine femoral artery.
Salam TA; Taylor B; Suggs WD; Hanson SR; Lumsden AB
Am Surg; 1994 May; 60(5):353-7. PubMed ID: 8161086
[TBL] [Abstract][Full Text] [Related]
15. Intravascular ultrasound assessment of cobalt chromium versus stainless steel drug-eluting stent expansion.
He Y; Maehara A; Mintz GS; Bharaj H; Castellanos C; Kesanakurthy S; Wu X; Guo N; Choi SY; Leon MB; Stone GW; Mehran R; Rabbani LE; Moses JW
Am J Cardiol; 2010 May; 105(9):1272-5. PubMed ID: 20403478
[TBL] [Abstract][Full Text] [Related]
16. Reduction of late in-stent stenosis in a porcine coronary artery model by cobalt chromium stents with a nanocoat of polyphosphazene (Polyzene-F).
Stampfl U; Sommer CM; Thierjung H; Stampfl S; Lopez-Benitez R; Radeleff B; Berger I; Richter GM
Cardiovasc Intervent Radiol; 2008; 31(6):1184-92. PubMed ID: 18704573
[TBL] [Abstract][Full Text] [Related]
17. A thromboxane A2/prostaglandin H2 receptor antagonist (S18886) shows high antithrombotic efficacy in an experimental model of stent-induced thrombosis.
Vilahur G; Casaní L; Badimon L
Thromb Haemost; 2007 Sep; 98(3):662-9. PubMed ID: 17849057
[TBL] [Abstract][Full Text] [Related]
18. Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model.
Thierry B; Merhi Y; Bilodeau L; Trépanier C; Tabrizian M
Biomaterials; 2002 Jul; 23(14):2997-3005. PubMed ID: 12069342
[TBL] [Abstract][Full Text] [Related]
19. Inhibition of platelet thrombosis using an activated protein C-loaded stent: in vitro and in vivo results.
Foo RS; Gershlick AH; Hogrefe K; Baron JH; Johnston TW; Hussey AJ; Garner I; de Bono DP
Thromb Haemost; 2000 Mar; 83(3):496-502. PubMed ID: 10744160
[TBL] [Abstract][Full Text] [Related]
20. Environmental influences on endovascular stent platelet reactivity: an in vitro comparison of stainless steel and gold surfaces.
Kolandaivelu K; Edelman ER
J Biomed Mater Res A; 2004 Aug; 70(2):186-93. PubMed ID: 15227663
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]