These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

605 related articles for article (PubMed ID: 19243265)

  • 21. Alarm characterization for a continuous glucose monitor that replaces traditional blood glucose monitoring.
    McGarraugh G
    J Diabetes Sci Technol; 2010 Jan; 4(1):49-56. PubMed ID: 20167167
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Retrofitting Real-Life Dexcom G5 Data.
    Favero SD; Facchinetti A; Sparacino G; Cobelli C
    Diabetes Technol Ther; 2017 Apr; 19(4):237-245. PubMed ID: 28287834
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm.
    Bailey TS; Chang A; Christiansen M
    J Diabetes Sci Technol; 2015 Mar; 9(2):209-14. PubMed ID: 25370149
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes.
    Wadwa RP; Laffel LM; Shah VN; Garg SK
    Diabetes Technol Ther; 2018 Jun; 20(6):395-402. PubMed ID: 29901421
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Continuous glucose monitoring in subcutaneous tissue using factory-calibrated sensors: a pilot study.
    Hoss U; Jeddi I; Schulz M; Budiman E; Bhogal C; McGarraugh G
    Diabetes Technol Ther; 2010 Aug; 12(8):591-7. PubMed ID: 20615099
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel.
    Freckmann G; Pleus S; Link M; Zschornack E; Klötzer HM; Haug C
    J Diabetes Sci Technol; 2013 Jul; 7(4):842-53. PubMed ID: 23911165
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.
    Christiansen MP; Klaff LJ; Brazg R; Chang AR; Levy CJ; Lam D; Denham DS; Atiee G; Bode BW; Walters SJ; Kelley L; Bailey TS
    Diabetes Technol Ther; 2018 Mar; 20(3):197-206. PubMed ID: 29381090
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Accuracy evaluation of contour next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting.
    Klaff LJ; Brazg R; Hughes K; Tideman AM; Schachner HC; Stenger P; Pardo S; Dunne N; Parkes JL
    Diabetes Technol Ther; 2015 Jan; 17(1):8-15. PubMed ID: 25260047
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reduction in duration of hypoglycemia by automatic suspension of insulin delivery: the in-clinic ASPIRE study.
    Garg S; Brazg RL; Bailey TS; Buckingham BA; Slover RH; Klonoff DC; Shin J; Welsh JB; Kaufman FR
    Diabetes Technol Ther; 2012 Mar; 14(3):205-9. PubMed ID: 22316089
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparing the accuracy of transcutaneous sensor and 90-day implantable glucose sensor.
    Boscari F; Vettoretti M; Amato AML; Vallone V; Uliana A; Iori E; Avogaro A; Facchinetti A; Bruttomesso D
    Nutr Metab Cardiovasc Dis; 2021 Feb; 31(2):650-657. PubMed ID: 33594987
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial.
    Garg S; Zisser H; Schwartz S; Bailey T; Kaplan R; Ellis S; Jovanovic L
    Diabetes Care; 2006 Jan; 29(1):44-50. PubMed ID: 16373894
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy of a CGM Sensor in Pediatric Subjects With Type 1 Diabetes. Comparison of Three Insertion Sites: Arm, Abdomen, and Gluteus.
    Faccioli S; Del Favero S; Visentin R; Bonfanti R; Iafusco D; Rabbone I; Marigliano M; Schiaffini R; Bruttomesso D; Cobelli C;
    J Diabetes Sci Technol; 2017 Nov; 11(6):1147-1154. PubMed ID: 28486841
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy of Continuous Glucose Monitoring During Three Closed-Loop Home Studies Under Free-Living Conditions.
    Thabit H; Leelarathna L; Wilinska ME; Elleri D; Allen JM; Lubina-Solomon A; Walkinshaw E; Stadler M; Choudhary P; Mader JK; Dellweg S; Benesch C; Pieber TR; Arnolds S; Heller SR; Amiel SA; Dunger D; Evans ML; Hovorka R
    Diabetes Technol Ther; 2015 Nov; 17(11):801-7. PubMed ID: 26241693
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Accuracy and reliability of continuous glucose monitoring systems: a head-to-head comparison.
    Luijf YM; Mader JK; Doll W; Pieber T; Farret A; Place J; Renard E; Bruttomesso D; Filippi A; Avogaro A; Arnolds S; Benesch C; Heinemann L; DeVries JH;
    Diabetes Technol Ther; 2013 Aug; 15(8):722-7. PubMed ID: 23650900
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Influence of time point of calibration on accuracy of continuous glucose monitoring in individuals with type 1 diabetes.
    Zueger T; Diem P; Mougiakakou S; Stettler C
    Diabetes Technol Ther; 2012 Jul; 14(7):583-8. PubMed ID: 22512266
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Performance of a Factory-Calibrated Real-Time Continuous Glucose Monitoring System Utilizing an Automated Sensor Applicator.
    Shah VN; Laffel LM; Wadwa RP; Garg SK
    Diabetes Technol Ther; 2018 Jun; 20(6):428-433. PubMed ID: 29923775
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor.
    Bailey TS; Ahmann A; Brazg R; Christiansen M; Garg S; Watkins E; Welsh JB; Lee SW
    Diabetes Technol Ther; 2014 May; 16(5):277-83. PubMed ID: 24758729
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Performance of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System in Pediatric Participants With Type 1 Diabetes.
    Welsh JB; Zhang X; Puhr SA; Johnson TK; Walker TC; Balo AK; Price D
    J Diabetes Sci Technol; 2019 Mar; 13(2):254-258. PubMed ID: 30198331
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparative effectiveness analysis of three continuous glucose monitors.
    Damiano ER; El-Khatib FH; Zheng H; Nathan DM; Russell SJ
    Diabetes Care; 2013 Feb; 36(2):251-9. PubMed ID: 23275350
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Performance of the Dexcom G6 Continuous Glucose Monitoring System in Pregnant Women with Diabetes.
    Castorino K; Polsky S; O'Malley G; Levister C; Nelson K; Farfan C; Brackett S; Puhr S; Levy CJ
    Diabetes Technol Ther; 2020 Dec; 22(12):943-947. PubMed ID: 32324061
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 31.