BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

295 related articles for article (PubMed ID: 19242050)

  • 1. Physical characterization and performance comparison of active- and passive-pixel CMOS detectors for mammography.
    Elbakri IA; McIntosh BJ; Rickey DW
    Phys Med Biol; 2009 Mar; 54(6):1743-55. PubMed ID: 19242050
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Physical characterization of a high-resolution CCD detector for mammography.
    Elbakri IA; Tesic MM; Xiong Q
    Phys Med Biol; 2007 Apr; 52(8):2171-83. PubMed ID: 17404462
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional cascaded system analysis of a 50 µm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.
    Zhao C; Vassiljev N; Konstantinidis AC; Speller RD; Kanicki J
    Phys Med Biol; 2017 Mar; 62(5):1994-2017. PubMed ID: 28072394
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Imaging performance of the hybrid pixel detectors XPAD3-S.
    Brunner FC; Clemens JC; Hemmer C; Morel C
    Phys Med Biol; 2009 Mar; 54(6):1773-89. PubMed ID: 19258683
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging.
    Arvanitis CD; Bohndiek SE; Royle G; Blue A; Liang HX; Clark A; Prydderch M; Turchetta R; Speller R
    Med Phys; 2007 Dec; 34(12):4612-25. PubMed ID: 18196789
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cascaded systems analysis of a-Se/a-Si and a-InGaZnO TFT passive and active pixel sensors for tomosynthesis.
    Sengupta A; Zhao C; Konstantinidis A; Kanicki J
    Phys Med Biol; 2019 Jan; 64(2):025012. PubMed ID: 30523916
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Large area CMOS active pixel sensor x-ray imager for digital breast tomosynthesis: Analysis, modeling, and characterization.
    Zhao C; Kanicki J; Konstantinidis AC; Patel T
    Med Phys; 2015 Nov; 42(11):6294-308. PubMed ID: 26520722
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization study of an intensified complementary metal-oxide-semiconductor active pixel sensor.
    Griffiths JA; Chen D; Turchetta R; Royle GJ
    Rev Sci Instrum; 2011 Mar; 82(3):033709. PubMed ID: 21456753
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.
    Cao Q; Sisniega A; Brehler M; Stayman JW; Yorkston J; Siewerdsen JH; Zbijewski W
    Med Phys; 2018 Jan; 45(1):114-130. PubMed ID: 29095489
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance.
    Sheth NM; Zbijewski W; Jacobson MW; Abiola G; Kleinszig G; Vogt S; Soellradl S; Bialkowski J; Anderson WS; Weiss CR; Osgood GM; Siewerdsen JH
    Med Phys; 2018 Dec; 45(12):5420-5436. PubMed ID: 30339271
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging.
    Esposito M; Anaxagoras T; Konstantinidis AC; Zheng Y; Speller RD; Evans PM; Allinson NM; Wells K
    Phys Med Biol; 2014 Jul; 59(13):3533-54. PubMed ID: 24909098
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.
    Zhao C; Konstantinidis AC; Zheng Y; Anaxagoras T; Speller RD; Kanicki J
    Phys Med Biol; 2015 Dec; 60(23):8977-9001. PubMed ID: 26540090
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detective quantum efficiency measured as a function of energy for two full-field digital mammography systems.
    Marshall NW
    Phys Med Biol; 2009 May; 54(9):2845-61. PubMed ID: 19384004
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Retrospective analysis of a detector fault for a full field digital mammography system.
    Marshall NW
    Phys Med Biol; 2006 Nov; 51(21):5655-73. PubMed ID: 17047276
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Imaging characteristics evaluation of a digital radiography system.
    Moro L; Pannella A; Bassetti C; Fantinato D; Baldi M; Bertoli G
    Radiol Med; 2003; 106(1-2):94-102. PubMed ID: 12951556
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of the performance of modern screen-film and digital mammography systems.
    Monnin P; Gutierrez D; Bulling S; Lepori D; Valley JF; Verdun FR
    Phys Med Biol; 2005 Jun; 50(11):2617-31. PubMed ID: 15901958
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.
    Zhao W; Ji WG; Debrie A; Rowlands JA
    Med Phys; 2003 Feb; 30(2):254-63. PubMed ID: 12607843
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Amorphous In-Ga-Zn-O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis.
    Zhao C; Kanicki J
    Med Phys; 2014 Sep; 41(9):091902. PubMed ID: 25186389
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Physical image properties of a complementary metal-oxide-semiconductor imager for mammography systems.
    Okamoto C; Kodera Y
    Radiol Phys Technol; 2018 Sep; 11(3):284-293. PubMed ID: 29845552
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography.
    El-Mohri Y; Antonuk LE; Zhao Q; Wang Y; Li Y; Du H; Sawant A
    Med Phys; 2007 Jan; 34(1):315-27. PubMed ID: 17278517
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.