  • 1. A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode.
    Ishikawa M; Bengua G; Sutherland KL; Hiratsuka J; Katoh N; Shimizu S; Aoyama H; Fujita K; Yamazaki R; Horita K; Shirato H
    Phys Med Biol; 2009 Apr; 54(7):2079-92. PubMed ID: 19287089
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A plastic scintillation dosimeter for high dose rate brachytherapy.
    Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
    Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
    Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
    Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.
    Ishikawa M; Nagase N; Matsuura T; Hiratsuka J; Suzuki R; Miyamoto N; Sutherland KL; Fujita K; Shirato H
    J Radiat Res; 2015 Mar; 56(2):372-81. PubMed ID: 25618136
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
    Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
    Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Scintillation dosimeter arrays using air core light guides: simulation and experiment.
    Naseri P; Suchowerska N; McKenzie DR
    Phys Med Biol; 2010 Jun; 55(12):3401-15. PubMed ID: 20505222
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
    Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The determination of beam quality correction factors: Monte Carlo simulations and measurements.
    González-Castaño DM; Hartmann GH; Sánchez-Doblado F; Gómez F; Kapsch RP; Pena J; Capote R
    Phys Med Biol; 2009 Aug; 54(15):4723-41. PubMed ID: 19622853
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The angular dependence and effective point of measurement of a cylindrical scintillation dosimeter with and without a radio-opaque marker for brachytherapy.
    Cartwright LE; Lambert J; McKenzie DR; Suchowerska N
    Phys Med Biol; 2009 Apr; 54(7):2217-27. PubMed ID: 19293468
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CALCULATION OF GAMMA SPECTRA IN A PLASTIC SCINTILLATOR FOR ENERGY CALIBRATIONAND DOSE COMPUTATION.
    Kim C; Yoo H; Kim Y; Moon M; Kim JY; Kang DU; Lee D; Kim MS; Cho M; Lee E; Cho G
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):377-81. PubMed ID: 27127208
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry.
    Geso M; Robinson N; Schumer W; Williams K
    Australas Phys Eng Sci Med; 2004 Mar; 27(1):5-10. PubMed ID: 15156701
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Towards two-dimensional brachytherapy dosimetry using plastic scintillator: new highly efficient water equivalent plastic scintillator materials.
    Kirov AS; Hurlbut C; Dempsey JF; Shrinivas SB; Epstein JW; Binns WR; Dowkontt PF; Williamson JF
    Med Phys; 1999 Aug; 26(8):1515-23. PubMed ID: 10501051
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Water equivalent phantom materials for ¹⁹²Ir brachytherapy.
    Schoenfeld AA; Harder D; Poppe B; Chofor N
    Phys Med Biol; 2015 Dec; 60(24):9403-20. PubMed ID: 26579946
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry.
    Jang KW; Yagi T; Pyeon CH; Yoo WJ; Shin SH; Jeong C; Min BJ; Shin D; Misawa T; Lee B
    J Biomed Opt; 2013 Feb; 18(2):27001. PubMed ID: 23377008
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.
    Beddar AS; Briere TM; Mourtada FA; Vassiliev ON; Liu HH; Mohan R
    Med Phys; 2005 May; 32(5):1265-9. PubMed ID: 15984678
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of H'(0.07) using the plastic scintillation pulse height weighting integration method.
    Li-ye L; Ji-zeng M
    Radiat Prot Dosimetry; 2004; 112(3):371-6. PubMed ID: 15494362
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Streak camera measurement of subnanosecond plastic scintillator properties.
    Cheng JC; Tirsell KG; Tripp GR; Lent EM; Lerche RA
    Rev Sci Instrum; 1978 May; 49(5):650. PubMed ID: 18699166
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer--a phantom study.
    Anton M; Wagner D; Selbach HJ; Hackel T; Hermann RM; Hess CF; Vorwerk H
    Phys Med Biol; 2009 May; 54(9):2915-31. PubMed ID: 19384000
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Small field dose measurements using plastic scintillation detector in heterogeneous media.
    Xue J; McKay JD; Grimm J; Cheng CW; Berg R; Grimm SL; Xu Q; Subedi G; Das IJ
    Med Phys; 2017 Jul; 44(7):3815-3820. PubMed ID: 28398596
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurements of relative depth doses and Cerenkov light using a scintillating fiber-optic dosimeter with Co-60 radiotherapy source.
    Jang KW; Yoo WJ; Moon J; Han KT; Park JY; Lee B
    Appl Radiat Isot; 2012 Jan; 70(1):274-7. PubMed ID: 21889353
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]