219 related articles for article (PubMed ID: 1923663)
1. Effects of endotracheal tube size and ventilator settings on the mechanics of a test system during intermittent flow ventilation. Farstad T; Bratlid D Pediatr Pulmonol; 1991; 11(1):15-21. PubMed ID: 1923663 [TBL] [Abstract][Full Text] [Related]
2. Effect of Endotracheal Tube Size, Respiratory System Mechanics, and Ventilator Settings on Driving Pressure. Ilia S; van Schelven PD; Koopman AA; Blokpoel RGT; de Jager P; Burgerhof JGM; Markhorst DG; Kneyber MCJ Pediatr Crit Care Med; 2020 Jan; 21(1):e47-e51. PubMed ID: 31688716 [TBL] [Abstract][Full Text] [Related]
3. An in vitro evaluation of the influence of neonatal endotracheal tube diameter and length on the work of breathing. Miyake F; Suga R; Akiyama T; Namba F Paediatr Anaesth; 2018 May; 28(5):458-462. PubMed ID: 29633434 [TBL] [Abstract][Full Text] [Related]
4. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings. Hentschel R; Buntzel J; Guttmann J; Schumann S Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238 [TBL] [Abstract][Full Text] [Related]
5. Pressure support compensation for inspiratory work due to endotracheal tubes and demand continuous positive airway pressure. Fiastro JF; Habib MP; Quan SF Chest; 1988 Mar; 93(3):499-505. PubMed ID: 3277803 [TBL] [Abstract][Full Text] [Related]
6. Reduced airway resistance and work of breathing during mechanical ventilation with an ultra-thin, two-stage polyurethane endotracheal tube (the Kolobow tube). Velarde CA; Short BL; Rivera O; Seale W; Howard R; Kolobow T Crit Care Med; 1997 Feb; 25(2):276-9. PubMed ID: 9034264 [TBL] [Abstract][Full Text] [Related]
7. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system. Banner MJ; Blanch PB; Kirby RR Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467 [TBL] [Abstract][Full Text] [Related]
8. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation. Uchiyama A; Yoshida T; Yamanaka H; Fujino Y Respir Care; 2013 Jul; 58(7):1157-69. PubMed ID: 23232731 [TBL] [Abstract][Full Text] [Related]
9. Work of breathing for cuffed and uncuffed pediatric endotracheal tubes in an in vitro lung model setting. Thomas J; Weiss M; Cannizzaro V; Both CP; Schmidt AR Paediatr Anaesth; 2018 Sep; 28(9):780-787. PubMed ID: 30004614 [TBL] [Abstract][Full Text] [Related]
10. Higher Fresh Gas Flow Rates Decrease Tidal Volume During Pressure Control Ventilation. Mohammad S; Gravenstein N; Gonsalves D; Vasilopoulos T; Lampotang S Anesth Analg; 2017 May; 124(5):1506-1511. PubMed ID: 28333703 [TBL] [Abstract][Full Text] [Related]
11. [Added work of breathing, respiratory pattern and determination of ventilator weaning readiness in inspiratory pressure support and and automatic tube compensation]. Stocker R; Fabry B; Stein S; Zappe D; Trentz O; Haberthür C Unfallchirurg; 1996 Oct; 99(10):764-70. PubMed ID: 9005565 [TBL] [Abstract][Full Text] [Related]
12. A new endotracheal tube for infants--laboratory and clinical assessment: a preliminary study. Stankiewicz B; Darowski M; Glapiński J; Rawicz M; Michnikowski M; Guć M; Kuraszkiewicz B Paediatr Anaesth; 2013 May; 23(5):440-5. PubMed ID: 23445272 [TBL] [Abstract][Full Text] [Related]
13. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [TBL] [Abstract][Full Text] [Related]
14. Comparison of inspiratory work of breathing between flow-triggered and pressure-triggered demand flow systems in rabbits. Nishimura M; Imanaka H; Yoshiya I; Kacmarek RM Crit Care Med; 1994 Jun; 22(6):1002-9. PubMed ID: 8205807 [TBL] [Abstract][Full Text] [Related]
15. Airway leak size in neonates and autocycling of three flow-triggered ventilators. Bernstein G; Knodel E; Heldt GP Crit Care Med; 1995 Oct; 23(10):1739-44. PubMed ID: 7587241 [TBL] [Abstract][Full Text] [Related]
16. Relationship of neonatal endotracheal tube size and airway resistance. Oca MJ; Becker MA; Dechert RE; Donn SM Respir Care; 2002 Sep; 47(9):994-7. PubMed ID: 12188933 [TBL] [Abstract][Full Text] [Related]
17. Compliance of the respiratory system as a predictor for successful extubation in very-low-birth-weight infants recovering from respiratory distress syndrome. Smith J; Pieper CH; Maree D; Gie RP S Afr Med J; 1999 Oct; 89(10):1097-102. PubMed ID: 10582068 [TBL] [Abstract][Full Text] [Related]
18. [The effect of different types of anesthetic respirators on oxygenation and ventilation in infants during short-term anesthesia. A study using transcutaneous PO2 and PCO2 monitoring]. Scheiber G; Hess W; Marichal A Anaesthesist; 1994 Aug; 43(8):510-20. PubMed ID: 7978174 [TBL] [Abstract][Full Text] [Related]
19. Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube. Cannon ML; Cornell J; Tripp-Hamel DS; Gentile MA; Hubble CL; Meliones JN; Cheifetz IM Am J Respir Crit Care Med; 2000 Dec; 162(6):2109-12. PubMed ID: 11112123 [TBL] [Abstract][Full Text] [Related]
20. Efficacy of pressure support in compensating for apparatus work. Bersten AD; Rutten AJ; Vedig AE Anaesth Intensive Care; 1993 Feb; 21(1):67-71. PubMed ID: 8447610 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]