255 related articles for article (PubMed ID: 19291991)
1. Determination of correction factors for a 2D diode array device in MV photon beams.
Zhou X; Both S; Zhu TC
Med Phys; 2009 Feb; 36(2):523-9. PubMed ID: 19291991
[TBL] [Abstract][Full Text] [Related]
2. Backscatter correction factor for megavoltage photon beam.
Hu Y; Zhu TC
Med Phys; 2011 Oct; 38(10):5563-8. PubMed ID: 21992374
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.
Charland PM; Chetty IJ; Yokoyama S; Fraass BA
J Appl Clin Med Phys; 2003; 4(1):25-39. PubMed ID: 12540816
[TBL] [Abstract][Full Text] [Related]
4. Evaluating dosimetric accuracy of flattening filter free compensator-based IMRT: measurements with diode arrays.
Robinson J; Opp D; Zhang G; Cashon K; Kozelka J; Hunt D; Walker L; Hoffe S; Shridhar R; Feygelman V
Med Phys; 2012 Jan; 39(1):342-52. PubMed ID: 22225304
[TBL] [Abstract][Full Text] [Related]
5. Electron contamination in 8 and 18 MV photon beams.
Zhu TC; Palta JR
Med Phys; 1998 Jan; 25(1):12-9. PubMed ID: 9472821
[TBL] [Abstract][Full Text] [Related]
6. Influence of phantom material and phantom size on radiographic film response in therapy photon beams.
Palm A; LoSasso T
Med Phys; 2005 Aug; 32(8):2434-42. PubMed ID: 16193772
[TBL] [Abstract][Full Text] [Related]
7. The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams.
Araki F; Ohno T
Med Phys; 2014 Dec; 41(12):122102. PubMed ID: 25471975
[TBL] [Abstract][Full Text] [Related]
8. An analytical formalism to calculate phantom scatter factors for flattening filter free (FFF) mode photon beams.
Chung H; Prado KL; Yi BY
Phys Med Biol; 2014 Feb; 59(4):951-60. PubMed ID: 24503449
[TBL] [Abstract][Full Text] [Related]
9. Clinically relevant investigation of flattening filter-free skin dose.
Guy CL; Karki K; Sharma M; Kim S
J Appl Clin Med Phys; 2016 Nov; 17(6):140-148. PubMed ID: 27929489
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams.
Araki F
Phys Med Biol; 2012 Nov; 57(22):7615-27. PubMed ID: 23103477
[TBL] [Abstract][Full Text] [Related]
11. Dual ring multilayer ionization chamber and theory-based correction technique for scanning proton therapy.
Takayanagi T; Nihongi H; Nishiuchi H; Tadokoro M; Ito Y; Nakashima C; Fujitaka S; Umezawa M; Matsuda K; Sakae T; Terunuma T
Med Phys; 2016 Jul; 43(7):4150. PubMed ID: 27370135
[TBL] [Abstract][Full Text] [Related]
12. Differences in wedge factor determination in air using a PMMA mini-phantom or a brass build-up cap.
Heukelom S; Lanson JH; Mijnheer BJ
Med Phys; 1997 Dec; 24(12):1986-91. PubMed ID: 9434981
[TBL] [Abstract][Full Text] [Related]
13. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.
Chow JC; Grigorov GN
Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry.
Sabet M; Menk FW; Greer PB
Med Phys; 2010 Apr; 37(4):1459-67. PubMed ID: 20443467
[TBL] [Abstract][Full Text] [Related]
15. Dosimetry of 24-MV x rays from a linear accelerator.
Krithivas G; Rao SN
Med Phys; 1987; 14(2):274-81. PubMed ID: 3587155
[TBL] [Abstract][Full Text] [Related]
16. Wedge factor constituents of high-energy photon beams: head and phantom scatter dose components.
Heukelom S; Lanson JH; Mijnheer BJ
Radiother Oncol; 1994 Jul; 32(1):73-83. PubMed ID: 7938681
[TBL] [Abstract][Full Text] [Related]
17. The water equivalence of solid phantoms for low energy photon beams.
Hill R; Kuncic Z; Baldock C
Med Phys; 2010 Aug; 37(8):4355-63. PubMed ID: 20879595
[TBL] [Abstract][Full Text] [Related]
18. Influence of phantom thickness and material on the backscatter factors for diagnostic x-ray beam dosimetry.
Benmakhlouf H; Fransson A; Andreo P
Phys Med Biol; 2013 Jan; 58(2):247-60. PubMed ID: 23257169
[TBL] [Abstract][Full Text] [Related]
19. In phantom determination of collimator scatter factor.
Lam KL; Ten Haken RK
Med Phys; 1996 Jul; 23(7):1207-12. PubMed ID: 8839414
[TBL] [Abstract][Full Text] [Related]
20. Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy.
Chofor N; Harder D; Poppe B
Z Med Phys; 2012 Sep; 22(3):181-96. PubMed ID: 22658451
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]