322 related articles for article (PubMed ID: 19268861)
1. Digital bowel cleansing free colonic polyp detection method for fecal tagging CT colonography.
Oda M; Kitasaka T; Mori K; Suenaga Y; Takayama T; Takabatake H; Mori M; Natori H; Nawano S
Acad Radiol; 2009 Apr; 16(4):486-94. PubMed ID: 19268861
[TBL] [Abstract][Full Text] [Related]
2. Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography.
Suzuki K; Yoshida H; Näppi J; Armato SG; Dachman AH
Med Phys; 2008 Feb; 35(2):694-703. PubMed ID: 18383691
[TBL] [Abstract][Full Text] [Related]
3. Computer-aided detection of colonic polyps at CT colonography using a Hessian matrix-based algorithm: preliminary study.
Kim SH; Lee JM; Lee JG; Kim JH; Lefere PA; Han JK; Choi BI
AJR Am J Roentgenol; 2007 Jul; 189(1):41-51. PubMed ID: 17579150
[TBL] [Abstract][Full Text] [Related]
4. Fully automated three-dimensional detection of polyps in fecal-tagging CT colonography.
Näppi J; Yoshida H
Acad Radiol; 2007 Mar; 14(3):287-300. PubMed ID: 17307661
[TBL] [Abstract][Full Text] [Related]
5. Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection.
Linguraru MG; Panjwani N; Fletcher JG; Summers RM
Med Phys; 2011 Dec; 38(12):6633-42. PubMed ID: 22149845
[TBL] [Abstract][Full Text] [Related]
6. Colonic polyp segmentation in CT colonography-based on fuzzy clustering and deformable models.
Yao J; Miller M; Franaszek M; Summers RM
IEEE Trans Med Imaging; 2004 Nov; 23(11):1344-52. PubMed ID: 15554123
[TBL] [Abstract][Full Text] [Related]
7. Detection of protrusions in curved folded surfaces applied to automated polyp detection in CT colonography.
van Wijk C; van Ravesteijn VF; Vos FM; Truyen R; de Vries AH; Stoker J; van Vliet LJ
Med Image Comput Comput Assist Interv; 2006; 9(Pt 2):471-8. PubMed ID: 17354806
[TBL] [Abstract][Full Text] [Related]
8. CT colonography: automated measurement of colonic polyps compared with manual techniques--human in vitro study.
Taylor SA; Slater A; Halligan S; Honeyfield L; Roddie ME; Demeshski J; Amin H; Burling D
Radiology; 2007 Jan; 242(1):120-8. PubMed ID: 17105850
[TBL] [Abstract][Full Text] [Related]
9. Automatic colon polyp flagging via geometric and texture features.
Fiori M; Musé P; Aguirre S; Sapiro G
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3170-3. PubMed ID: 21096596
[TBL] [Abstract][Full Text] [Related]
10. Computer-aided detection of colorectal polyps in CT colonography with and without fecal tagging: a stand-alone evaluation.
Mang T; Bogoni L; Salganicoff M; Wolf M; Raykar V; Macari M; Pickhardt PJ; Iafrate F; Laghi A; Weber M; Baker ME; Ringl H; Herold CJ; Graser A
Invest Radiol; 2012 Feb; 47(2):99-108. PubMed ID: 21934519
[TBL] [Abstract][Full Text] [Related]
11. Shape filtering for false positive reduction at computed tomography colonography.
Miranda AA; Chowdhury TA; Ghita O; Whelan PF
Med Image Comput Comput Assist Interv; 2006; 9(Pt 2):84-92. PubMed ID: 17354759
[TBL] [Abstract][Full Text] [Related]
12. Symmetric curvature patterns for colonic polyp detection.
Jerebko A; Lakare S; Cathier P; Periaswamy S; Bogoni L
Med Image Comput Comput Assist Interv; 2006; 9(Pt 2):169-76. PubMed ID: 17354769
[TBL] [Abstract][Full Text] [Related]
13. Performance of a previously validated CT colonography computer-aided detection system in a new patient population.
Summers RM; Handwerker LR; Pickhardt PJ; Van Uitert RL; Deshpande KK; Yeshwant S; Yao J; Franaszek M
AJR Am J Roentgenol; 2008 Jul; 191(1):168-74. PubMed ID: 18562741
[TBL] [Abstract][Full Text] [Related]
14. Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps.
Yoshida H; Näppi J
IEEE Trans Med Imaging; 2001 Dec; 20(12):1261-74. PubMed ID: 11811826
[TBL] [Abstract][Full Text] [Related]
15. A pipeline for computer aided polyp detection.
Hong W; Qiu F; Kaufman A
IEEE Trans Vis Comput Graph; 2006; 12(5):861-8. PubMed ID: 17080810
[TBL] [Abstract][Full Text] [Related]
16. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study.
Li P; Napel S; Acar B; Paik DS; Jeffrey RB; Beaulieu CF
Med Phys; 2004 Oct; 31(10):2912-23. PubMed ID: 15543800
[TBL] [Abstract][Full Text] [Related]
17. Computerized detection of colorectal masses in CT colonography based on fuzzy merging and wall-thickening analysis.
Näppi JJ; Frimmel H; Dachman AH; Yoshida H
Med Phys; 2004 Apr; 31(4):860-72. PubMed ID: 15125004
[TBL] [Abstract][Full Text] [Related]
18. Influence of computer-aided detection false-positives on reader performance and diagnostic confidence for CT colonography.
Taylor SA; Brittenden J; Lenton J; Lambie H; Goldstone A; Wylie PN; Tolan D; Burling D; Honeyfield L; Bassett P; Halligan S
AJR Am J Roentgenol; 2009 Jun; 192(6):1682-9. PubMed ID: 19457835
[TBL] [Abstract][Full Text] [Related]
19. A CAD of fully automated colonic polyp detection for contrasted and non-contrasted CT scans.
Tulum G; Bolat B; Osman O
Int J Comput Assist Radiol Surg; 2017 Apr; 12(4):627-644. PubMed ID: 28101760
[TBL] [Abstract][Full Text] [Related]
20. Optimizing computer-aided colonic polyp detection for CT colonography by evolving the Pareto fronta.
Li J; Huang A; Yao J; Liu J; Van Uitert RL; Petrick N; Summers RM
Med Phys; 2009 Jan; 36(1):201-12. PubMed ID: 19235388
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]