These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
103 related articles for article (PubMed ID: 19297232)
1. Influence of the orientation of the Osstell transducer during measurement of dental implant stability using resonance frequency analysis: a numerical approach. Capek L; Simunek A; Slezak R; Dzan L Med Eng Phys; 2009 Sep; 31(7):764-9. PubMed ID: 19297232 [TBL] [Abstract][Full Text] [Related]
2. Influence of transducer orientation on Osstell stability measurements of osseointegrated implants. Veltri M; Balleri P; Ferrari M Clin Implant Dent Relat Res; 2007 Mar; 9(1):60-4. PubMed ID: 17362497 [TBL] [Abstract][Full Text] [Related]
3. Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer. Pattijn V; Jaecques SV; De Smet E; Muraru L; Van Lierde C; Van der Perre G; Naert I; Vander Sloten J Med Eng Phys; 2007 Mar; 29(2):182-90. PubMed ID: 16597507 [TBL] [Abstract][Full Text] [Related]
4. The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach. Pattijn V; Van Lierde C; Van der Perre G; Naert I; Vander Sloten J J Biomech; 2006; 39(5):939-47. PubMed ID: 16488232 [TBL] [Abstract][Full Text] [Related]
5. Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants. Sul YT; Jönsson J; Yoon GS; Johansson C Clin Oral Implants Res; 2009 Oct; 20(10):1146-55. PubMed ID: 19719742 [TBL] [Abstract][Full Text] [Related]
6. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Zix J; Hug S; Kessler-Liechti G; Mericske-Stern R Int J Oral Maxillofac Implants; 2008; 23(3):525-30. PubMed ID: 18700378 [TBL] [Abstract][Full Text] [Related]
7. Influence of osseointegration degree and pattern on resonance frequency in the assessment of dental implant stability using finite element analysis. Deng B; Tan KB; Liu GR; Lu Y Int J Oral Maxillofac Implants; 2008; 23(6):1082-8. PubMed ID: 19216277 [TBL] [Abstract][Full Text] [Related]
8. Combined influence of implant diameter and alveolar ridge width on crestal bone stress: a quantitative approach. Yu W; Jang YJ; Kyung HM Int J Oral Maxillofac Implants; 2009; 24(1):88-95. PubMed ID: 19344030 [TBL] [Abstract][Full Text] [Related]
9. Comparative analysis of 2 resonance frequency measurement devices: Osstell Mentor and Osstell ISQ. Jaramillo R; Santos R; Lázaro P; Romero M; Rios-Santos JV; Bullón P; Fernández-Palacín A; Herrero-Climent M Implant Dent; 2014 Jun; 23(3):351-6. PubMed ID: 24776942 [TBL] [Abstract][Full Text] [Related]
10. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis. Ding X; Zhu XH; Liao SH; Zhang XH; Chen H J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710 [TBL] [Abstract][Full Text] [Related]
11. Biomechanics of the mandible part I: measurement of mandibular functional deformation using custom-fabricated displacement transducers. Al-Sukhun J; Helenius M; Lindqvist C; Kelleway J J Oral Maxillofac Surg; 2006 Jul; 64(7):1015-22. PubMed ID: 16781333 [TBL] [Abstract][Full Text] [Related]
12. Effect of macro-design of immediately loaded implants on micromotion and stress distribution in surrounding bone using finite element analysis. Fazel A; Aalai S; Rismanchian M Implant Dent; 2009 Aug; 18(4):345-52. PubMed ID: 19667823 [TBL] [Abstract][Full Text] [Related]
13. Finite element stress analysis of dental prostheses supported by straight and angled implants. Cruz M; Wassall T; Toledo EM; da Silva Barra LP; Cruz S Int J Oral Maxillofac Implants; 2009; 24(3):391-403. PubMed ID: 19587860 [TBL] [Abstract][Full Text] [Related]
14. Marginal bone stability using 3 different flap approaches for alveolar split expansion for dental implants: a 1-year clinical study. Jensen OT; Cullum DR; Baer D J Oral Maxillofac Surg; 2009 Sep; 67(9):1921-30. PubMed ID: 19686930 [TBL] [Abstract][Full Text] [Related]
15. Effect of platform switching on implant crest bone stress: a finite element analysis. Schrotenboer J; Tsao YP; Kinariwala V; Wang HL Implant Dent; 2009 Jun; 18(3):260-9. PubMed ID: 19509536 [TBL] [Abstract][Full Text] [Related]
16. Biomechanical aspects of bone-level diameter shifting at implant-abutment interface. Canay S; Akça K Implant Dent; 2009 Jun; 18(3):239-48. PubMed ID: 19509534 [TBL] [Abstract][Full Text] [Related]
17. Subject specific finite element analysis of implant stability for a cementless femoral stem. Pettersen SH; Wik TS; Skallerud B Clin Biomech (Bristol); 2009 Jul; 24(6):480-7. PubMed ID: 19368993 [TBL] [Abstract][Full Text] [Related]
18. Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants. Eser A; Akça K; Eckert S; Cehreli MC Int J Oral Maxillofac Implants; 2009; 24(3):439-46. PubMed ID: 19587865 [TBL] [Abstract][Full Text] [Related]
19. Influence of loading frequency on implant failure under cyclic fatigue conditions. Karl M; Kelly JR Dent Mater; 2009 Nov; 25(11):1426-32. PubMed ID: 19643468 [TBL] [Abstract][Full Text] [Related]
20. Correlating implant stability to bone structure. Rozé J; Babu S; Saffarzadeh A; Gayet-Delacroix M; Hoornaert A; Layrolle P Clin Oral Implants Res; 2009 Oct; 20(10):1140-5. PubMed ID: 19519789 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]