BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 19247185)

  • 1. Increased reporting of detectable plasma HIV-1 RNA levels at the critical threshold of 50 copies per milliliter with the Taqman assay in comparison to the Amplicor assay.
    Lima V; Harrigan R; Montaner JS
    J Acquir Immune Defic Syndr; 2009 May; 51(1):3-6. PubMed ID: 19247185
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Concordance of HIV-1 RNA Values by Amplicor and TaqMan 2.0 in Patients With Confirmed Suppression in Clinical Trials.
    Garner W; White K; Szwarcberg J; McCallister S; Zhong L; Wulfsohn M
    Clin Infect Dis; 2016 Apr; 62(7):929-934. PubMed ID: 26689956
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative evaluation of the Cobas Amplicor HIV-1 Monitor Ultrasensitive Test, the new Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test and the Versant HIV RNA 3.0 assays for quantitation of HIV-1 RNA in plasma samples.
    Berger A; Scherzed L; Stürmer M; Preiser W; Doerr HW; Rabenau HF
    J Clin Virol; 2005 May; 33(1):43-51. PubMed ID: 15797364
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The significance of low-level plasma HIV viral load on COBAS TaqMan HIV-1 assays for patients with undetectable plasma viral load on COBAS Amplicor monitor version 1.5.
    Manavi K
    HIV Clin Trials; 2008; 9(4):283-6. PubMed ID: 18753122
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved Performance of COBAS AmpliPrep/COBAS TaqMan Version 2.0 Assay Over Amplicor Monitor Version 1.5 in the Quantification of HIV-1 RNA Viral Load in Abuja, Nigeria.
    Abubakar A; Ndembi N; Ogbanufe O; Inalegwu A; Wilson S; Ebagua I; Peters S; Chime C; Dakum P; Abimiku AG
    Curr HIV Res; 2015; 13(4):262-7. PubMed ID: 25613132
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ability of two commercially available assays (Abbott RealTime HIV-1 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2.0) to quantify low HIV-1 RNA Levels (<1,000 copies/milliliter): comparison with clinical samples and NIBSC working reagent for nucleic acid testing assays.
    Amendola A; Marsella P; Bloisi M; Forbici F; Angeletti C; Capobianchi MR
    J Clin Microbiol; 2014 Jun; 52(6):2019-26. PubMed ID: 24671791
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Three Different FDA-Approved Plasma HIV-1 RNA Assay Platforms Confirms the Virologic Failure Endpoint of 200 Copies per Milliliter Despite Improved Assay Sensitivity.
    Lalama CM; Jennings C; Johnson VA; Coombs RW; McKinnon JE; Bremer JW; Cobb BR; Cloherty GA; Mellors JW; Ribaudo HJ;
    J Clin Microbiol; 2015 Aug; 53(8):2659-66. PubMed ID: 26063861
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A modified ultrasensitive assay to detect quantified HIV-1 RNA of fewer than 50 copies per milliliter.
    Piwowar-Manning EM; Henderson TA; Brisbin L; Jackson JB
    Am J Clin Pathol; 2003 Aug; 120(2):268-70. PubMed ID: 12931558
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Detection of low HIV-1 RNA levels in plasma.
    Schockmel GA; Yerly S; Perrin L
    J Acquir Immune Defic Syndr Hum Retrovirol; 1997 Feb; 14(2):179-83. PubMed ID: 9052729
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cobas ampliprep/cobas TaqMan HIV-1 v2.0 assay: consequences at the cohort level.
    Taylor N; Grabmeier-Pfistershammer K; Egle A; Greil R; Rieger A; Ledergerber B; Oberkofler H
    PLoS One; 2013; 8(8):e74024. PubMed ID: 24023696
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Low-level viremia associated with the use of TaqMan assay.
    Szabo S; Moffett LE; Cantwell-McNelis K; James CW; Joseph A
    J Int Assoc Physicians AIDS Care (Chic); 2010; 9(4):203-5. PubMed ID: 20530465
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Utilities and limitations of a real-time PCR based assay for HIV-1 RNA quantification].
    Yotsumoto M; Yamamoto Y; Amano K; Fukutake K
    Rinsho Byori; 2010 Feb; 58(2):124-30. PubMed ID: 20229810
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test: comparison with the Cobas Amplicor HIV-1 Monitor test (manual specimen preparation).
    Berger A; Scherzed L; Stürmer M; Preiser W; Doerr HW; Rabenau HF
    J Clin Virol; 2002 Dec; 25 Suppl 3():S103-7. PubMed ID: 12467784
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Viral load assay sensitivity and low level viremia in HAART treated HIV patients.
    Verhofstede C; Van Wanzeele F; Reynaerts J; Mangelschots M; Plum J; Fransen K
    J Clin Virol; 2010 Apr; 47(4):335-9. PubMed ID: 20138803
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimation of measurement error in plasma HIV-1 RNA assays near their limit of quantification.
    Lima VD; Wang L; Brumme C; Wu L; Montaner JS; Harrigan PR
    PLoS One; 2017; 12(2):e0171155. PubMed ID: 28152073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test and identification of rare polymorphisms potentially affecting assay performance.
    Pyne MT; Brown KL; Hillyard DR
    J Clin Microbiol; 2010 Aug; 48(8):2852-8. PubMed ID: 20573864
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative RNA quantification of HIV-1 group M and non-M with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 v2.0 and Abbott Real-Time HIV-1 PCR assays.
    Sire JM; Vray M; Merzouk M; Plantier JC; Pavie J; Maylin S; Timsit J; Lascoux-Combe C; Molina JM; Simon F; Delaugerre C
    J Acquir Immune Defic Syndr; 2011 Mar; 56(3):239-43. PubMed ID: 21164353
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots.
    Maritz J; Preiser W; van Zyl GU
    J Clin Virol; 2012 Feb; 53(2):106-9. PubMed ID: 22196872
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fully automated quantification of human immunodeficiency virus (HIV) type 1 RNA in human plasma by the COBAS AmpliPrep/COBAS TaqMan system.
    Schumacher W; Frick E; Kauselmann M; Maier-Hoyle V; van der Vliet R; Babiel R
    J Clin Virol; 2007 Apr; 38(4):304-12. PubMed ID: 17329164
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes.
    Karasi JC; Dziezuk F; Quennery L; Förster S; Reischl U; Colucci G; Schoener D; Seguin-Devaux C; Schmit JC
    J Clin Virol; 2011 Nov; 52(3):181-6. PubMed ID: 21813320
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.