BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 19293468)

  • 1. The angular dependence and effective point of measurement of a cylindrical scintillation dosimeter with and without a radio-opaque marker for brachytherapy.
    Cartwright LE; Lambert J; McKenzie DR; Suchowerska N
    Phys Med Biol; 2009 Apr; 54(7):2217-27. PubMed ID: 19293468
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A plastic scintillation dosimeter for high dose rate brachytherapy.
    Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
    Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A scintillation dosimeter with real-time positional tracking information for in vivo dosimetry error detection in HDR brachytherapy.
    Tho D; Lavallée MC; Beaulieu L
    J Appl Clin Med Phys; 2023 Dec; 24(12):e14150. PubMed ID: 37731203
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time monitoring and diagnosis of scintillation dosimeters using an ultraviolet light emitting diode.
    Yin Y; Lambert J; McKenzie DR; Suchowerska N
    Phys Med Biol; 2008 May; 53(9):2303-12. PubMed ID: 18401065
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric performance of a multipoint plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate
    Linares Rosales HM; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2020 Sep; 47(9):4477-4490. PubMed ID: 32443175
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode.
    Ishikawa M; Bengua G; Sutherland KL; Hiratsuka J; Katoh N; Shimizu S; Aoyama H; Fujita K; Yamazaki R; Horita K; Shirato H
    Phys Med Biol; 2009 Apr; 54(7):2079-92. PubMed ID: 19287089
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.
    Tho D; Beaulieu L
    Med Phys; 2019 May; 46(5):2031-2036. PubMed ID: 30919450
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fibre optic scintillator dosemeter for absorbed dose measurements of low-energy X-ray-emitting brachytherapy sources.
    Sliski A; Soares C; Mitch MG
    Radiat Prot Dosimetry; 2006; 120(1-4):24-7. PubMed ID: 16782747
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radio-physical properties of micelle leucodye 3D integrating gel dosimeters.
    Vandecasteele J; Ghysel S; Baete SH; De Deene Y
    Phys Med Biol; 2011 Feb; 56(3):627-51. PubMed ID: 21220844
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An experimental MOSFET approach to characterize (192)Ir HDR source anisotropy.
    Toye WC; Das KR; Todd SP; Kenny MB; Franich RD; Johnston PN
    Phys Med Biol; 2007 Sep; 52(17):5329-39. PubMed ID: 17762089
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Scintillation dosimeter arrays using air core light guides: simulation and experiment.
    Naseri P; Suchowerska N; McKenzie DR
    Phys Med Biol; 2010 Jun; 55(12):3401-15. PubMed ID: 20505222
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo validation and optimisation of detector packaging for spectroscopic dosimetry for in vivo urethral dosimetry during low dose rate brachytherapy.
    Nourbehesht LK; Cutajar DL; Guatelli S; Rosenfeld AB
    Australas Phys Eng Sci Med; 2015 Sep; 38(3):455-63. PubMed ID: 26239932
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.
    Ishikawa M; Nagase N; Matsuura T; Hiratsuka J; Suzuki R; Miyamoto N; Sutherland KL; Fujita K; Shirato H
    J Radiat Res; 2015 Mar; 56(2):372-81. PubMed ID: 25618136
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
    Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A self-checking fiber optic dosimeter for monitoring common errors in brachytherapy applications.
    Yin Y; Lambert J; Yang S; McKenzie DR; Jackson M; Suchowerska N
    Med Phys; 2009 Jul; 36(7):2985-91. PubMed ID: 19673197
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technical note: Angular dependence in fiber optic dosimetry using YVO
    Martínez N; Fernández Y; Machello S; Molina P; Massa J; Santiago M
    Med Phys; 2023 Jul; 50(7):4645-4650. PubMed ID: 36971394
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric evaluation of a new OneDose MOSFET for Ir-192 energy.
    Kinhikar RA; Sharma PK; Tambe CM; Deshpande DD
    Phys Med Biol; 2006 Mar; 51(5):1261-8. PubMed ID: 16481692
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Towards two-dimensional brachytherapy dosimetry using plastic scintillator: new highly efficient water equivalent plastic scintillator materials.
    Kirov AS; Hurlbut C; Dempsey JF; Shrinivas SB; Epstein JW; Binns WR; Dowkontt PF; Williamson JF
    Med Phys; 1999 Aug; 26(8):1515-23. PubMed ID: 10501051
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental evaluation of a MOSFET dosimeter for proton dose measurements.
    Kohno R; Nishio T; Miyagishi T; Hirano E; Hotta K; Kawashima M; Ogino T
    Phys Med Biol; 2006 Dec; 51(23):6077-86. PubMed ID: 17110771
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.
    Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N
    Phys Med Biol; 2008 Jun; 53(11):3071-80. PubMed ID: 18490811
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.