637 related articles for article (PubMed ID: 19235377)
1. Effect of nonlinear three-dimensional optimized reconstruction algorithm filter on image quality and radiation dose: validation on phantoms.
Bai M; Chen J; Raupach R; Suess C; Tao Y; Peng M
Med Phys; 2009 Jan; 36(1):95-7. PubMed ID: 19235377
[TBL] [Abstract][Full Text] [Related]
2. Spatial resolution improvement and dose reduction potential for inner ear CT imaging using a z-axis deconvolution technique.
McCollough CH; Leng S; Sunnegardh J; Vrieze TJ; Yu L; Lane J; Raupach R; Stierstorfer K; Flohr T
Med Phys; 2013 Jun; 40(6):061904. PubMed ID: 23718595
[TBL] [Abstract][Full Text] [Related]
3. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study.
Kim H; Park CM; Song YS; Lee SM; Goo JM
Eur J Radiol; 2014 May; 83(5):848-57. PubMed ID: 24572380
[TBL] [Abstract][Full Text] [Related]
4. Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners.
Ay MR; Mehranian A; Maleki A; Ghadiri H; Ghafarian P; Zaidi H
Phys Med; 2013 May; 29(3):249-60. PubMed ID: 22541061
[TBL] [Abstract][Full Text] [Related]
5. Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques.
Yamada Y; Jinzaki M; Hosokawa T; Tanami Y; Sugiura H; Abe T; Kuribayashi S
Eur J Radiol; 2012 Dec; 81(12):4185-95. PubMed ID: 22883532
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of z-axis resolution and image noise for nonconstant velocity spiral CT data reconstructed using a weighted 3D filtered backprojection (WFBP) reconstruction algorithm.
Christner JA; Stierstorfer K; Primak AN; Eusemann CD; Flohr TG; McCollough CH
Med Phys; 2010 Feb; 37(2):897-906. PubMed ID: 20229899
[TBL] [Abstract][Full Text] [Related]
7. Volume-of-interest (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose.
Kolditz D; Kyriakou Y; Kalender WA
Med Phys; 2010 Jun; 37(6):2719-30. PubMed ID: 20632582
[TBL] [Abstract][Full Text] [Related]
8. Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection.
Matsuki M; Murakami T; Juri H; Yoshikawa S; Narumi Y
Acta Radiol; 2013 Oct; 54(8):869-75. PubMed ID: 23761554
[TBL] [Abstract][Full Text] [Related]
9. Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v.
Lim K; Kwon H; Cho J; Oh J; Yoon S; Kang M; Ha D; Lee J; Kang E
J Comput Assist Tomogr; 2015; 39(3):443-8. PubMed ID: 25654782
[TBL] [Abstract][Full Text] [Related]
10. Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT.
Borgen L; Kalra MK; Laerum F; Hachette IW; Fredriksson CH; Sandborg M; Smedby O
Acta Radiol; 2012 Apr; 53(3):335-42. PubMed ID: 22362136
[TBL] [Abstract][Full Text] [Related]
11. Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom.
Paul J; Krauss B; Banckwitz R; Maentele W; Bauer RW; Vogl TJ
Eur J Radiol; 2012 May; 81(5):e699-703. PubMed ID: 21316888
[TBL] [Abstract][Full Text] [Related]
12. Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology.
Price RG; Vance S; Cattaneo R; Schultz L; Elshaikh MA; Chetty IJ; Glide-Hurst CK
Med Phys; 2014 Aug; 41(8):081907. PubMed ID: 25086538
[TBL] [Abstract][Full Text] [Related]
13. Ray contribution masks for structure adaptive sinogram filtering.
Balda M; Hornegger J; Heismann B
IEEE Trans Med Imaging; 2012 Jun; 31(6):1228-39. PubMed ID: 22333988
[TBL] [Abstract][Full Text] [Related]
14. Improvements to image quality using hybrid and model-based iterative reconstructions: a phantom study.
Aurumskjöld ML; Ydström K; Tingberg A; Söderberg M
Acta Radiol; 2017 Jan; 58(1):53-61. PubMed ID: 26924832
[TBL] [Abstract][Full Text] [Related]
15. Simulated dose reduction by adding artificial noise to measured raw data: a validation study.
Söderberg M; Gunnarsson M; Nilsson M
Radiat Prot Dosimetry; 2010; 139(1-3):71-7. PubMed ID: 20172933
[TBL] [Abstract][Full Text] [Related]
16. Spectrotemporal CT data acquisition and reconstruction at low dose.
Clark DP; Lee CL; Kirsch DG; Badea CT
Med Phys; 2015 Nov; 42(11):6317-36. PubMed ID: 26520724
[TBL] [Abstract][Full Text] [Related]
17. Preliminary results: prospective clinical study to assess image-based iterative reconstruction for abdominal computed tomography acquired at 2 radiation dose levels.
Pourjabbar S; Singh S; Singh AK; Johnston RP; Shenoy-Bhangle AS; Do S; Padole A; Blake MA; Persson A; Kalra MK
J Comput Assist Tomogr; 2014; 38(1):117-22. PubMed ID: 24424560
[TBL] [Abstract][Full Text] [Related]
18. Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm: A Phantom Study.
Onishi H; Kockelkoren R; Kim T; Hori M; Nakamoto A; Tsuboyama T; Sakane M; Tatsumi M; Uranishi A; Tanaka T; Taniguchi A; Enchi Y; Satoh K; Tomiyama N
J Comput Assist Tomogr; 2015; 39(4):629-34. PubMed ID: 26125298
[TBL] [Abstract][Full Text] [Related]
19. Automatic exposure control in pediatric and adult multidetector CT examinations: a phantom study on dose reduction and image quality.
Papadakis AE; Perisinakis K; Damilakis J
Med Phys; 2008 Oct; 35(10):4567-76. PubMed ID: 18975703
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT.
Matenine D; Mascolo-Fortin J; Goussard Y; Després P
Med Phys; 2015 Nov; 42(11):6376-86. PubMed ID: 26520729
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]