159 related articles for article (PubMed ID: 19293468)
1. The angular dependence and effective point of measurement of a cylindrical scintillation dosimeter with and without a radio-opaque marker for brachytherapy.
Cartwright LE; Lambert J; McKenzie DR; Suchowerska N
Phys Med Biol; 2009 Apr; 54(7):2217-27. PubMed ID: 19293468
[TBL] [Abstract][Full Text] [Related]
2. A plastic scintillation dosimeter for high dose rate brachytherapy.
Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
[TBL] [Abstract][Full Text] [Related]
3. A scintillation dosimeter with real-time positional tracking information for in vivo dosimetry error detection in HDR brachytherapy.
Tho D; Lavallée MC; Beaulieu L
J Appl Clin Med Phys; 2023 Dec; 24(12):e14150. PubMed ID: 37731203
[TBL] [Abstract][Full Text] [Related]
4. Real-time monitoring and diagnosis of scintillation dosimeters using an ultraviolet light emitting diode.
Yin Y; Lambert J; McKenzie DR; Suchowerska N
Phys Med Biol; 2008 May; 53(9):2303-12. PubMed ID: 18401065
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric performance of a multipoint plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate
Linares Rosales HM; Archambault L; Beddar S; Beaulieu L
Med Phys; 2020 Sep; 47(9):4477-4490. PubMed ID: 32443175
[TBL] [Abstract][Full Text] [Related]
6. A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode.
Ishikawa M; Bengua G; Sutherland KL; Hiratsuka J; Katoh N; Shimizu S; Aoyama H; Fujita K; Yamazaki R; Horita K; Shirato H
Phys Med Biol; 2009 Apr; 54(7):2079-92. PubMed ID: 19287089
[TBL] [Abstract][Full Text] [Related]
7. Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.
Tho D; Beaulieu L
Med Phys; 2019 May; 46(5):2031-2036. PubMed ID: 30919450
[TBL] [Abstract][Full Text] [Related]
8. A fibre optic scintillator dosemeter for absorbed dose measurements of low-energy X-ray-emitting brachytherapy sources.
Sliski A; Soares C; Mitch MG
Radiat Prot Dosimetry; 2006; 120(1-4):24-7. PubMed ID: 16782747
[TBL] [Abstract][Full Text] [Related]
9. Radio-physical properties of micelle leucodye 3D integrating gel dosimeters.
Vandecasteele J; Ghysel S; Baete SH; De Deene Y
Phys Med Biol; 2011 Feb; 56(3):627-51. PubMed ID: 21220844
[TBL] [Abstract][Full Text] [Related]
10. An experimental MOSFET approach to characterize (192)Ir HDR source anisotropy.
Toye WC; Das KR; Todd SP; Kenny MB; Franich RD; Johnston PN
Phys Med Biol; 2007 Sep; 52(17):5329-39. PubMed ID: 17762089
[TBL] [Abstract][Full Text] [Related]
11. Scintillation dosimeter arrays using air core light guides: simulation and experiment.
Naseri P; Suchowerska N; McKenzie DR
Phys Med Biol; 2010 Jun; 55(12):3401-15. PubMed ID: 20505222
[TBL] [Abstract][Full Text] [Related]
12. Monte Carlo validation and optimisation of detector packaging for spectroscopic dosimetry for in vivo urethral dosimetry during low dose rate brachytherapy.
Nourbehesht LK; Cutajar DL; Guatelli S; Rosenfeld AB
Australas Phys Eng Sci Med; 2015 Sep; 38(3):455-63. PubMed ID: 26239932
[TBL] [Abstract][Full Text] [Related]
13. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.
Ishikawa M; Nagase N; Matsuura T; Hiratsuka J; Suzuki R; Miyamoto N; Sutherland KL; Fujita K; Shirato H
J Radiat Res; 2015 Mar; 56(2):372-81. PubMed ID: 25618136
[TBL] [Abstract][Full Text] [Related]
14. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
[TBL] [Abstract][Full Text] [Related]
15. A self-checking fiber optic dosimeter for monitoring common errors in brachytherapy applications.
Yin Y; Lambert J; Yang S; McKenzie DR; Jackson M; Suchowerska N
Med Phys; 2009 Jul; 36(7):2985-91. PubMed ID: 19673197
[TBL] [Abstract][Full Text] [Related]
16. Technical note: Angular dependence in fiber optic dosimetry using YVO
Martínez N; Fernández Y; Machello S; Molina P; Massa J; Santiago M
Med Phys; 2023 Jul; 50(7):4645-4650. PubMed ID: 36971394
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric evaluation of a new OneDose MOSFET for Ir-192 energy.
Kinhikar RA; Sharma PK; Tambe CM; Deshpande DD
Phys Med Biol; 2006 Mar; 51(5):1261-8. PubMed ID: 16481692
[TBL] [Abstract][Full Text] [Related]
18. Towards two-dimensional brachytherapy dosimetry using plastic scintillator: new highly efficient water equivalent plastic scintillator materials.
Kirov AS; Hurlbut C; Dempsey JF; Shrinivas SB; Epstein JW; Binns WR; Dowkontt PF; Williamson JF
Med Phys; 1999 Aug; 26(8):1515-23. PubMed ID: 10501051
[TBL] [Abstract][Full Text] [Related]
19. Experimental evaluation of a MOSFET dosimeter for proton dose measurements.
Kohno R; Nishio T; Miyagishi T; Hirano E; Hotta K; Kawashima M; Ogino T
Phys Med Biol; 2006 Dec; 51(23):6077-86. PubMed ID: 17110771
[TBL] [Abstract][Full Text] [Related]
20. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.
Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N
Phys Med Biol; 2008 Jun; 53(11):3071-80. PubMed ID: 18490811
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]