BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

352 related articles for article (PubMed ID: 19261785)

  • 21. Multiplex PCR of sonication fluid accurately differentiates between prosthetic joint infection and aseptic failure.
    Portillo ME; Salvadó M; Sorli L; Alier A; Martínez S; Trampuz A; Gómez J; Puig L; Horcajada JP
    J Infect; 2012 Dec; 65(6):541-8. PubMed ID: 22960370
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Implant sonication for the diagnosis of prosthetic elbow infection.
    Vergidis P; Greenwood-Quaintance KE; Sanchez-Sotelo J; Morrey BF; Steinmann SP; Karau MJ; Osmon DR; Mandrekar JN; Steckelberg JM; Patel R
    J Shoulder Elbow Surg; 2011 Dec; 20(8):1275-81. PubMed ID: 22078323
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Sonication of removed implants improves microbiological diagnosis of postoperative spinal infections.
    Bürger J; Akgün D; Strube P; Putzier M; Pumberger M
    Eur Spine J; 2019 Apr; 28(4):768-774. PubMed ID: 30656472
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparative study of cultures and next-generation sequencing in the diagnosis of shoulder prosthetic joint infections.
    Namdari S; Nicholson T; Abboud J; Lazarus M; Ramsey ML; Williams G; Parvizi J
    J Shoulder Elbow Surg; 2019 Jan; 28(1):1-8. PubMed ID: 30551780
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Detection of bacteria with molecular methods in prosthetic joint infection: sonication fluid better than periprosthetic tissue.
    Rak M; KavčIč M; Trebše R; CőR A
    Acta Orthop; 2016 Aug; 87(4):339-45. PubMed ID: 27123818
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Escherichia coli variants in periprosthetic joint infection: diagnostic challenges with sessile bacteria and sonication.
    Sendi P; Frei R; Maurer TB; Trampuz A; Zimmerli W; Graber P
    J Clin Microbiol; 2010 May; 48(5):1720-5. PubMed ID: 20335421
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Combination of conventional culture, vial culture, and broad-range PCR of sonication fluid for the diagnosis of prosthetic joint infection.
    Stylianakis A; Schinas G; Thomaidis PC; Papaparaskevas J; Ziogas DC; Gamaletsou MN; Daikos GL; Pneumaticos S; Sipsas NV
    Diagn Microbiol Infect Dis; 2018 Sep; 92(1):13-18. PubMed ID: 30099992
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Accuracy of different diagnostic tests for early, delayed and late prosthetic joint infection.
    Fernández-Sampedro M; Fariñas-Alvarez C; Garces-Zarzalejo C; Alonso-Aguirre MA; Salas-Venero C; Martínez-Martínez L; Fariñas MC
    BMC Infect Dis; 2017 Aug; 17(1):592. PubMed ID: 28841913
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Implant sonication versus intraoperative tissue sample cultures for Periprosthetic Joint Infection (PJI) of Shoulder Arthroplasty.
    Padolino A; Cataldo G; Tarallo L; Fabbri E; Merolla G; Micheloni GM; Paladini P; Porcellini G
    Acta Biomed; 2021 Jul; 92(S3):e2021009. PubMed ID: 34313671
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Hemolytic strains of Propionibacterium acnes do not demonstrate greater pathogenicity in periprosthetic shoulder infections.
    Mahylis JM; Entezari V; Karichu J; Richter S; Derwin KA; Iannotti JP; Ricchetti ET
    J Shoulder Elbow Surg; 2018 Jun; 27(6):1097-1104. PubMed ID: 29472140
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of the CosmosID Bioinformatics Platform for Prosthetic Joint-Associated Sonicate Fluid Shotgun Metagenomic Data Analysis.
    Yan Q; Wi YM; Thoendel MJ; Raval YS; Greenwood-Quaintance KE; Abdel MP; Jeraldo PR; Chia N; Patel R
    J Clin Microbiol; 2019 Feb; 57(2):. PubMed ID: 30429253
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Sonication of Extracted Implants Improves Microbial Detection in Patients With Orthopedic Implant-Associated Infections.
    Ueda N; Oe K; Nakamura T; Tsuta K; Iida H; Saito T
    J Arthroplasty; 2019 Jun; 34(6):1189-1196. PubMed ID: 30872034
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A comprehensive microbiological evaluation of fifty-four patients undergoing revision surgery due to prosthetic joint loosening.
    Bjerkan G; Witsø E; Nor A; Viset T; Løseth K; Lydersen S; Persen L; Bergh K
    J Med Microbiol; 2012 Apr; 61(Pt 4):572-581. PubMed ID: 22135023
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of the use of sonication of retrieved implants for the diagnosis of prosthetic joint infection in a routine setting.
    Prieto-Borja L; Auñón Á; Blanco A; Fernández-Roblas R; Gadea I; García-Cañete J; Parrón R; Esteban J
    Eur J Clin Microbiol Infect Dis; 2018 Apr; 37(4):715-722. PubMed ID: 29270861
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Molecular Diagnosis of Orthopedic-Device-Related Infection Directly from Sonication Fluid by Metagenomic Sequencing.
    Street TL; Sanderson ND; Atkins BL; Brent AJ; Cole K; Foster D; McNally MA; Oakley S; Peto L; Taylor A; Peto TEA; Crook DW; Eyre DW
    J Clin Microbiol; 2017 Aug; 55(8):2334-2347. PubMed ID: 28490492
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Poor utility of serum interleukin-6 levels to predict indolent periprosthetic shoulder infections.
    Grosso MJ; Frangiamore SJ; Saleh A; Kovac MF; Hayashi R; Ricchetti ET; Bauer TW; Iannotti JP
    J Shoulder Elbow Surg; 2014 Sep; 23(9):1277-81. PubMed ID: 24725902
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of sonicate fluid cultures in comparison to histological analysis of the periprosthetic membrane for the detection of periprosthetic joint infection.
    Janz V; Wassilew GI; Hasart O; Matziolis G; Tohtz S; Perka C
    Int Orthop; 2013 May; 37(5):931-6. PubMed ID: 23525549
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Diagnostic Arthroscopy for Detection of Periprosthetic Infection in Painful Shoulder Arthroplasty.
    Akgün D; Maziak N; Plachel F; Minkus M; Scheibel M; Perka C; Moroder P
    Arthroscopy; 2019 Sep; 35(9):2571-2577. PubMed ID: 31351811
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Antimicrobial-Loaded Bone Cement Does Not Negatively Influence Sonicate Fluid Culture Positivity for Diagnosis of Prosthetic Joint Infection.
    Park KH; Greenwood-Quaintance KE; Hanssen AD; Abdel MP; Patel R
    J Clin Microbiol; 2016 Jun; 54(6):1656-1659. PubMed ID: 27030490
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Sonication versus Tissue Sampling for Diagnosis of Prosthetic Joint and Other Orthopedic Device-Related Infections.
    Dudareva M; Barrett L; Figtree M; Scarborough M; Watanabe M; Newnham R; Wallis R; Oakley S; Kendrick B; Stubbs D; McNally MA; Bejon P; Atkins BA; Taylor A; Brent AJ
    J Clin Microbiol; 2018 Dec; 56(12):. PubMed ID: 30209185
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.