BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 19235375)

  • 1. A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.
    Sakhalkar HS; Adamovics J; Ibbott G; Oldham M
    Med Phys; 2009 Jan; 36(1):71-82. PubMed ID: 19235375
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using presage/optical-CT.
    Sakhalkar H; Sterling D; Adamovics J; Ibbott G; Oldham M
    Med Phys; 2009 Jul; 36(7):3371-7. PubMed ID: 19673232
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An Investigation into the Robustness of Optical-CT Dosimetry of a Radiochromic Dosimeter Compatible with the RPC Head-and-Neck Phantom.
    Sakhalkar HS; Adamovics J; Ibbott G; Oldham M
    J Phys Conf Ser; 2009 Jan; 164(1):12059. PubMed ID: 20407594
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a 3D remote dosimetry protocol compatible with MRgIMRT.
    Mein S; Rankine L; Adamovics J; Li H; Oldham M
    Med Phys; 2017 Nov; 44(11):6018-6028. PubMed ID: 28877344
    [TBL] [Abstract][Full Text] [Related]  

  • 5. On the feasibility of comprehensive high-resolution 3D remote dosimetry.
    Juang T; Grant R; Adamovics J; Ibbott G; Oldham M
    Med Phys; 2014 Jul; 41(7):071706. PubMed ID: 24989375
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A practical three-dimensional dosimetry system for radiation therapy.
    Guo P; Adamovics J; Oldham M
    Med Phys; 2006 Oct; 33(10):3962-72. PubMed ID: 17089858
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.
    Sakhalkar HS; Oldham M
    Med Phys; 2008 Jan; 35(1):101-11. PubMed ID: 18293567
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.
    Bache ST; Juang T; Belley MD; Koontz BF; Adamovics J; Yoshizumi TT; Kirsch DG; Oldham M
    Med Phys; 2015 Feb; 42(2):846-55. PubMed ID: 25652497
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Temperature dependence and temporal stability of stacked radiochromic sheets for three-dimensional dose verification.
    Liu K; Wang YF; Dona Lemus OM; Adamovics J; Wuu CS
    Med Phys; 2020 Nov; 47(11):5906-5918. PubMed ID: 32996168
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of a new radiochromic three-dimensional dosimeter.
    Guo PY; Adamovics JA; Oldham M
    Med Phys; 2006 May; 33(5):1338-45. PubMed ID: 16752569
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGEĀ® radiochromic plastic.
    Palmer AL; Di Pietro P; Alobaidli S; Issa F; Doran S; Bradley D; Nisbet A
    Med Phys; 2013 Jun; 40(6):061707. PubMed ID: 23718586
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation into the feasibility of using PRESAGE/optical-CT dosimetry for the verification of gating treatments.
    Brady SL; Brown WE; Clift CG; Yoo S; Oldham M
    Phys Med Biol; 2010 Apr; 55(8):2187-201. PubMed ID: 20348606
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of an anthropomorphic PRESAGEĀ® dosimeter and radiochromic film with a commercial radiation treatment planning system for breast IMRT: a feasibility study.
    Iqbal K; Gifford KA; Ibbott G; Grant RL; Buzdar S
    J Appl Clin Med Phys; 2014 Jan; 15(1):4531. PubMed ID: 24423854
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Investigating the Feasibility of 3D Dosimetry in the RPC IMRT H&N Phantom.
    Sakhalkar H; Sterling D; Adamovics J; Ibbott G; Oldham M
    J Phys Conf Ser; 2009; 164(2009):12058. PubMed ID: 20333319
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Initial evaluation of commercial optical CT-based 3D gel dosimeter.
    Islam KT; Dempsey JF; Ranade MK; Maryanski MJ; Low DA
    Med Phys; 2003 Aug; 30(8):2159-68. PubMed ID: 12945982
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance of a commercial optical CT scanner and polymer gel dosimeters for 3-D dose verification.
    Xu Y; Wuu CS; Maryanski MJ
    Med Phys; 2004 Nov; 31(11):3024-33. PubMed ID: 15587656
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry.
    Wuu CS; Xu Y
    Med Phys; 2006 May; 33(5):1412-9. PubMed ID: 16752577
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation of a 3D dosimetry system utilizing radio-chromic gel and telecentric optical-CT readout.
    Hoopingarner S; Oldham M; Adamson J; Lakrad K
    Med Phys; 2023 Sep; 50(9):5734-5744. PubMed ID: 37485846
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Commissioning a CT-compatible LDR tandem and ovoid applicator using Monte Carlo calculation and 3D dosimetry.
    Adamson J; Newton J; Yang Y; Steffey B; Cai J; Adamovics J; Oldham M; Chino J; Craciunescu O
    Med Phys; 2012 Jul; 39(7):4515-23. PubMed ID: 22830783
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System.
    Rankine LJ; Mein S; Cai B; Curcuru A; Juang T; Miles D; Mutic S; Wang Y; Oldham M; Li HH
    Int J Radiat Oncol Biol Phys; 2017 Apr; 97(5):1095-1104. PubMed ID: 28332995
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.