These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
236 related articles for article (PubMed ID: 19289401)
1. Simple methods to reduce patient dose in a Varian cone beam CT system for delivery verification in pelvic radiotherapy. Roxby P; Kron T; Foroudi F; Haworth A; Fox C; Mullen A; Cramb J Br J Radiol; 2009 Oct; 82(982):855-9. PubMed ID: 19289401 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of radiation dose and image quality for the Varian cone beam computed tomography system. Cheng HC; Wu VW; Liu ES; Kwong DL Int J Radiat Oncol Biol Phys; 2011 May; 80(1):291-300. PubMed ID: 20932676 [TBL] [Abstract][Full Text] [Related]
3. Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit. Cai B; Laugeman E; Mazur TR; Park JC; Henke LE; Kim H; Hugo GD; Mutic S; Li H Med Phys; 2019 Mar; 46(3):1355-1370. PubMed ID: 30675902 [TBL] [Abstract][Full Text] [Related]
4. Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments. Held M; Cremers F; Sneed PK; Braunstein S; Fogh SE; Nakamura J; Barani I; Perez-Andujar A; Pouliot J; Morin O J Appl Clin Med Phys; 2016 Mar; 17(2):279-290. PubMed ID: 27074487 [TBL] [Abstract][Full Text] [Related]
5. Dual-energy imaging method to improve the image quality and the accuracy of dose calculation for cone-beam computed tomography. Men K; Dai J; Chen X; Li M; Zhang K; Huang P Phys Med; 2017 Apr; 36():110-118. PubMed ID: 28410679 [TBL] [Abstract][Full Text] [Related]
6. A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept. Men K; Dai J Technol Cancer Res Treat; 2017 Dec; 16(6):1179-1186. PubMed ID: 29332447 [TBL] [Abstract][Full Text] [Related]
7. The impact of CBCT reconstruction and calibration for radiotherapy planning in the head and neck region - a phantom study. Elstrøm UV; Olsen SR; Muren LP; Petersen JB; Grau C Acta Oncol; 2014 Aug; 53(8):1114-24. PubMed ID: 24975372 [TBL] [Abstract][Full Text] [Related]
8. Low-dose megavoltage cone-beam CT for radiation therapy. Pouliot J; Bani-Hashemi A; Chen J; Svatos M; Ghelmansarai F; Mitschke M; Aubin M; Xia P; Morin O; Bucci K; Roach M; Hernandez P; Zheng Z; Hristov D; Verhey L Int J Radiat Oncol Biol Phys; 2005 Feb; 61(2):552-60. PubMed ID: 15736320 [TBL] [Abstract][Full Text] [Related]
9. Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study. Kim J; Keum KC; Lee H; Hong CS; Park K; Kim JS Radiat Oncol; 2020 Sep; 15(1):224. PubMed ID: 32977808 [TBL] [Abstract][Full Text] [Related]
10. Dose calculation accuracy of different image value to density tables for cone-beam CT planning in head & neck and pelvic localizations. Barateau A; Garlopeau C; Cugny A; De Figueiredo BH; Dupin C; Caron J; Antoine M Phys Med; 2015 Mar; 31(2):146-51. PubMed ID: 25595131 [TBL] [Abstract][Full Text] [Related]
11. Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems. Gardner SJ; Studenski MT; Giaddui T; Cui Y; Galvin J; Yu Y; Xiao Y Med Phys; 2014 Mar; 41(3):031908. PubMed ID: 24593726 [TBL] [Abstract][Full Text] [Related]
12. A comprehensive study on decreasing the kilovoltage cone-beam CT dose by reducing the projection number. Lu B; Lu H; Palta J J Appl Clin Med Phys; 2010 May; 11(3):3274. PubMed ID: 20717096 [TBL] [Abstract][Full Text] [Related]
13. Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance. Schafer S; Nithiananthan S; Mirota DJ; Uneri A; Stayman JW; Zbijewski W; Schmidgunst C; Kleinszig G; Khanna AJ; Siewerdsena JH Med Phys; 2011 Aug; 38(8):4563-74. PubMed ID: 21928628 [TBL] [Abstract][Full Text] [Related]
14. Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study. Yang CC; Chen FL; Lo YC PLoS One; 2016; 11(6):e0157072. PubMed ID: 27280593 [TBL] [Abstract][Full Text] [Related]
15. Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography. Trivedi G; Dixit CK; Oinam AS; Kapoor R; Bahl A J Cancer Res Ther; 2019; 15(3):470-474. PubMed ID: 31169206 [TBL] [Abstract][Full Text] [Related]
16. An evaluation of the stability of image-quality parameters of Varian on-board imaging (OBI) and EPID imaging systems. Stanley DN; Papanikolaou N; Gutierrez AN J Appl Clin Med Phys; 2015 Mar; 16(2):5088. PubMed ID: 26103178 [TBL] [Abstract][Full Text] [Related]
17. The effects of field-of-view and patient size on CT numbers from cone-beam computed tomography. Seet KY; Barghi A; Yartsev S; Van Dyk J Phys Med Biol; 2009 Oct; 54(20):6251-62. PubMed ID: 19794246 [TBL] [Abstract][Full Text] [Related]
18. [Analysis of image quality and dose calculation accuracy in cone beam CT acquisitions with limited projection data (half scan, half fan) with regard to usability for adaptive radiation therapy treatment planning]. Kowatsch M; Winkler P; Zurl B; Konrad T; Schröttner J Z Med Phys; 2011; 21(1):11-8. PubMed ID: 20888201 [TBL] [Abstract][Full Text] [Related]
19. Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition. Tomic N; Devic S; DeBlois F; Seuntjens J Med Phys; 2010 Mar; 37(3):1083-92. PubMed ID: 20384244 [TBL] [Abstract][Full Text] [Related]
20. Investigation of the usability of conebeam CT data sets for dose calculation. Richter A; Hu Q; Steglich D; Baier K; Wilbert J; Guckenberger M; Flentje M Radiat Oncol; 2008 Dec; 3():42. PubMed ID: 19087250 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]