256 related articles for article (PubMed ID: 19289400)
21. Diagnostic reference levels and effective dose in paediatric cardiac catheterization.
Onnasch DG; Schröder FK; Fischer G; Kramer HH
Br J Radiol; 2007 Mar; 80(951):177-85. PubMed ID: 16916806
[TBL] [Abstract][Full Text] [Related]
22. 2007 recommendations of the ICRP change basis for estimation of the effective dose: what is the impact on radiation dose assessment of patient and personnel?
Boetticher Hv; Lachmund J; Looe HK; Hoffmann W; Poppe B
Rofo; 2008 May; 180(5):391-5. PubMed ID: 18438741
[TBL] [Abstract][Full Text] [Related]
23. An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures.
Morrish OW; Goldstone KE
Br J Radiol; 2008 Jan; 81(961):35-45. PubMed ID: 18039722
[TBL] [Abstract][Full Text] [Related]
24. Automatic exposure control in pediatric and adult computed tomography examinations: can we estimate organ and effective dose from mean MAS reduction?
Papadakis AE; Perisinakis K; Oikonomou I; Damilakis J
Invest Radiol; 2011 Oct; 46(10):654-62. PubMed ID: 21673583
[TBL] [Abstract][Full Text] [Related]
25. Radiation doses in paediatric interventional cardiology procedures.
Tsapaki V; Kottou S; Korniotis S; Nikolaki N; Rammos S; Apostolopoulou SC
Radiat Prot Dosimetry; 2008; 132(4):390-4. PubMed ID: 19122002
[TBL] [Abstract][Full Text] [Related]
26. Assessment of organ radiation dose associated with uterine artery embolization.
Glomset O; Hellesnes J; Heimland N; Hafsahl G; Smith HJ
Acta Radiol; 2006 Mar; 47(2):179-85. PubMed ID: 16604965
[TBL] [Abstract][Full Text] [Related]
27. [Variations of radiation dosage delivered to patients undergoing interventional cardiological procedures. A monocentric study 2002-05].
Georges JL; Livarek B; Gibault-Genty G; Messaoudi H; Aziza JP; Hautecoeur JL; Soleille H
Arch Mal Coeur Vaiss; 2007 Mar; 100(3):175-81. PubMed ID: 17536420
[TBL] [Abstract][Full Text] [Related]
28. A study of the relationship between peak skin dose and cumulative air kerma in interventional neuroradiology and cardiology.
Neil S; Padgham C; Martin CJ
J Radiol Prot; 2010 Dec; 30(4):659-72. PubMed ID: 21149930
[TBL] [Abstract][Full Text] [Related]
29. A systematic review of conversion factors between kerma-area product and effective/organ dose for cardiac interventional fluoroscopy procedures performed in adult and paediatric patients.
Brambilla M; D'Alessio A; Kuchcinska A; Segota D; Sukupova L
Phys Med Biol; 2022 Mar; 67(6):. PubMed ID: 35176728
[TBL] [Abstract][Full Text] [Related]
30. DO THE BMI AND SURGEON INFLUENCE THE PATIENT DOSE IN FLUOROSCOPICALLY GUIDED LUMBAR DISCECTOMY AND FUSION?☆.
Metaxas VI; Messaris GA; Gatzounis GD; Tzortzidis FN; Panayiotakis GS
Radiat Prot Dosimetry; 2019 Dec; 185(4):472-482. PubMed ID: 30916774
[TBL] [Abstract][Full Text] [Related]
31. Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern?
Whitby M; Martin CJ
Br J Radiol; 2003 May; 76(905):321-7. PubMed ID: 12763947
[TBL] [Abstract][Full Text] [Related]
32. Reference levels and patient doses in interventional cardiology procedures in Greece.
Simantirakis G; Koukorava C; Kalathaki M; Pafilis C; Kaisas I; Economides S; Hourdakis CJ; Kamenopoulou V; Georgiou E
Eur Radiol; 2013 Aug; 23(8):2324-32. PubMed ID: 23559142
[TBL] [Abstract][Full Text] [Related]
33. Patient radiation doses in paediatric interventional cardiology procedures: a review.
Harbron RW; Dreuil S; Bernier MO; Pearce MS; Thierry-Chef I; Chapple CL; Baysson H
J Radiol Prot; 2016 Dec; 36(4):R131-R144. PubMed ID: 27893455
[TBL] [Abstract][Full Text] [Related]
34. Scatter and staff dose levels in paediatric interventional cardiology: a multicentre study.
Ubeda C; Vano E; Gonzalez L; Miranda P; Valenzuela E; Leyton F; Oyarzun C
Radiat Prot Dosimetry; 2010 Jun; 140(1):67-74. PubMed ID: 20159911
[TBL] [Abstract][Full Text] [Related]
35. Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation.
Ector J; Dragusin O; Adriaenssens B; Huybrechts W; Willems R; Ector H; Heidbüchel H
J Am Coll Cardiol; 2007 Jul; 50(3):234-42. PubMed ID: 17631216
[TBL] [Abstract][Full Text] [Related]
36. Radiation burden to paediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital.
Schultz FW; Geleijns J; Holscher HC; Weststrate J; Zonderland HM; Zoetelief J
Br J Radiol; 1999 Aug; 72(860):763-72. PubMed ID: 10624342
[TBL] [Abstract][Full Text] [Related]
37. A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment.
Bogaert E; Bacher K; Thierens H
Radiat Prot Dosimetry; 2008; 128(3):312-23. PubMed ID: 17681964
[TBL] [Abstract][Full Text] [Related]
38. Consideration of the ICRP 2006 revised tissue weighting factors on age-dependent values of the effective dose for external photons.
Lee C; Lee C; Han EY; Bolch WE
Phys Med Biol; 2007 Jan; 52(1):41-58. PubMed ID: 17183127
[TBL] [Abstract][Full Text] [Related]
39. Conversion factors to estimate effective doses from kerma area product in interventional cardiology. Impact of added filtration.
Vano E; Sánchez RM; Fernández JM; Ten JI
Phys Med; 2019 Dec; 68():104-111. PubMed ID: 31770685
[TBL] [Abstract][Full Text] [Related]
40. Radiation dose levels for interventional CT procedures.
Leng S; Christner JA; Carlson SK; Jacobsen M; Vrieze TJ; Atwell TD; McCollough CH
AJR Am J Roentgenol; 2011 Jul; 197(1):W97-103. PubMed ID: 21701002
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]