257 related articles for article (PubMed ID: 19239071)
1. Applying tactile sensing with piezoelectric materials for minimally invasive surgery and magnetic-resonance-guided interventions.
Hamed AM; Tse ZT; Young I; Davies BL; Lampérth M
Proc Inst Mech Eng H; 2009 Jan; 223(1):99-110. PubMed ID: 19239071
[TBL] [Abstract][Full Text] [Related]
2. Magnetic resonance imaging-compatible tactile sensing device based on a piezoelectric array.
Hamed A; Masamune K; Tse ZT; Lamperth M; Dohi T
Proc Inst Mech Eng H; 2012 Jul; 226(7):565-75. PubMed ID: 22913103
[TBL] [Abstract][Full Text] [Related]
3. An indentation depth-force sensing wheeled probe for abnormality identification during minimally invasive surgery.
Liu H; Puangmali P; Zbyszewski D; Elhage O; Dasgupta P; Dai JS; Seneviratne L; Althoefer K
Proc Inst Mech Eng H; 2010; 224(6):751-63. PubMed ID: 20608492
[TBL] [Abstract][Full Text] [Related]
4. Integration of force reflection with tactile sensing for minimally invasive robotics-assisted tumor localization.
Talasaz A; Patel RV
IEEE Trans Haptics; 2013; 6(2):217-28. PubMed ID: 24808305
[TBL] [Abstract][Full Text] [Related]
5. A haptic unit designed for magnetic-resonance-guided biopsy.
Tse ZT; Elhawary H; Rea M; Young I; Davis BL; Lamperth M
Proc Inst Mech Eng H; 2009 Feb; 223(2):159-72. PubMed ID: 19278193
[TBL] [Abstract][Full Text] [Related]
6. An autoclavable wireless palpation instrument for minimally invasive surgery.
Naidu AS; Escoto A; Fahmy O; Patel RV; Naish MD
Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():6489-6492. PubMed ID: 28269733
[TBL] [Abstract][Full Text] [Related]
7. Discriminating contact in lumen with a moving flexible digit using fibre Bragg grating sensing elements.
Tam B; Ma X; Webb DJ; Holding DJ; Brett PN
Proc Inst Mech Eng H; 2010; 224(6):765-74. PubMed ID: 20608493
[TBL] [Abstract][Full Text] [Related]
8. Artificial palpation in robotic surgery using haptic feedback.
Abiri A; Juo YY; Tao A; Askari SJ; Pensa J; Bisley JW; Dutson EP; Grundfest WS
Surg Endosc; 2019 Apr; 33(4):1252-1259. PubMed ID: 30187198
[TBL] [Abstract][Full Text] [Related]
9. A flexible digit with tactile feedback for invasive clinical applications.
Ma X; Brett PN; Wright MT; Griffiths MV
Proc Inst Mech Eng H; 2004; 218(3):151-7. PubMed ID: 15239565
[TBL] [Abstract][Full Text] [Related]
10. Using visual cues to enhance haptic feedback for palpation on virtual model of soft tissue.
Li M; Konstantinova J; Secco EL; Jiang A; Liu H; Nanayakkara T; Seneviratne LD; Dasgupta P; Althoefer K; Wurdemann HA
Med Biol Eng Comput; 2015 Nov; 53(11):1177-86. PubMed ID: 26018755
[TBL] [Abstract][Full Text] [Related]
11. A review of force and resonance sensors used in the clinical study of tissue properties.
Yousuf MA; Asiyanbola BA
Proc Inst Mech Eng H; 2013 Dec; 227(12):1333-40. PubMed ID: 24048077
[TBL] [Abstract][Full Text] [Related]
12. Innovative optical microsystem for static and dynamic tissue diagnosis in minimally invasive surgical operations.
Ahmadi R; Packirisamy M; Dargahi J
J Biomed Opt; 2012 Aug; 17(8):081416. PubMed ID: 23224177
[TBL] [Abstract][Full Text] [Related]
13. An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device.
Su H; Shang W; Li G; Patel N; Fischer GS
Ann Biomed Eng; 2017 Aug; 45(8):1917-1928. PubMed ID: 28447178
[TBL] [Abstract][Full Text] [Related]
14. Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast.
Larson BT; Erdman AG; Tsekos NV; Yacoub E; Tsekos PV; Koutlas IG
J Biomech Eng; 2004 Aug; 126(4):458-65. PubMed ID: 15543863
[TBL] [Abstract][Full Text] [Related]
15. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.
Moradi Dalvand M; Shirinzadeh B; Nahavandi S; Smith J
Minim Invasive Ther Allied Technol; 2014 Jun; 23(3):127-35. PubMed ID: 24328984
[TBL] [Abstract][Full Text] [Related]
16. Force-feedback grasper helps restore sense of touch in minimally invasive surgery.
MacFarlane M; Rosen J; Hannaford B; Pellegrini C; Sinanan M
J Gastrointest Surg; 1999; 3(3):278-85. PubMed ID: 10481120
[TBL] [Abstract][Full Text] [Related]
17. Fabrication of a thin-film capacitive force sensor array for tactile feedback in robotic surgery.
Paydar OH; Wottawa CR; Fan RE; Dutson EP; Grundfest WS; Culjat MO; Candler RN
Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():2355-8. PubMed ID: 23366397
[TBL] [Abstract][Full Text] [Related]
18. MRI compatibility evaluation of a piezoelectric actuator system for a neural interventional robot.
Wang Y; Cole GA; Su H; Pilitsis JG; Fischer GS
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():6072-5. PubMed ID: 19964890
[TBL] [Abstract][Full Text] [Related]
19. Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey.
Shi C; Luo X; Qi P; Li T; Song S; Najdovski Z; Fukuda T; Ren H
IEEE Trans Biomed Eng; 2017 Aug; 64(8):1665-1678. PubMed ID: 27810796
[TBL] [Abstract][Full Text] [Related]
20. Mechatronic design of haptic forceps for robotic surgery.
Rizun P; Gunn D; Cox B; Sutherland G
Int J Med Robot; 2006 Dec; 2(4):341-9. PubMed ID: 17520653
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]