BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

278 related articles for article (PubMed ID: 19282557)

  • 1. Non-invasive estimation of pulsatile flow and differential pressure in an implantable rotary blood pump for heart failure patients.
    AlOmari AH; Savkin AV; Karantonis DM; Lim E; Lovell NH
    Physiol Meas; 2009 Apr; 30(4):371-86. PubMed ID: 19282557
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.
    Malagutti N; Karantonis DM; Cloherty SL; Ayre PJ; Mason DG; Salamonsen RF; Lovell NH
    Artif Organs; 2007 Jan; 31(1):45-52. PubMed ID: 17209960
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noninvasive average flow and differential pressure estimation for an implantable rotary blood pump using dimensional analysis.
    Lim E; Karantonis DM; Reizes JA; Cloherty SL; Mason DG; Lovell NH
    IEEE Trans Biomed Eng; 2008 Aug; 55(8):2094-101. PubMed ID: 18632372
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Non-invasive estimation and control of inlet pressure in an implantable rotary blood pump for heart failure patients.
    Alomari AH; Savkin AV; Ayre PJ; Lim E; Mason DG; Salamonsen RF; Fraser JF; Lovell NH
    Physiol Meas; 2011 Aug; 32(8):1035-60. PubMed ID: 21666292
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A method for control of an implantable rotary blood pump for heart failure patients using noninvasive measurements.
    Lim E; Alomari AH; Savkin AV; Dokos S; Fraser JF; Timms DL; Mason DG; Lovell NH
    Artif Organs; 2011 Aug; 35(8):E174-80. PubMed ID: 21843286
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vivo validation of pulsatile flow and differential pressure estimation models in a left ventricular assist device.
    Zhang XT; Alomari AH; Savkin AV; Ayre PJ; Lim E; Salamonsen RF; Rosenfeldt FL; Lovell NH
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():2517-20. PubMed ID: 21096435
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of left ventricular assist device performance and hydraulic force in a complete mock circulation loop.
    Timms D; Hayne M; Tan A; Pearcy M
    Artif Organs; 2005 Jul; 29(7):573-80. PubMed ID: 15982286
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A hemodynamic evaluation of the Medos Deltastream DP1 rotary pump and Jostra HL-20 roller pump under pulsatile and nonpulsatile perfusion in an infant cardiopulmonary bypass model--a pilot study.
    Rider AR; Griffith K; Ressler N; Kunselman AR; Wang S; Undar A
    ASAIO J; 2008; 54(5):529-33. PubMed ID: 18812747
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The heart-Hemopump interaction: a study of Hemopump flow as a function of cardiac activity.
    Meyns B; Siess T; Laycock S; Reul H; Rau G; Flameng W
    Artif Organs; 1996 Jun; 20(6):641-9. PubMed ID: 8817971
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Noninvasive pulsatile flow estimation for an implantable rotary blood pump.
    Karantonis DM; Cloherty SL; Mason DG; Ayre PJ; Lovell NH
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1018-21. PubMed ID: 18002133
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Adaptive physiological speed/flow control of rotary blood pumps in permanent implantation using intrinsic pump parameters.
    Wu Y
    ASAIO J; 2009; 55(4):335-9. PubMed ID: 19506462
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Control system for an implantable rotary blood pump.
    Nakata KI; Yoshikawa M; Takano T; Sankai Y; Ohtsuka G; Glueck J; Fujisawa A; Makinouchi K; Yokokawa M; Nosaka S; Nose Y
    Ann Thorac Cardiovasc Surg; 2000 Aug; 6(4):242-6. PubMed ID: 11042480
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a pump flow estimator for rotary blood pumps to enhance monitoring of ventricular function.
    Granegger M; Moscato F; Casas F; Wieselthaler G; Schima H
    Artif Organs; 2012 Aug; 36(8):691-9. PubMed ID: 22882439
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-invasive flow estimation in an implantable rotary blood pump: a study considering non-pulsatile and pulsatile flows.
    Ayre PJ; Lovell NH; Woodard JC
    Physiol Meas; 2003 Feb; 24(1):179-89. PubMed ID: 12636195
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Establishment of flow estimation for an implantable centrifugal blood pump.
    Wakisaka Y; Okuzono Y; Taenaka Y; Chikanari K; Masuzawa T; Takano H
    ASAIO J; 1997; 43(5):M659-62. PubMed ID: 9360128
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of pulsatility on the mathematical modeling of rotary blood pumps.
    Pirbodaghi T; Weber A; Carrel T; Vandenberghe S
    Artif Organs; 2011 Aug; 35(8):825-32. PubMed ID: 21793862
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dynamic modeling of the outlet of a pulsatile pump incorporating a flow-dependent resistance.
    Huang H; Yang M; Wu S; Liao H
    Med Eng Phys; 2013 Aug; 35(8):1097-104. PubMed ID: 23253954
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of parameter variations on the hemodynamic response under rotary blood pump assistance.
    Lim E; Dokos S; Salamonsen RF; Rosenfeldt FL; Ayre PJ; Lovell NH
    Artif Organs; 2012 May; 36(5):E125-37. PubMed ID: 22489771
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Physiological control of blood pumps using intrinsic pump parameters: a computer simulation study.
    Giridharan GA; Skliar M
    Artif Organs; 2006 Apr; 30(4):301-7. PubMed ID: 16643388
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement for implantable rotary blood pumps.
    Bertram CD
    Physiol Meas; 2005 Aug; 26(4):R99-117. PubMed ID: 15886429
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.