252 related articles for article (PubMed ID: 19291981)
1. Optimizing the dynamic range extension of a radiochromic film dosimetry system.
Devic S; Tomic N; Soares CG; Podgorsak EB
Med Phys; 2009 Feb; 36(2):429-37. PubMed ID: 19291981
[TBL] [Abstract][Full Text] [Related]
2. Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies.
Chiu-Tsao ST; Ho Y; Shankar R; Wang L; Harrison LB
Med Phys; 2005 Nov; 32(11):3350-4. PubMed ID: 16370422
[TBL] [Abstract][Full Text] [Related]
3. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
Paelinck L; De Neve W; De Wagter C
Phys Med Biol; 2007 Jan; 52(1):231-42. PubMed ID: 17183138
[TBL] [Abstract][Full Text] [Related]
4. Multichannel film dosimetry with nonuniformity correction.
Micke A; Lewis DF; Yu X
Med Phys; 2011 May; 38(5):2523-34. PubMed ID: 21776787
[TBL] [Abstract][Full Text] [Related]
5. Precise radiochromic film dosimetry using a flat-bed document scanner.
Devic S; Seuntjens J; Sham E; Podgorsak EB; Schmidtlein CR; Kirov AS; Soares CG
Med Phys; 2005 Jul; 32(7):2245-53. PubMed ID: 16121579
[TBL] [Abstract][Full Text] [Related]
6. GafChromic EBT film dosimetry with flatbed CCD scanner: a novel background correction method and full dose uncertainty analysis.
Saur S; Frengen J
Med Phys; 2008 Jul; 35(7):3094-101. PubMed ID: 18697534
[TBL] [Abstract][Full Text] [Related]
7. A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT.
Andrés C; del Castillo A; Tortosa R; Alonso D; Barquero R
Med Phys; 2010 Dec; 37(12):6271-8. PubMed ID: 21302783
[TBL] [Abstract][Full Text] [Related]
8. Radiochromic film dosimetry of HDR (192)Ir source radiation fields.
Aldelaijan S; Mohammed H; Tomic N; Liang LH; Deblois F; Sarfehnia A; Abdel-Rahman W; Seuntjens J; Devic S
Med Phys; 2011 Nov; 38(11):6074-83. PubMed ID: 22047372
[TBL] [Abstract][Full Text] [Related]
9. A protocol for EBT3 radiochromic film dosimetry using reflection scanning.
Papaconstadopoulos P; Hegyi G; Seuntjens J; Devic S
Med Phys; 2014 Dec; 41(12):122101. PubMed ID: 25471974
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
Ferreira BC; Lopes MC; Capela M
Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
[TBL] [Abstract][Full Text] [Related]
11. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.
Lynch BD; Kozelka J; Ranade MK; Li JG; Simon WE; Dempsey JF
Med Phys; 2006 Dec; 33(12):4551-6. PubMed ID: 17278806
[TBL] [Abstract][Full Text] [Related]
12. Enhanced dosimetry procedures and assessment for EBT2 radiochromic film.
Mayer RR; Ma F; Chen Y; Miller RI; Belard A; McDonough J; O'Connell JJ
Med Phys; 2012 Apr; 39(4):2147-55. PubMed ID: 22482635
[TBL] [Abstract][Full Text] [Related]
13. Dose-response linearization in radiochromic film dosimetry based on multichannel normalized pixel value with an integrated spectral correction for scanner response variations.
Aldelaijan S; Devic S; Papaconstadopoulos P; Bekerat H; Cormack RA; Seuntjens J; Buzurovic IM
Med Phys; 2019 Nov; 46(11):5336-5349. PubMed ID: 31529516
[TBL] [Abstract][Full Text] [Related]
14. Post-irradiation colouration of Gafchromic EBT radiochromic film.
Cheung T; Butson MJ; Yu PK
Phys Med Biol; 2005 Oct; 50(20):N281-5. PubMed ID: 16204869
[TBL] [Abstract][Full Text] [Related]
15. A novel method of radiochromic film dosimetry using a color scanner.
Hupe O; Brunzendorf J
Med Phys; 2006 Nov; 33(11):4085-94. PubMed ID: 17153388
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.
Marroquin EY; Herrera González JA; Camacho López MA; Barajas JE; García-Garduño OA
J Appl Clin Med Phys; 2016 Sep; 17(5):466-481. PubMed ID: 27685125
[TBL] [Abstract][Full Text] [Related]
17. Linearization of dose-response curve of the radiochromic film dosimetry system.
Devic S; Tomic N; Aldelaijan S; Deblois F; Seuntjens J; Chan MF; Lewis D
Med Phys; 2012 Aug; 39(8):4850-7. PubMed ID: 22894411
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
Fuss M; Sturtewagen E; De Wagter C; Georg D
Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604
[TBL] [Abstract][Full Text] [Related]
19. Use of a control film piece in radiochromic film dosimetry.
Aldelaijan S; Alzorkany F; Moftah B; Buzurovic I; Seuntjens J; Tomic N; Devic S
Phys Med; 2016 Jan; 32(1):202-7. PubMed ID: 26740474
[TBL] [Abstract][Full Text] [Related]
20. Reference dosimetry during diagnostic CT examination using XR-QA radiochromic film model.
Boivin J; Tomic N; Fadlallah B; Deblois F; Devic S
Med Phys; 2011 Sep; 38(9):5119-29. PubMed ID: 21978057
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]